22 matches found
EUVD-2022-29213
Malicious code in bioql PyPI...
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24310
CVE-2022-24310 affects Schneider Electric IGSS Data Server (v15.0.0.22020 and prior). Root cause: CWE-190 integer overflow/wraparound that can cause a heap-based buffer overflow, enabling denial of service and potentially remote code execution when processing multiple specially crafted messages. ...
PT-2022-16600
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A CWE-665: Improper Initialization issue exists, potentially causing information exposure when an attacker sends a specially crafted message...
CVE-2022-24317: Missing Authorization
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316: Improper Initialization
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24315: Out-of-bounds Read
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24314: Out-of-bounds Read
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24311: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...
CVE-2022-24313: Buffer Copy without Checking Size of Input
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...
CVE-2022-24312: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
CVE-2022-24310: Integer Overflow or Wraparound
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...
PT-2022-16601
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions prior to 15.0.0.22020 Description A Missing Authorization issue exists that could cause information exposure when an attacker sends a specific message. Recommendations For versions prior ...
PT-2022-1814
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is related to an out-of-bounds read, which could cause memory leaks and potentially result in denial of service. This can happen when an...
PT-2022-1815
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by inserting at the beginning of the file or create a new file in the context ...
PT-2022-2281
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by adding to the end of the file or create a new file in the context of the Da...
PT-2022-2280
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is caused by a stack-based buffer overflow due to a buffer copy without checking the size of the input. This could potentially lead to remote...