Lucene search
+L

3461 matches found

CVE
CVE
added 2022/02/09 10:4 p.m.102 views

CVE-2022-24312

Schneider Electric IGSS Data Server (IGSSdataServer.exe) v15.0.0.22020 and earlier is affected by CVE-2022-24312, a CWE-22 path traversal vulnerability that could allow modification of existing files or creation of new files in the Data Server context, potentially enabling remote code execution w...

9.8CVSS9.6AI score0.03463EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2022/02/09 10:4 p.m.26 views

CVE-2022-24312

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...

9.9AI score0.03463EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/02/09 10:4 p.m.26 views

CVE-2022-24310

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...

9.9AI score0.02227EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/09 10:4 p.m.110 views

CVE-2022-24310

CVE-2022-24310 affects Schneider Electric IGSS Data Server (v15.0.0.22020 and prior). Root cause: CWE-190 integer overflow/wraparound that can cause a heap-based buffer overflow, enabling denial of service and potentially remote code execution when processing multiple specially crafted messages. ...

9.8CVSS9.6AI score0.02227EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.6 views

Schneider Electric Interactive Graphical SCADA System 安全漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical SCADA System suffers from a buffer overflow...

9.8CVSS6.6AI score0.44559EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.8 views

Interactive Graphical SCADA System Data Server 缓冲区错误漏洞

The Schneider Electric Interactive Graphical Scada System is a Scada system for monitoring industrial processes from Schneider Electric, France. An out-of-bounds read vulnerability exists in the Schneider Electric Interactive Graphical Scada System, which can be exploited by an attacker to cause ...

7.5CVSS5.7AI score0.18178EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.9 views

EcoStruxure Geo SCADA Expert 信任管理问题漏洞

EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable supervisory control and data acquisition SCADA software A trust management issue vulnerability exists in EcoStruxure Geo SCADA Expert that stems from a possible man-in-the-middle attack when communication between a client and t...

5.9CVSS6AI score0.00544EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.7 views

EcoStruxure Geo SCADA Expert 代码问题漏洞

EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable surveillance and data acquisition SCADA software A code issue vulnerability exists in EcoStruxure Geo SCADA Expert that stems from a denial of service to the Geo SCADA server when an improper HTTP request is received...

7.5CVSS7.5AI score0.00999EPSS
SaveExploits0References2
CNVD
CNVD
added 2022/02/08 12:0 a.m.91 views

Siemens SIMATIC WinCC Information Disclosure Vulnerability

Siemens SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC, which can be exploited by an attacker to forcibly obtain credentials and take over the system using this command...

7.8CVSS7.2AI score0.0016EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/08 12:0 a.m.48 views

Siemens Spectrum Power 4 Cross-Site Scripting Vulnerability

Spectrum Power provides essential components for SCADA, communications and data modeling for control and monitoring systems. Siemens Spectrum Power 4 suffers from a cross-site scripting vulnerability that can be exploited by an attacker to conduct an attack if an unsuspecting user is tricked into...

6.1CVSS6AI score0.00562EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/01/24 12:0 a.m.54 views

Mitsubishi Electric MC Works64 Buffer Overflow Vulnerability

Mitsubishi Electric MC Works64 is a data acquisition and monitoring system SCADA from Mitsubishi Electric Japan. A security vulnerability exists in Mitsubishi Electric MC Works64 that stems from a coding error in the SQL query engine memory allocation code that makes it possible to execute a seri...

5.5CVSS6AI score0.01004EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/01/24 12:0 a.m.76 views

Unspecified Vulnerability in Mitsubishi Electric MC Works64

Mitsubishi Electric MC Works64 is a data acquisition and monitoring system SCADA from Mitsubishi Electric Japan. A security vulnerability exists in the Mitsubishi Electric MC Works64 that originates in ICONICS and the Mitsubishi Electric ICONICS product suite, where the FrameWorX server in the...

9.8CVSS9.5AI score0.02884EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/01/23 12:0 a.m.27 views

Mitsubishi Electric MC Works64 Cross-Site Scripting Vulnerability

Mitsubishi Electric MC Works64 is a data acquisition and monitoring system SCADA from Mitsubishi Electric Japan. Mitsubishi Electric MC Works64 suffers from a cross-site scripting vulnerability that stems from a lack of checksum filtering of user-supplied data and output. An attacker could exploi...

6.1CVSS6AI score0.01614EPSS
SaveExploits0References1
ICS
ICS
added 2022/01/20 7:0 a.m.67 views

Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric HMI SCADA (Update B)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: ICONICS and Mitsubishi Electric Equipment: ICONICS Product Suite, Mitsubishi Electric MC Works64 Vulnerabilities: Cross-site Scripting, Incomplete List of Disallowed Inputs, Plaintext Storage of a...

9.8CVSS6.6AI score0.02884EPSS
SaveExploits0References10
CNNVD
CNNVD
added 2022/01/06 12:0 a.m.9 views

Fernhill Software Fernhill Scada Server 资源管理错误漏洞

Fernhill Software Fernhill Scada Server is a free runtime Scada from Fernhill Software, UK. A resource management error vulnerability exists in Fernhill Software Fernhill SCADA Server that stems from the server's lack of effective filtering and processing of message formats. An attacker sending...

7.5CVSS7.3AI score0.01077EPSS
SaveExploits0References5
ICS
ICS
added 2022/01/06 12:0 a.m.51 views

Fernhill SCADA

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Fernhill Software, Ltd. Equipment: Fernhill SCADA Server Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service...

7.5CVSS7.8AI score0.01077EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2022/01/04 12:0 a.m.7 views

The vulnerability of SCADA systems with integrated web servers, related to the lack of file download restrictions, allows intruders to execute arbitrary code.

The vulnerability of SCADA systems with integrated web servers relates to the lack of restrictions on file downloads. Exploiting this vulnerability allows a malicious actor to execute arbitrary code remotely...

10CVSS8.2AI score0.35804EPSS
SaveExploits5References4Affected Software1
CNVD
CNVD
added 2021/12/23 12:0 a.m.13 views

Unspecified Vulnerability in mySCADA myPRO

mySCADA myPRO is an HMI/SCADA system designed primarily for the visualization and control of industrial processes. A security vulnerability exists in mySCADA myPRO that can be exploited by an attacker to crack a previously retrieved password hash...

7.5CVSS7.6AI score0.00651EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/12/23 12:0 a.m.12 views

mySCADA myPRO Authentication Bypass Vulnerability

mySCADA myPRO is an HMI/SCADA system designed primarily for the visualization and control of industrial processes. An authentication bypass vulnerability exists in mySCADA myPRO, which can be exploited by an attacker to access the application without any form of authentication or authorization...

9.8CVSS9.7AI score0.01549EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/12/23 12:0 a.m.23 views

mySCADA myPRO OS Command Injection Vulnerability (CNVD-2021-102828)

mySCADA myPRO is an HMI/SCADA system designed primarily for the visualization and control of industrial processes. An operating system command injection vulnerability exists in mySCADA myPRO, which can be exploited by an attacker to inject arbitrary operating system commands via specific paramete...

10CVSS9.9AI score0.01218EPSS
SaveExploits0References1
Rows per page
Query Builder