12 matches found
Siemens SCALANCE S613 Denial of Service (CVE-2016-3963)
Siemens SCALANCE S613 allows remote attackers to cause a denial of service web-server outage via traffic to TCP port 443. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc';...
Siemens SCALANCE S613 Security module
Binary data 751134.prm...
Siemens SCALANCE S613 Denial of Service
Binary data 720080.prm...
Siemens SCALANCE S613 Denial Of Service
Exploit Title: Siemens SCALANCE S613 - Remote Denial-of-Service Vulnerability Date: 2018-05-23 Exploit Author: t4rkd3vilz Vendor Homepage: https://www.siemens.com/ Version: SCALANCE S613 MLFB: 6GK5613-0BA00-2AA3: All versions. Tested on: Kali Linux CVE: CVE-2016-3963 !/usr/bin/python import socke...
Siemens SCALANCE S613 - Remote Denial of Service
Exploit Title: Siemens SCALANCE S613 - Remote Denial of Service Date: 2018-05-23 Exploit Author: t4rkd3vilz Vendor Homepage: https://www.siemens.com/ Version: SCALANCE S613 MLFB: 6GK5613-0BA00-2AA3: All versions. Tested on: Kali Linux CVE: CVE-2016-3963 !/usr/bin/python import socket import sys i...
Siemens SCALANCE S613 Denial of Service Vulnerability
SCALANCES firewalls are network security protection products. A denial of service vulnerability exists in the Siemens SCALANCE S613, where an unauthenticated, remote attacker sending packets to TCP port 443 can cause a denial of service to the web server...
CVE-2016-3963
Siemens SCALANCE S613 allows remote attackers to cause a denial of service web-server outage via traffic to TCP port 443...
Design/Logic Flaw
Siemens SCALANCE S613 allows remote attackers to cause a denial of service web-server outage via traffic to TCP port 443...
CVE-2016-3963
Siemens SCALANCE S613 allows remote attackers to cause a denial of service web-server outage via traffic to TCP port 443...
CVE-2016-3963
Siemens SCALANCE S613 is affected by CVE-2016-3963. A remote attacker can cause a denial of service (web-server outage) by sending crafted traffic to TCP port 443, impacting availability. The root cause/patch details are not provided in the supplied documents; refer to linked advisories/exploits ...
Siemens SCALANCE S613 Denial-of-Service Vulnerability
OVERVIEW Siemens has identified a resource exhaustion vulnerability that causes a denial-of-service condition in the Siemens SCALANCE S613 device. Siemens recommends that customers contact Siemens customer support in order to obtain advice on a solution for the customer’s specific environment. Th...
Stack overflow
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service device outage or possibly execute arbitrary code via a crafted...