Lucene search
+L

141 matches found

NVD
NVD
•added 2022/04/12 5:15 p.m.•46 views

CVE-2022-21155

A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process FHSvrService.exe to exit...

7.5CVSS0.01121EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/12 12:00 a.m.•7 views

CVE-2022-21155: Uncontrolled Resource Consumption

A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process FHSvrService.exe to exit...

7.5CVSS7.2AI score0.01121EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/04/12 12:00 a.m.•3 views

PT-2022-14887

Name of the Vulnerable Software and Affected Versions Fernhill SCADA Server versions 3.77 and earlier Description A specially crafted packet sent to the server may cause an exception, leading to the server process FHSvrService.exe to exit. Recommendations For Fernhill SCADA Server versions 3.77 a...

7.5CVSS5.8AI score0.01121EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2022/02/09 11:15 p.m.•15 views

CVE-2022-24321

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA All Versions, EcoStruxure Geo SCADA Expert 2019 All Versions, EcoStruxure Geo...

7.5CVSS7.1AI score0.00999EPSS
SaveExploits0References2
OSV
OSV
•added 2022/02/09 11:15 p.m.•14 views

CVE-2022-24317

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS7.1AI score0.01206EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2022/01/06 12:00 a.m.•19 views

Fernhill Software Fernhill Scada Server 资源管理错误漏洞

Fernhill Software Fernhill Scada Server is a free runtime Scada from Fernhill Software, UK. A resource management error vulnerability exists in Fernhill Software Fernhill SCADA Server that stems from the server's lack of effective filtering and processing of message formats. An attacker sending...

7.5CVSS7.3AI score0.01121EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/04/21 12:00 a.m.•17 views

PT-2021-6930 · Elcomplus · Elcomplus Smartptt

Name of the Vulnerable Software and Affected Versions: Elcomplus SmartPTT affected versions not specified Description: The issue is related to authorization errors in the Elcomplus SmartPTT scada-server, allowing a low-authenticated user to access higher-level administration authorization. This c...

9CVSS8.3AI score0.00637EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2021/04/21 12:00 a.m.•1 views

PT-2021-6929

Name of the Vulnerable Software and Affected Versions Elcomplus SmartPTT SCADA Server affected versions not specified Description The issue is related to the disclosure of information. It allows a remote attacker to reveal protected information by requesting various files from the server without...

9.8CVSS0.01101EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/04/21 12:00 a.m.•3 views

PT-2021-6931

Name of the Vulnerable Software and Affected Versions Elcomplus SmartPTT SCADA Server affected versions not specified Description The issue is related to insufficient verification of the source of HTTP requests. This can allow a remote attacker to perform a CSRF attack using a specially crafted w...

8.8CVSS0.00368EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/04/21 12:00 a.m.•1 views

PT-2021-6932

Name of the Vulnerable Software and Affected Versions Elcomplus SmartPTT affected versions not specified Description The issue is related to the injection of JavaScript code into a specific parameter, which can be executed when accessing the dashboard or the main page. This can allow a remote...

9CVSS0.00648EPSS
SaveExploits0References9
Positive Technologies
Positive Technologies
•added 2021/04/21 12:00 a.m.•3 views

PT-2021-6927

Name of the Vulnerable Software and Affected Versions Elcomplus SmartPTT affected versions not specified Description The issue is related to the unlimited upload of dangerous file types in the update loading function of the scada-server. This could allow a remote attacker to execute arbitrary cod...

10CVSS0.01175EPSS
SaveExploits0References8
NVD
NVD
•added 2020/02/19 9:15 p.m.•32 views

CVE-2020-6970

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

9.8CVSS9.7AI score0.02579EPSS
SaveExploits0References1
Prion
Prion
•added 2020/02/19 9:15 p.m.•23 views

Heap overflow

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

7.5CVSS9.6AI score0.02579EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2020/02/19 8:19 p.m.•108 views

CVE-2020-6970

The CVE-2020-6970 issue affects Emerson OpenEnterprise SCADA Server: OpenEnterprise Server 2.83 (with Modbus or ROC Interfaces in use) and OpenEnterprise 3.1–3.3.3. It is a heap-based buffer overflow enabling a specially crafted script to execute code on the OpenEnterprise Server. Mitigation per ...

9.8CVSS9.5AI score0.02579EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/19 12:00 a.m.•6 views

CVE-2020-6970: Heap-based Buffer Overflow

A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 if Modbus or ROC Interfaces have been installed and are in use and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server...

9.8CVSS8.1AI score0.02579EPSS
SaveExploits0References3
ICS
ICS
•added 2020/02/18 12:00 a.m.•76 views

Emerson OpenEnterprise

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Emerson Equipment: OpenEnterprise SCADA Server Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code on an OpenEnterprise SCADA...

9.8CVSS9.7AI score0.02579EPSS
SaveExploits0References5
Zero Science Lab
Zero Science Lab
•added 2016/05/08 12:00 a.m.•93 views

Certec EDV atvise SCADA server 2.5.9 Privilege Escalation Vulnerability

Summary atvise scada is based on newest technologies and standards: The visualization in pure web technology as well as a consistent vertical object orientation based on OPC UA changes the world of process management systems. Description The application suffers from an unquoted search path issue...

6.2AI score
SaveExploits0
seebug.org
seebug.org
•added 2016/03/15 12:00 a.m.•21 views

Ecava IntegraXor SCADA Server权限访问漏洞

No description provided by source...

7.1AI score
SaveExploits0
NVD
NVD
•added 2015/04/03 10:59 a.m.•33 views

CVE-2015-0990

Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory...