Lucene search
+L

22 matches found

EUVD
EUVD
•added 2025/10/03 8:07 p.m.•14 views

EUVD-2022-29213

Malicious code in bioql PyPI...

7.5CVSS7.6AI score0.19255EPSS
SaveExploits0References2
NVD
NVD
•added 2022/02/09 11:15 p.m.•30 views

CVE-2022-24317

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS0.01206EPSS
SaveExploits0References2
NVD
NVD
•added 2022/02/09 11:15 p.m.•29 views

CVE-2022-24315

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS0.19255EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2022/02/09 10:05 p.m.•43 views

CVE-2022-24317

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5AI score0.01206EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2022/02/09 10:05 p.m.•42 views

CVE-2022-24316

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5AI score0.01273EPSS
SaveExploits0References2
CVE
CVE
•added 2022/02/09 10:04 p.m.•125 views

CVE-2022-24310

CVE-2022-24310 affects Schneider Electric IGSS Data Server (v15.0.0.22020 and prior). Root cause: CWE-190 integer overflow/wraparound that can cause a heap-based buffer overflow, enabling denial of service and potentially remote code execution when processing multiple specially crafted messages. ...

9.8CVSS9.6AI score0.02227EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2022/02/09 12:00 a.m.•2 views

PT-2022-16600

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A CWE-665: Improper Initialization issue exists, potentially causing information exposure when an attacker sends a specially crafted message...

7.5CVSS0.01273EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•6 views

CVE-2022-24317: Missing Authorization

A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS6.5AI score0.01206EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•4 views

CVE-2022-24316: Improper Initialization

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS6.5AI score0.01273EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•4 views

CVE-2022-24315: Out-of-bounds Read

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS7.2AI score0.19255EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•4 views

CVE-2022-24314: Out-of-bounds Read

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS7.2AI score0.18178EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•9 views

CVE-2022-24311: Improper Limitation of a Pathname to a Restricted Directory

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...

9.8CVSS8.6AI score0.03505EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•4 views

CVE-2022-24313: Buffer Copy without Checking Size of Input

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...

9.8CVSS8.9AI score0.44559EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•5 views

CVE-2022-24312: Improper Limitation of a Pathname to a Restricted Directory

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...

9.8CVSS8.6AI score0.03463EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/09 12:00 a.m.•4 views

CVE-2022-24310: Integer Overflow or Wraparound

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Serv...

9.8CVSS8.7AI score0.02227EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/02/09 12:00 a.m.•3 views

PT-2022-16601

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions prior to 15.0.0.22020 Description A Missing Authorization issue exists that could cause information exposure when an attacker sends a specific message. Recommendations For versions prior ...

7.5CVSS0.01206EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2022/02/08 12:00 a.m.•1 views

PT-2022-1814

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is related to an out-of-bounds read, which could cause memory leaks and potentially result in denial of service. This can happen when an...

7.8CVSS0.18178EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2022/02/08 12:00 a.m.•1 views

PT-2022-1815

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by inserting at the beginning of the file or create a new file in the context ...

9.8CVSS0.03505EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2022/02/08 12:00 a.m.•1 views

PT-2022-2281

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description A vulnerability exists that could cause modification of an existing file by adding to the end of the file or create a new file in the context of the Da...

10CVSS0.03463EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2022/02/08 12:00 a.m.•1 views

PT-2022-2280

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is caused by a stack-based buffer overflow due to a buffer copy without checking the size of the input. This could potentially lead to remote...

10CVSS0.44559EPSS
SaveExploits0References5
Rows per page
Query Builder