Lucene search
+L

3547 matches found

CNVD
CNVD
added 2021/10/13 12:00 a.m.65 views

Advantech WebAccess Heap Buffer Overflow Vulnerability

Advantech WebAccess is Advantech's suite of HMI/SCADA software based on browser architecture. A heap buffer overflow vulnerability exists in Advantech WebAccess 9.02 and earlier versions. An attacker could exploit this vulnerability to remotely execute code...

9.8CVSS9.7AI score0.02346EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/10/13 12:00 a.m.58 views

Schneider Electric Interactive Graphical SCADA System访问控制错误漏洞(CNVD-2022-13073)

Schneider Electric Interactive Graphical SCADA System IGSS is an advanced SCADA system for monitoring and controlling industrial processes.Schneider Electric Interactive Graphical SCADA System is vulnerable to An access control error vulnerability can be exploited to delete arbitrary files in the...

9.1CVSS3.3AI score0.0085EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/10/12 5:13 p.m.8 views

CVE-2021-38431

An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users...

4.3CVSS5.9AI score0.00698EPSS
SaveExploits0References2
ICS
ICS
added 2021/10/12 12:00 a.m.52 views

Advantech WebAccess SCADA

1. EXECUTIVE SUMMARY CVSS v3 4.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WebAccess SCADA Vulnerability: Missing Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access project names and paths. 3...

4.3CVSS4.7AI score0.00698EPSS
SaveExploits0References5
ICS
ICS
added 2021/10/12 12:00 a.m.59 views

Advantech WebAccess

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WebAccess Vulnerabilities: Heap-based Buffer Overflow, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to...

9.8CVSS10AI score0.10367EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2021/10/12 12:00 a.m.13 views

Schneider Electric IGSS 访问控制错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is an advanced SCADA system for monitoring and controlling industrial processes.Schneider Electric Interactive Graphical SCADA System is vulnerable to An access control error vulnerability can be exploited to delete arbitrary files in the...

9.1CVSS5.8AI score0.0085EPSS
SaveExploits0References6
Packet Storm
Packet Storm
added 2021/10/11 12:00 a.m.357 views

Cypress Solutions CTM-200/CTM-ONE Hard-Coded Credentials Remote Root

!/usr/bin/env python3 Cypress Solutions CTM-200/CTM-ONE Hard-coded Credentials Remote Root Telnet/SSH Vendor: Cypress Solutions Inc. Product web page: https://www.cypress.bc.ca Affected version: CTM-ONE 1.3.6-latest CTM-ONE 1.3.1 CTM-ONE 1.1.9 CTM200 2.7.1.5659-latest CTM200 2.0.5.3356-184 Summar...

0.3AI score
SaveExploits0
Packet Storm
Packet Storm
added 2021/10/11 12:00 a.m.428 views

Cypress Solutions CTM-200 2.7.1 Root Remote OS Command Injection

Cypress Solutions CTM-200 2.7.1 Root Remote OS Command Injection Vendor: Cypress Solutions Inc. Product web page: https://www.cypress.bc.ca Affected version: 2.7.1.5659 2.0.5.3356-184 Summary: CTM-200 is the industrial cellular wireless gateway for fixed and mobile applications. The CTM-200 is a...

0.7AI score
SaveExploits0
OSV
OSV
added 2021/10/04 6:15 p.m.10 views

CVE-2021-41578

mySCADA myDESIGNER 8.20.0 and below allows Directory Traversal attacks when importing project files. If an attacker can trick a victim into importing a malicious mep file, then they gain the ability to write arbitrary files to OS locations where the user has permission. This would typically lead ...

7.8CVSS6AI score0.10779EPSS
SaveExploits0References1
OSV
OSV
added 2021/10/04 6:15 p.m.13 views

CVE-2021-41579

LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has...

7.8CVSS6AI score0.01268EPSS
SaveExploits1References1
ATTACKERKB
ATTACKERKB
added 2021/10/04 6:15 p.m.5 views

CVE-2021-41579

LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has...

7.8CVSS7.4AI score0.01268EPSS
SaveExploits1References2
CVE
CVE
added 2021/10/04 5:32 p.m.70 views

CVE-2021-41579

LCDS LAquis SCADA

7.8CVSS7.8AI score0.01268EPSS
SaveExploits1References1Affected Software1
CNNVD
CNNVD
added 2021/10/04 12:00 a.m.15 views

LCDS LAquis SCADA 路径遍历漏洞

LCDS LAquis SCADA is a SCADA Data Acquisition and Supervisory Control system from the Brazilian company LCDS. The system is mainly used for data acquisition and process control of equipment that has communication technology. LCDS LAquis SCADA has a security vulnerability that allows an attacker t...

7.8CVSS8AI score0.01268EPSS
SaveExploits1References2
Kitploit
Kitploit
added 2021/09/06 11:30 a.m.120 views

Nettacker - Automated Penetration Testing Framework

OWASP Nettacker project is created to automate information gathering, vulnerability scanning and eventually generating a report for networks, including services, bugs, vulnerabilities, misconfigurations, and other information. This software will utilize TCP SYN, ACK, ICMP, and many other protocol...

7.2AI score
SaveExploits0References5
CNVD
CNVD
added 2021/09/03 12:00 a.m.66 views

Advantech WebAccess Stack Buffer Overflow Vulnerability (CNVD-2021-80272)

Advantech WebAccess is Advantech's suite of HMI/SCADA software based on a browser architecture. A stack buffer overflow vulnerability exists in Advantech WebAccess 9.02 and earlier versions. The vulnerability stems from a lack of proper validation of the length of user-supplied data. An attacker...

9.8CVSS9.7AI score0.11569EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2021/08/31 12:00 a.m.14 views

The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System (IGSS) allows a intruder to perform arbitrary actions.

The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System IGSS is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow a intruder to execute arbitrary code...

7.8CVSS7.7AI score0.02489EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/08/23 12:00 a.m.15 views

The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System (IGSS) allows a intruder to perform arbitrary actions.

The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System IGSS is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow a intruder to execute arbitrary code...

7.8CVSS7.7AI score0.02477EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/08/18 12:00 a.m.14 views

The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020 and EcoStruxure Geo SCADA Expert 2019 lies in the insufficient protection of registration data, allowing unauthorized access by attackers to the protected information.

The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020 and EcoStruxure Geo SCADA Expert 2019 is related to insufficient protection of registration data. Exploiting this vulnerability can allow attackers to gain unauthorized access to protected information...

7.8CVSS7.2AI score0.0031EPSS
SaveExploits0References3Affected Software2
CNNVD
CNNVD
added 2021/08/17 12:00 a.m.13 views

xArrow SCADA 输入验证错误漏洞

xArrow SCADA is an installer for industrial control products from xArrow in China. An input validation error vulnerability exists in xArrow SCADA version 7.2 and prior versions, which arises from allowing unauthenticated registry entries to run with application-level privileges...

7.8CVSS7.4AI score0.0025EPSS
SaveExploits0References4
ICS
ICS
added 2021/08/17 12:00 a.m.113 views

xArrow SCADA

1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: xArrow Equipment: xArrow SCADA Vulnerabilities: Cross-site Scripting, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in remote code execution...

7.8CVSS7.2AI score0.00774EPSS
SaveExploits0References6
Rows per page