Lucene search
+L

3468 matches found

Metasploit
Metasploit
added 2016/09/11 7:15 a.m.66 views

Siemens Profinet Scanner

This module will use Layer2 packets, known as Profinet Discovery packets, to detect all Siemens and sometimes other devices on a network. It is perfectly SCADA-safe, as there will only be ONE single packet sent out. Devices will respond with their IP configuration and hostnames. Created by XiaK...

7.3AI score
SaveExploits0
n0where
n0where
added 2016/09/02 6:46 p.m.25 views

MODBUS Penetration Testing Framework: smod

MODBUS Penetration Testing Framework smod is a modular framework with every kind of diagnostic and offensive feature you could need in order to pentest modbus protocol. It is a full Modbus protocol implementation using Python and Scapy. This software could be run on Linux/OSX under python 2.7.x...

SaveExploits0References1
ICS
ICS
added 2016/08/02 12:0 a.m.76 views

Siemens SINEMA Server Privilege Escalation Vulnerability (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-215-02 Siemens SINEMA Server Privilege Escalation Vulnerability that was published August 2, 2016, on the NCCIC/ICS-CERT web site. --------- Begin Update A Part 1 of 2 -------- Security researcher rgod working...

7.8CVSS0.9AI score0.00475EPSS
SaveExploits0References21
ThreatPost
ThreatPost
added 2016/07/27 12:27 p.m.20 views

Attributing Advanced Attacks Remains Challenge For Researchers

Amid the connections being made between the Russian government and the attack on the Democratic National Committee DNC, researchers on Tuesday reminded us of the challenges security experts have in correctly attributing advanced attacks. In a wide-ranging Reddit AMA, members of Kaspersky Lab’s...

SaveExploits0References3
ThreatPost
ThreatPost
added 2016/07/21 7:0 a.m.23 views

IoT Insecurity: Top Connected Device Security Concerns

It’s a coin toss whether or not that Internet of Things device you depend on is secure. Those unacceptable 50/50 odds come from a survey by IOActive where technology professionals were asked about the security of connected devices from thermostats, security cameras to alarm systems. Those numbers...

6.4CVSS0.1AI score0.01728EPSS
SaveExploits0References4
NVD
NVD
added 2016/07/15 4:59 p.m.16 views

CVE-2016-5787

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

6.3CVSS6.1AI score0.00394EPSS
SaveExploits0References3
Prion
Prion
added 2016/07/15 4:59 p.m.19 views

Design/Logic Flaw

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

4.6CVSS6.7AI score0.00394EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2016/07/15 4:0 p.m.51 views

CVE-2016-5787

CVE-2016-5787 affects GE Digital Proficy HMI/SCADA CIMPLICITY, prior to version 8.2 SIM 27. The root cause is improper handling of service DACLs, allowing a local user to modify the CIMPLICITY service configuration via unspecified vectors, enabling privilege elevation by tampering with the servic...

6.3CVSS6AI score0.00394EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2016/07/15 4:0 p.m.23 views

CVE-2016-5787

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

6.1AI score0.00394EPSS
SaveExploits0References3
ThreatPost
ThreatPost
added 2016/07/15 2:9 p.m.14 views

Scan Reveals Hydropower Plants, Other Critical Infrastructure Exposed Online

An Internet scan of the IPv4 address space uncovered more than 100 critical facilities exposed to the public Internet, including hydropower plants in Germany and Italy, and a smart building in Israel hosting luxury apartments. The investigation, conducted by researchers at Internet Wache of Berli...

7.5AI score
SaveExploits0References1
CNVD
CNVD
added 2016/07/15 12:0 a.m.33 views

GE Proficy HMI SCADA CIMPLICITY Local Privilege Vulnerability

GE Proficy HMI SCADA CIMPLICITY is a client/server based HMI/SCADA solution. A security vulnerability exists in GE Proficy HMI SCADA CIMPLICITY that allows a local attacker to exploit the vulnerability to elevate privileges...

6.3CVSS6.6AI score0.00394EPSS
SaveExploits0References1
The Hacker News
The Hacker News
added 2016/07/13 12:12 a.m.231 views

State-Sponsored SCADA Malware targeting European Energy Companies

Security researchers have discovered a new campaign targeting energy companies in Western Europe with a sophisticated malware that almost goes to great lengths in order to remain undetected while targeting energy companies. Researchers from SentinelOne Labs discovered the malware, which has alrea...

7.2CVSS8.2AI score0.87042EPSS
SaveExploits61
ThreatPost
ThreatPost
added 2016/07/11 8:32 a.m.14 views

91 Percent of Public-Facing ICS Components Are Remotely Exploitable

We live in an increasingly connected world, but even in an age when DDoS attacks can take entire airlines offline, many critically sensitive industrial control systems ICS are still connected to the internet. A pair of reports released today by Kaspersky Lab reveal how dire the situation really i...

0.2AI score
SaveExploits0References14
seebug.org
seebug.org
added 2016/07/11 12:0 a.m.51 views

GE Proficy HMI/SCADA CIMPLICITY 8.2 local mention the right vulnerability

No description provided by source...

7.1AI score
SaveExploits0
ICS
ICS
added 2016/07/08 6:0 a.m.42 views

INDAS Web SCADA Path Traversal Vulnerability

OVERVIEW Independent researcher Ehab Hussein of IOActive has identified a path traversal vulnerability in the INDAS Web SCADA application. INDAS has produced new software to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following INDAS Web SCAD...

7.5CVSS7.8AI score0.0357EPSS
SaveExploits0References10
zdt
zdt
added 2016/07/07 12:0 a.m.50 views

GE Proficy HMI/SCADA CIMPLICITY 8.2 - Privilege Escalation

Exploit for windows platform in category local exploits / Exploit Title: GE Proficy HMI/SCADA CIMPLICITY 8.2 Local Privilege Escalation Exploit0 day Vulnerability Discovery and Exploit Author: Zhou Yu Email: Version: 8.2 Tested on: Windows 7 SP1 X32 CVE : None Vulnerability Description:...

6.8AI score
SaveExploits0
n0where
n0where
added 2016/06/15 3:14 a.m.31 views

ICS SCADA NSA Situational Awareness: Grassmarlin

ICS SCADA NSA Situational Awareness: Grassmarlin Provide IP network situational awareness of industrial control systems ICS and Supervisory Control and Data Acquisition SCADA networks to support network security. Passively map, and visually display, an ICS/SCADA network topology while safely...

0.4AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2016/06/15 12:0 a.m.22 views

Cogent DataHub < 6.4.3 OPC Client Reconnection Saturation Remote DoS

Binary data scadacogentdatahub643.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2016/06/15 12:0 a.m.20 views

Cogent DataHub < 6.4.5Beta OPC Connection Failure DoS

Binary data scadacogentdatahub645beta.nbin...

7.3AI score
SaveExploits0References1
seebug.org
seebug.org
added 2016/06/09 12:0 a.m.42 views

And drainage SCADA industrial control systems /DataSrvs/UCCGSrv. asmx/GetWaterMeterType Parameter model SQL injection vulnerability

No description provided by source...

7.1AI score
SaveExploits0
Rows per page
Query Builder