Lucene search
+L

3468 matches found

ThreatPost
ThreatPost
added 2014/12/24 9:55 a.m.15 views

HP's Zero Day Initiative Changes Bug-Buying Guidelines

HP’s Zero Day Initiative has decided to adjust its guidelines and criteria or buying some vulnerabilities in the future, eliminating some large classes of bugs from its menu. The group, which has been among the more visible and prominent of the vulnerability purchasing programs since its inceptio...

1.6AI score
SaveExploits0References2
myhack58
myhack58
added 2014/12/18 12:0 a.m.27 views

Industrial safety: BlackEnergy(dark)the use of the Siemens WinCC system has been repaired loopholes to launch attacks-vulnerability warning-the black bar safety net

Researchers recently found that the malware BlackEnergy(dark forces are using Siemens SIMATIC WinCC(Siemens the most classic process monitoring system has been repaired loopholes to re-attack the SCADA HMI system. ! Comeback: the BlackEnergy then update the BlackEnergy(dark)is an automated networ...

2.7AI score
SaveExploits0
Packet Storm
Packet Storm
added 2014/12/15 12:0 a.m.53 views

Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass

Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit Vendor: Soitec Product web page: http://www.soitec.com Affected version: 1.4 and 1.3 Summary: Soitec power plants are a profitable and ecological investment at the same time. Using Concentrix technology, Soitec offers...

1.2AI score
SaveExploits0
exploitpack
exploitpack
added 2014/12/15 12:0 a.m.48 views

Soitec SmartEnergy 1.4 - SCADA Login SQL Injection Authentication Bypass

Soitec SmartEnergy 1.4 - SCADA Login SQL Injection Authentication Bypass Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit Vendor: Soitec Product web page: http://www.soitec.com Affected version: 1.4 and 1.3 Summary: Soitec power plants are a profitable and ecological...

1.2AI score
SaveExploits0
zdt
zdt
added 2014/12/15 12:0 a.m.52 views

Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit

Soitec SmartEnergy web application suffers from an authentication bypass vulnerability using SQL Injection attack in the login script. The script fails to sanitize the 'login' POST parameter allowing the attacker to bypass the security mechanism and view sensitive information that can be further...

7.7AI score
SaveExploits0
ICS
ICS
added 2014/12/14 7:0 a.m.43 views

Schneider Electric StruxureWare SCADA Expert ClearSCADA Parsing Vulnerability

OVERVIEW Andrew Brooks identified and reported to The Zero Day Initiative ZDI a File Parsing Vulnerability: Schneider Electric StruxureWare SCADA Expert ClearSCADA ServerMain.exe OPF File Parsing Vulnerability. Schneider Electric has prepared workarounds and helped develop security upgrades for a...

6.8CVSS6.6AI score0.01487EPSS
SaveExploits0References10
NVD
NVD
added 2014/12/06 3:59 p.m.16 views

CVE-2014-5429

DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...

5CVSS6.6AI score0.01358EPSS
SaveExploits0References1
Prion
Prion
added 2014/12/06 3:59 p.m.19 views

Code injection

DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...

5CVSS7.2AI score0.01358EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
added 2014/12/06 3:0 p.m.23 views

CVE-2014-5429

DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...

6.6AI score0.01358EPSS
SaveExploits0References1
CVE
CVE
added 2014/12/06 3:0 p.m.44 views

CVE-2014-5429

CVE-2014-5429 affects the DNP Master Driver (V3.02 and earlier) used by Elipse SCADA, Elipse E3 (V1.0–V4.6), and Elipse Power (V1.0–V4.6). The root cause is handling of malformed DNP packets, leading to resource exhaustion and a denial of service (CPU consumption). Affected products can become un...

5CVSS6.8AI score0.01358EPSS
SaveExploits0References1Affected Software1
ThreatPost
ThreatPost
added 2014/12/03 10:56 a.m.24 views

Elipse SCADA Denial of Service Patch

Brazilian process management software developer Elipse has patched a serious denial-of-service vulnerability in its web-based Elipse SCADA application. The software is used in a number of critical industries worldwide, including manufacturing, energy, water and wastewater plants. The vulnerabilit...

8.3AI score
SaveExploits0References11
ThreatPost
ThreatPost
added 2014/12/01 2:20 p.m.11 views

Researcher Releases Database of Known-Good ICS and SCADA Files

A prominent security researcher has put together a new database of hundreds of thousands of known-good files from ICS and SCADA software vendors in an effort to help users and other researchers identify legitimate files and home in on potentially malicious ones. The database, known as WhiteScope,...

7.6AI score
SaveExploits0References3
Check Point Advisories
Check Point Advisories
added 2014/11/27 12:0 a.m.25 views

Advantech WebAccess SCADA webeye.ocx ip_address Parameter Buffer Overflow (CVE-2014-8388)

A stack buffer overflow exists in Advantech's WebAccess SCADA software. The vulnerability is due to insufficient input validation of the ipaddress parameter contained in the webeye.ocx ActiveX control, a part of the WebAccess Client. A remote, unauthenticated attacker could exploit this...

7.2CVSS3.6AI score0.01051EPSS
SaveExploits1
ThreatPost
ThreatPost
added 2014/11/26 10:4 a.m.23 views

Siemens Patches WinCC Vulnerabilities Likely Being Exploited

Global industrial supplier Siemens has patched two critical vulnerabilities that it believes are likely being exploited. Organizations running products using the Siemens WinCC application are urged to apply available patches immediately; the company said it is working on updates for any remaining...

10CVSS2.4AI score0.05271EPSS
SaveExploits0References2
exploitpack
exploitpack
added 2014/11/26 12:0 a.m.55 views

Elipse E3 - HTTP Denial of Service

Elipse E3 - HTTP Denial of Service // Exploit Http DoS Request for SCADA ATTACK Elipse 3 // Mauro Risonho de Paula Assumpção aka firebits // [email protected] // 29-10-2013 11:42 // Vendor Homepage: http://www.elipse.com.br/port/index.aspx // Software Link:...

5CVSS0.2AI score0.02733EPSS
SaveExploits4
Exploit DB
Exploit DB
added 2014/11/26 12:0 a.m.40 views

Elipse E3 - HTTP Denial of Service

// Exploit Http DoS Request for SCADA ATTACK Elipse 3 // Mauro Risonho de Paula Assumpção aka firebits // [email protected] // 29-10-2013 11:42 // Vendor Homepage: http://www.elipse.com.br/port/index.aspx // Software Link: http://www.elipse.com.br/port/e3.aspx // Version: 3.x and prior //...

5CVSS5.2AI score0.02733EPSS
SaveExploits4
ThreatPost
ThreatPost
added 2014/11/21 11:0 a.m.17 views

Buffer Overflow Haunts Advantech WebAccess SCADA Product

The ICS-CERT is warning users about a stack buffer overflow in the Advantech WebAccess SCADA product that could lead to arbitrary code execution. Advantech WebAccess is a SCADA and human-machine interface product that’s accessible over the Web. It’s used in a variety of industries, including...

1.9AI score
SaveExploits0References2
zdt
zdt
added 2014/11/20 12:0 a.m.60 views

Advantech WebAccess 7.2 Stack-Based Buffer Overflow Vulnerability

Advantech WebAccess version 7.2 is vulnerable to a stack-based buffer overflow attack, which can be exploited by remote attackers to execute arbitrary code, by providing a malicious html file with specific parameters for an ActiveX component. Advantech WebAccess Stack-based Buffer Overflow 1...

7.2CVSS7.5AI score0.01051EPSS
SaveExploits1
OpenVAS
OpenVAS
added 2014/11/11 12:0 a.m.174 views

Nordex NC2 'username' Parameter Cross Site Scripting Vulnerability

Nordex NC2 is prone to a cross-site scripting XSS vulnerability. SPDX-FileCopyrightText: 2014 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

7.5CVSS5.8AI score0.01671EPSS
SaveExploits0References4
NVD
NVD
added 2014/11/05 11:55 a.m.15 views

CVE-2014-5408

Cross-site scripting XSS vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 NC2 SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter...

7.5CVSS5.8AI score0.01671EPSS
SaveExploits0References4
Rows per page