4121 matches found
Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞
The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from the inclusion of hard-coded credentials used to access...
CVE-2024-48123
An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...
CVE-2024-48126
HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...
CVE-2024-48122
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...
CVE-2024-48122
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges...
CVE-2024-48123
The CVE-2024-48123 entry concerns the HI-SCAN 6040i Hitrax HX-03-19-I's USB Autorun feature. The vulnerability enables attackers to execute arbitrary code by uploading a crafted script from a USB device. Current connected documents reiterate this issue but do not provide specific affected version...
Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞
The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I, which stems from an issue in the AsDB service that allows an attacker to...
CVE-2024-48125
CVE-2024-48125 affects the HI-SCAN 6040i Hitrax HX-03-19-I system via the AsDB service. The issue allows an attacker to enumerate user credentials by sending crafted GIOP protocol requests. Documented impact is credential enumeration with a base CVSS v3.1 score of 7.5 (High) and network access wi...
CVE-2024-48126
HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access...
CVE-2024-48125
An issue in the AsDB service of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to enumerate user credentials via crafted GIOP protocol requests...
CVE-2024-48122
CVE-2024-48122 concerns the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I, where insecure default configurations enable an authenticated attacker with low privileges to escalate to root. The connected sources consistently describe the issue as an insecure default setup that permits local privi...
Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞
The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from an insecure default configuration that allows an...
PT-2025-2792 · Unknown · Hi-Scan 6040I
Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I Description: The issue concerns hardcoded credentials in the system, which could allow unauthorized access to vendor support and service access. Recommendations: For HI-SCAN 6040i Hitrax HX-03-19-I, consider...
CVE-2024-48123
An issue in the USB Autorun function of HI-SCAN 6040i Hitrax HX-03-19-I allows attackers to execute arbitrary code via uploading a crafted script from a USB device...
CVE-2024-48121
The CVE-2024-48121 entry concerns the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I. Affected component: the HI-SCAN 6040i system; issue: credentials are transmitted in cleartext over the GIOP protocol, enabling potential man-in-the-middle access to sensitive information. Impact is described a...
Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I 安全漏洞
The Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I is an entry-level X-ray equipment electronic component from Smiths Detection, UK. A security vulnerability exists in the Smiths Detection HI-SCAN 6040i Hitrax HX-03-19-I that stems from a problem with the USB autorun feature...
CVE-2024-48121
The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack...
February 4, 2025, update for Access 2016 (KB5002688)
February 4, 2025, update for Access 2016 KB5002688 This article describes update 5002688 for Microsoft Access 2016 that was released on February 4, 2025.Be aware that the update in the Microsoft Download Center applies to the Microsoft Installer .msi-based edition of Office 2016. It doesn't apply...
Enumerate the Microsoft Windows Registry
Using the supplied credentials, Nessus was unable to log into the remote Windows host, enumerate registry keys and values required for vulnerability scans and store them in the knowledge base for other plugins to use. %NASLMINLEVEL 70300 C Tenable Network Security, Inc...
CVE-2025-22583
Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in anshulsojatia Scan External Links scan-external-links allows Reflected XSS.This issue affects Scan External Links: from n/a through = 1.0...