Lucene search
+L

3468 matches found

CVE
CVE
added 2012/08/19 8:0 p.m.60 views

CVE-2012-4356

CVE-2012-4356 describes multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA (pre-2.07.17) and Winlog Lite SCADA (pre-2.07.17) . The flaw allows a remote attacker to read arbitrary files by sending crafted TCP packets to port 46824, issuing a file-open operation (opcode...

4.3CVSS7AI score0.27488EPSS
SaveExploits4References4Affected Software1
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.36 views

CVE-2012-4353

Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the TCPIPSBinOpenFileFP function,...

7.7AI score0.24795EPSS
SaveExploits2References4
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.34 views

CVE-2012-4356

Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. dot dot in a pathname, followed ...

6.8AI score0.27488EPSS
SaveExploits4References4
CVE
CVE
added 2012/08/19 8:0 p.m.48 views

CVE-2012-4357

CVE-2012-4357 describes an array index error in Sielco Sistemi Winlog Pro SCADA (before 2.07.17) and Winlog Lite SCADA (before 2.07.17) that enables remote code execution. An attacker can reference an invalid file-pointer index within a port-46824 TCP packet, triggering execution of an EnterCriti...

9.3CVSS7.9AI score0.07351EPSS
SaveExploits2References4Affected Software1
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.37 views

CVE-2012-4354

TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted positive integer after the opcode, triggering incorrect function-pointer processing that can lead to ...

7.5AI score0.08186EPSS
SaveExploits2References4
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.33 views

CVE-2012-4359

Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service invalid 0x00 write operation and daemon crash or possibly have unspecified other impact via a...

7.4AI score0.0252EPSS
SaveExploits1References4
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.35 views

CVE-2012-4357

Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might allow remote attackers to execute arbitrary code by referencing, within a port-46824 TCP packet, an invalid file-pointer index that leads to execution of an EnterCriticalSection code blo...

7.7AI score0.07351EPSS
SaveExploits2References4
CVE
CVE
added 2012/08/19 8:0 p.m.66 views

CVE-2012-4358

Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 (and related 2.07.18 variants) are affected by a vulnerability where the realloc return value is not validated. This can allow remote attackers to cause a denial of service (invalid 0x00 write operation and daemon...

9.3CVSS7.5AI score0.0252EPSS
SaveExploits1References4Affected Software1
CVE
CVE
added 2012/08/19 8:0 p.m.51 views

CVE-2012-4353

CVE-2012-4353 is a stack-based buffer overflow in RunTime.exe of Sielco Sistemi Winlog Pro SCADA (before 2.07.17) and Winlog Lite SCADA (before 2.07.17). A remote attacker can trigger arbitrary code execution by sending a crafted TCP packet to port 46824, causing an incorrect file-open by the _TC...

9.3CVSS8AI score0.24795EPSS
SaveExploits2References4Affected Software1
CVE
CVE
added 2012/08/19 8:0 p.m.55 views

CVE-2012-4359

Summary (CVE-2012-4359): Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 fail to validate the return value of realloc, enabling a remote attacker to cause a denial of service (invalid 0x00 write) and daemon crash. This may occur via a port-46824 TCP packet cont...

9.3CVSS7.6AI score0.0252EPSS
SaveExploits1References4Affected Software1
CVE
CVE
added 2012/08/19 8:0 p.m.69 views

CVE-2012-4354

CVE-2012-4354 affects TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA (before 2.07.17) and Winlog Lite SCADA (before 2.07.17). The vulnerability arises from a port-46824 TCP packet containing a crafted positive integer after the opcode, which triggers incorrect function-pointer processing and...

9.3CVSS7.8AI score0.08186EPSS
SaveExploits2References4Affected Software1
Cvelist
Cvelist
added 2012/08/19 8:0 p.m.34 views

CVE-2012-4355

TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted negative integer after the opcode, triggering incorrect function-pointer processing that can lead to ...

7.6AI score0.08186EPSS
SaveExploits2References4
CVE
CVE
added 2012/08/19 8:0 p.m.57 views

CVE-2012-4355

Summary (CVE-2012-4355) : TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA <2.07.18 and Winlog Lite SCADA

9.3CVSS7.9AI score0.08186EPSS
SaveExploits2References4Affected Software1
Tenable Nessus
Tenable Nessus
added 2012/08/16 12:0 a.m.12 views

enteliTOUCH SCADA Server Detection

Binary data 6542.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2012/08/16 12:0 a.m.15 views

Electro Industries GaugeTech SCADA Server Detection

Binary data 6543.prm...

7.3AI score
SaveExploits0
ThreatPost
ThreatPost
added 2012/07/24 3:33 p.m.14 views

Siemens Patches Stuxnet-Like SCADA Bugs

German industrial control system manufacturer Siemens announced Monday that it had patched holes in some of its products that appear to resemble holes used by the famous Stuxnet worm in 2010. If left unpatched, vulnerabilities in the company’s Simatic STEP 7 and Simatic PCS 7 software could have...

0.8AI score
SaveExploits0References5
ThreatPost
ThreatPost
added 2012/07/24 3:31 p.m.13 views

Siemens Patches Stuxnet-Like SCADA Bugs

German industrial control system manufacturer Siemens announced Monday that it had patched holes in some of its products that appear to resemble holes used by the popular Stuxnet worm in 2010. If left unpatched, vulnerabilities in the company’s Simatic STEP 7 and Simatic PCS 7 software could have...

0.7AI score
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2012/07/06 12:0 a.m.22 views

WellinTech KingHistorian Detection

Binary data scadaappwellintechkinghistoriandetect.nbin...

7.3AI score
SaveExploits0References1
NVD
NVD
added 2012/07/05 3:23 a.m.33 views

CVE-2012-2515

Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module aka the HTML Help component, as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1...

9.3CVSS7.7AI score0.27595EPSS
SaveExploits2References8
CVE
CVE
added 2012/07/05 1:0 a.m.206 views

CVE-2012-2516

The CVE-2012-2516 issue is an ActiveX-based command-injection vulnerability in KeyHelp.ocx of GE Intelligent Platforms’ KeyWorks KeyHelp module, affecting Proficy Historian (3.1, 3.5, 4.0, 4.5), Proficy HMI/SCADA – iFIX (5.0, 5.1), Proficy Pulse 1.0, Proficy Batch Execution 5.6, and SI7 I/O Drive...

9.3CVSS7.7AI score0.39711EPSS
SaveExploits9References2Affected Software5
Rows per page
Query Builder