Lucene search
+L

6 matches found

NVD
NVD
•added 2023/04/11 9:15 p.m.•31 views

CVE-2023-28808

Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices...

9.8CVSS9.2AI score0.00825EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/04/11 12:00 a.m.•5 views

CVE-2023-28808: Improper Access Control

Some Hikvision Hybrid SAN/Cluster Storage products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices...

9.8CVSS5.9AI score0.00825EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2023/04/10 12:00 a.m.•4 views

PT-2023-2441

Name of the Vulnerable Software and Affected Versions Hikvision Hybrid SAN/Cluster Storage products affected versions not specified Description The issue is related to access control errors in the software, allowing a remote attacker to exploit the vulnerability and gain administrator privileges...

9.8CVSS0.00825EPSS
SaveExploits0References6
NVD
NVD
•added 2022/06/27 6:15 p.m.•41 views

CVE-2022-28171

The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device...

9.8CVSS0.51636EPSS
SaveExploits6References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/27 12:00 a.m.•3 views

CVE-2022-28171: Improper Neutralization of Special Elements used in an OS Command

The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to execute restricted commands by sending messages with malicious commands to the affected device...

9.8CVSS8.2AI score0.51636EPSS
SaveExploits6References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/06/27 12:00 a.m.•5 views

CVE-2022-28172: Improper Neutralization of Input During Web Page Generation

The web module in some Hikvision Hybrid SAN/Cluster Storage products have the following security vulnerability. Due to the insufficient input validation, attacker can exploit the vulnerability to XSS attack by sending messages with malicious commands to the affected device...

6.5CVSS6.3AI score0.00802EPSS
SaveExploits1References3
Rows per page
Query Builder