3467 matches found
CVE-2019-10985
Advantech WebAccess/SCADA — CVE-2019-10985 affects versions 8.3.5 and earlier. Root cause: path traversal due to insufficient validation of a user-supplied path before file operations, enabling an attacker to delete files (as Administrator). Connected sources indicate remote exploitation potentia...
Advantech WebAccess/SCADA
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: WebAccess/SCADA Vulnerabilities: Path Traversal, Stack-based Buffer Overflow, Heap-based Buffer Overflow, Out-of-bounds Read, Out-of-bounds Write, Untrusted Pointer Dereference...
CVE-2019-3954
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call...
CVE-2019-3954
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call...
Stack overflow
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call...
Advantech WebAccess/SCADA Buffer Overflow Vulnerability (CNVD-2019-18839)
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphical display and real-time data control, and provides remote control and management of automation equipment. A buffer overflow vulnerability exists ...
Advantech WebAccess/SCADA Buffer Overflow Vulnerability (CNVD-2019-18756)
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, Taiwan, China. The software supports dynamic graphical display and real-time data control, and provides remote control and management of automation equipment. A stack-based buffer overflow...
CVE-2019-3954
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call...
CVE-2019-3954
CVE-2019-3954 affects Advantech WebAccess/SCADA 8.4.0. The vulnerability is a stack-based buffer overflow in the product that can be triggered remotely by an unauthenticated attacker through a crafted IOCTL 81024 RPC call, allowing arbitrary code execution. Multiple sources (NVD, Red Hat advisory...
CVE-2019-3953
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call...
CVE-2019-3953
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call...
Stack overflow
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call...
CVE-2019-3953
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call...
CVE-2019-3953
CVE-2019-3953 affects Advantech WebAccess/SCADA 8.4.0. A stack-based buffer overflow exists when handling IOCTL 10012 RPC calls, allowing a remote, unauthenticated attacker to execute arbitrary code. The entry is corroborated by multiple sources (NVD and national/national vulnerability databases)...
Siemens SCALANCE X (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: SCALANCE X Switches Vulnerability: Storing Passwords in a Recoverable Format 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-19-162-04 Siemens SCALANCE X...
AVEVA Vijeo Citect and CitectSCADA
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Low skill level to exploit Vendor: AVEVA Equipment: Vijeo Citect and CitectSCADA Vulnerability: Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a locally authenticated user to obtain...
Rockwell Automation MicroLogix 1100/1400 and CompactLogix 5370 Controllers Open Redirection Vulnerability
The Rockwell Automation MicroLogix 1100/1400 or CompactLogix 5370 controller web server is affected by an open redirect vulnerability. An unauthenticated remote attacker can exploit this issue in conjunction with a social engineering attack to redirect the user to a malicious site that could run ...
SEL AcSELerator Architect 2.2.24 Denial Of Service
!/usr/bin/env python coding: utf8 SEL AcSELerator Architect 2.2.24 Remote CPU Exhaustion Denial of Service Vendor: Schweitzer Engineering Laboratories, Inc. Product web page: https://www.selinc.com Affected version: 2.2.24.0 ICD package version: 2.38.0 Summary: Substation communications networks...
Multiple Siemens products vulnerable to encryption issues
Siemens SIMATIC WinCC is an automated data acquisition and monitoring SCADA system, Siemens SIMATIC HMI Comfort Panels is a touch panel device, Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device for outdoor use, and Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel devic...
Vulnerabilities in Permissions and Access Control Issues for Multiple Siemens Products
Siemens SIMATIC WinCC is an automated data acquisition and monitoring SCADA system, Siemens SIMATIC HMI Comfort Panels is a touch panel device, Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device for outdoor use, and Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel devic...