400 matches found
CVE-2022-25417
Tenda AC9 V15.03.2.21cn was discovered to contain a stack overflow via the function saveparentcontrolinfo...
CVE-2022-38313
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo...
CVE-2022-37804
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter in the function saveParentControlInfo...
CVE-2022-25428
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function...
CVE-2022-25449
Tenda AC6 v15.03.05.09multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function...
CVE-2022-25433
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function...
CVE-2022-25429
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function...
CVE-2021-38278
Tenda AC10-1200 v15.03.06.23EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function...
CVE-2025-29359
Tenda RX3 USRX3V1.0brV16.03.13.11multiTDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted packet...
PT-2025-11180
Name of the Vulnerable Software and Affected Versions: Tenda RX3 US RX3V1.0br V16.03.13.11 multi TDE01 Description: The issue is related to a Buffer Overflow that can be triggered via the deviceId parameter at the "/goform/saveParentControlInfo" API endpoint. This allows attackers to cause a Deni...
CVE-2025-29363: Buffer Copy without Checking Size of Input
Tenda RX3 USRX3V1.0brV16.03.13.11multiTDE01 is vulnerable to buffer overflow via the schedStartTime and schedEndTime parameters at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted packet...
CVE-2025-29359: Buffer Copy without Checking Size of Input
Tenda RX3 USRX3V1.0brV16.03.13.11multiTDE01 is vulnerable to Buffer Overflow via the deviceId parameter at /goform/saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service DoS via a crafted packet...
The vulnerability of the formSetRebootTimer function (/goform/SetSysAutoRebbotCfg) in the Tenda AC8 router’s microprogramming system allows a intruder to compromise the confidentiality, integrity, and accessibility of the protected information.
The vulnerability of the compareparentcontroltime function /goform/saveParentControlInfo in the Tenda AC8 router’s microprogramming system is related to buffer overflow in the stack. Exploiting this vulnerability could allow an attacker to compromise the confidentiality, integrity, and...
CVE-2024-10123
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compareparentcontroltime of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be...
PT-2024-7382
Name of the Vulnerable Software and Affected Versions: Tenda AC8 version 16.03.34.06 Description: A critical issue has been found in the compare parentcontrol time function of the /goform/saveParentControlInfo file, which is affected by a stack-based buffer overflow. This can be exploited remotel...
Tenda AC18 ip/goform/saveParentControlInfo interface buffer overflow vulnerability
Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 suffers from a buffer overflow vulnerability that originates from the deviceId parameter of ip/goform/saveParentControlInfo failing to...
CVE-2024-33180
CVE-2024-33180 affects Tenda AC18 (firmware 15.03.3.10_EN). A stack-based buffer overflow originates from the deviceId parameter in ip/goform/saveParentControlInfo, enabling potential arbitrary code execution or denial of service. Documented impact is high for confidentiality, integrity, and avai...
CVE-2024-33180
Tenda AC18 V15.03.3.10EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo...
CVE-2024-33180: Out-of-bounds Write
Tenda AC18 V15.03.3.10EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo...
Tenda FH1205 saveParentControlInfo Method Stack Buffer Overflow Vulnerability
The Tenda FH1205 is a home wireless router from China's Tenda, geared toward the average home network environment, providing wireless connectivity. The Tenda FH1205 suffers from a stack buffer overflow vulnerability that originates from the deviceId parameter of the saveParentControlInfo method...