3460 matches found
CVE-2024-21866
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product responds back with an error message containing sensitive data if it receives a specific malformed request...
CVE-2024-21869
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product stores plaintext credentials in various places. This may allow an attacker with local access to see them...
CVE-2024-22096
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can append path traversal characters to the filename when using a specific command, allowing them to read arbitrary files from the system...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
CVE-2023-2866
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server...
CVE-2023-22610
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port...
CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-30459
SmartPTT SCADA 1.1.0.0 allows remote code execution when the attacker has administrator privileges by writing a malicious C script and executing it on the server via server settings in the administrator control panel on port 8101, by default...
CVE-2023-22611
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...
CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
CVE-2023-33472
An issue was discovered in Scada-LTS v2.7.5.2 build 4551883606 and before, allows remote attackers with low-level authentication to escalate privileges, execute arbitrary code, and obtain sensitive information via Event Handlers function...
CVE-2023-2187
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event"...
CVE-2023-2186
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string...
CVE-2022-25359
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files...
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
CVE-2022-44153
Rapid Software LLC Rapid SCADA 5.8.4 is vulnerable to Cross Site Scripting XSS...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...