Advantech WebAccess
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WebAccess Vulnerabilities: Heap-based Buffer Overflow, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to...
Cypress Solutions CTM-200 2.7.1 Root Remote OS Command Injection
Cypress Solutions CTM-200 2.7.1 Root Remote OS Command Injection Vendor: Cypress Solutions Inc. Product web page: https://www.cypress.bc.ca Affected version: 2.7.1.5659 2.0.5.3356-184 Summary: CTM-200 is the industrial cellular wireless gateway for fixed and mobile applications. The CTM-200 is a...
Cypress Solutions CTM-200/CTM-ONE Hard-Coded Credentials Remote Root
!/usr/bin/env python3 Cypress Solutions CTM-200/CTM-ONE Hard-coded Credentials Remote Root Telnet/SSH Vendor: Cypress Solutions Inc. Product web page: https://www.cypress.bc.ca Affected version: CTM-ONE 1.3.6-latest CTM-ONE 1.3.1 CTM-ONE 1.1.9 CTM200 2.7.1.5659-latest CTM200 2.0.5.3356-184 Summar...
CVE-2021-41578
mySCADA myDESIGNER 8.20.0 and below allows Directory Traversal attacks when importing project files. If an attacker can trick a victim into importing a malicious mep file, then they gain the ability to write arbitrary files to OS locations where the user has permission. This would typically lead ...
CVE-2021-41579
LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has...
CVE-2021-41579
LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has...
CVE-2021-41579
LCDS LAquis SCADA
LCDS LAquis SCADA 路径遍历漏洞
LCDS LAquis SCADA is a SCADA Data Acquisition and Supervisory Control system from the Brazilian company LCDS. The system is mainly used for data acquisition and process control of equipment that has communication technology. LCDS LAquis SCADA has a security vulnerability that allows an attacker t...
Nettacker - Automated Penetration Testing Framework
OWASP Nettacker project is created to automate information gathering, vulnerability scanning and eventually generating a report for networks, including services, bugs, vulnerabilities, misconfigurations, and other information. This software will utilize TCP SYN, ACK, ICMP, and many other protocol...
Advantech WebAccess Stack Buffer Overflow Vulnerability (CNVD-2021-80272)
Advantech WebAccess is Advantech's suite of HMI/SCADA software based on a browser architecture. A stack buffer overflow vulnerability exists in Advantech WebAccess 9.02 and earlier versions. The vulnerability stems from a lack of proper validation of the length of user-supplied data. An attacker...
The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System (IGSS) allows a intruder to perform arbitrary actions.
The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System IGSS is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow a intruder to execute arbitrary code...
The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System (IGSS) allows a intruder to perform arbitrary actions.
The vulnerability of the executable file Def.exe in the interactive graphical SCADA system Interactive Graphical SCADA System IGSS is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow a intruder to execute arbitrary code...
The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020 and EcoStruxure Geo SCADA Expert 2019 lies in the insufficient protection of registration data, allowing unauthorized access by attackers to the protected information.
The vulnerability of SCADA systems such as EcoStruxure Geo SCADA Expert 2020 and EcoStruxure Geo SCADA Expert 2019 is related to insufficient protection of registration data. Exploiting this vulnerability can allow attackers to gain unauthorized access to protected information...
xArrow SCADA 输入验证错误漏洞
xArrow SCADA is an installer for industrial control products from xArrow in China. An input validation error vulnerability exists in xArrow SCADA version 7.2 and prior versions, which arises from allowing unauthenticated registry entries to run with application-level privileges...
xArrow SCADA 跨站脚本漏洞
xArrow SCADA is an installer for industrial control products from xArrow in China. A cross-site scripting vulnerability exists in xArrow SCADA. The vulnerability stems from a lack of proper validation of client-side data by the WEB application. An attacker can exploit this vulnerability to execut...
xArrow SCADA
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: xArrow Equipment: xArrow SCADA Vulnerabilities: Cross-site Scripting, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in remote code execution...
CVE-2021-32943
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1...
CVE-2021-22676
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting XSS, which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA...
CVE-2021-22676
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting XSS, which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA...
CVE-2021-32943
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1...