3461 matches found
Path traversal
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-1437
Advantech WebAccess/SCADA (all versions prior to 9.1.4) is affected by CVE-2023-1437 due to untrusted pointer handling in RPC arguments, enabling a remote attacker to access the remote file system and potentially execute commands or overwrite files. The root cause is untrusted pointers dereferenc...
CVE-2023-1437 CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
CVE-2023-3329
CVE-2023-3329 affects SpiderControl SCADA Webserver versions 2.08 and prior. The vulnerability is a path traversal (CWE-22) flaw in the HMI file upload feature, allowing an attacker with administrative privileges to overwrite files on the webserver, potentially creating size-zero files anywhere a...
CVE-2023-3329 CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-3329 CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
Advantech WebAccess/SCADA Buffer Error Vulnerability
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, China. The software supports dynamic graphical display and real-time data control, and provides remote control and management of automation devices. A buffer error vulnerability exists in Advantech...
The vulnerability of the SpiderControl SCADA Web Server arises from an incorrect restriction on the path to the restricted access catalog. This allows a intruder to cause a service failure.
The vulnerability of the SpiderControl SCADA Web Server exists due to an incorrect restriction on the path to the restricted catalog. Exploiting this vulnerability could allow a malicious actor to cause service failures...
PT-2023-4939 · Advantech · Webaccess/Scada
Name of the Vulnerable Software and Affected Versions: Advantech WebAccess/SCADA versions prior to 9.1.4 Description: The issue is related to the use of untrusted pointers in the software. Specifically, the RPC arguments sent by the client could contain raw memory pointers that the server uses...
The vulnerability of the software and hardware components of SCADA systems, such as the ABB Pulsar Plus System Controller NE843_S, Infinity DC Power Plant H5692448 G104, Infinity DC Power Plant H5692448 G842, Infinity DC Power Plant H5692448 G224L, Infinity DC Power Plant H5692448 G630-4, Infinity DC Power Plant H5692448 G451C(2), Infinity DC Power Plant H5692448 G461(2), arises due to insufficient validation of input data. This vulnerability allows attackers to execute CSRF attacks.
The vulnerabilities of the software and hardware components of SCADA systems, such as ABB Pulsar Plus System Controller NE843S, Infinity DC Power Plant H5692448 G104, Infinity DC Power Plant H5692448 G842, Infinity DC Power Plant H5692448 G224L, Infinity DC Power Plant H5692448 G630-4, Infinity D...
CISA Releases Four Industrial Control Systems Advisories
CISA released four Industrial Control Systems ICS advisories on June 22, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-173-02 Advantech R-SeeNet ICSA-23-173-03 SpiderControl SCADAWebServer ICSA-23-026-02...
The vulnerability of the DashBoard.exe executable file of the Dashboard module in the Interactive Graphical SCADA System (IGSS) allows a intruder to execute arbitrary code.
The vulnerability of the DashBoard.exe executable file of the Dashboard module in the Interactive Graphical SCADA System IGSS is related to deficiencies in the deserialization mechanism. Exploiting this vulnerability could allow an attacker to execute arbitrary code...
Advantech WebAccess/SCADA
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WebAccess/SCADA Vulnerability: Untrusted Pointer Dereference 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker gaining remote file system...
Siemens SIMATIC WinCC Local Code Execution Vulnerability
SIMATIC WinCC is a supervisory control and data acquisition SCADA system. A local code execution vulnerability exists in Siemens SIMATIC WinCC, which can be exploited by an attacker to inject arbitrary code and escalate privileges...
Siemens SIMATIC WinCC using obsolete function vulnerability
SIMATIC NET PC software is a separately sold software product that implements the SIMATIC NET communication products.SIMATIC PCS 7 is a centralized control system DCS that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components.SIMATIC WinCC is a Supervisory...
Triangle MicroWorks SCADA Data Gateway WebMonitor Broadcasts Arbitrary Events Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. An arbitrary user broadcast event vulnerability exists in the Triangle MicroWorks SCADA Data Gateway WebMonitor, which can be exploited by a remote attacker to submit a special request that can...
The vulnerability of the executable file GTWWebMonitor.exe in the SCADA system SCADA Data Gateway allows a intruder to trigger a service failure or execute arbitrary code.
The vulnerability of the GTWWebMonitor.exe executable in the SCADA system SCADA Data Gateway is related to the use of uncontrolled format strings. Exploiting this vulnerability could allow a malicious actor to cause service interruptions or execute arbitrary code by sending specially crafted...
The vulnerability of the Advantech WebAccss/SCADA SCADA system, related to the unlimited loading of dangerous type files, allows a intruder to execute arbitrary code.
The vulnerability of the Advantech WebAccss/SCADA SCADA system is related to the unlimited loading of dangerous files. Exploiting this vulnerability allows a malicious actor to execute arbitrary code remotely...
Triangle MicroWorks SCADA Data Gateway Formatting String Error Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. A formatting string error vulnerability exists in Triangle MicroWorks SCADA Data Gateway, which can be exploited by an attacker to execute arbitrary code and gain host privileges...
CVE-2023-2866
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server...