189 matches found
CVE-2026-37537
collin80/Open-SAE-J1939 thru commit 744024d4306bc387857dfce439558336806acb06 2023-03-08 contains an integer underflow leading to out-of-bounds write in Transport Protocol Data Transfer handling. At line 23: uint8t index = data0 - 1. When data0 sequence number from CAN frame is 0, index underflows...
PT-2026-36508
Name of the Vulnerable Software and Affected Versions Open-SAE-J1939 versions prior to commit b6caf884df46435e539b1ecbf92b6c29b345bdfe Description An integer underflow exists in the SAE J1939 Read Transport Protocol Data Transfer function. This allows attackers to write to arbitrary memory by usi...
CVE-2026-37534
Integer underflow vulnerability in Open-SAE-J1939 thru commit b6caf884df46435e539b1ecbf92b6c29b345bdfe 2025-11-30 in SAEJ1939ReadTransportProtocolDataTransfer,allows attackers to write to arbitrary memory via crafted sequence number from the CAN frame...
CVE-2020-10634
SAE IT-systems FW-50 Remote Telemetry Unit RTU. A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible...
EUVD-2021-24388
Malware in sbrugna...
EUVD-2019-18868
Malware in sbrugna...
EUVD-2019-18870
Malware in sbrugna...
EUVD-2022-28388
Malicious code in bioql PyPI...
EUVD-2021-27472
Malicious code in bioql PyPI...
EUVD-2024-29350
Malicious code in bioql PyPI...
PT-2025-5982 · Unknown · Siberiancms
Name of the Vulnerable Software and Affected Versions: SiberianCMS version 4.20.6 Description: A problem was found in SiberianCMS, affecting some unknown functionality of the file /app/sae/design/desktop/flat of the component HTTP GET Request Handler. This leads to cross-site scripting. The attac...
MAL-2024-9180 Malicious code in sae-viewer (npm)
--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware e232994dc60ca74f8ed71a17ce07b638d01a617b5ff03cdfed8b57b3c4e8ad8b Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...
Malicious code in sae-viewer (npm)
--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware e232994dc60ca74f8ed71a17ce07b638d01a617b5ff03cdfed8b57b3c4e8ad8b Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...
Updated hostapd & wpa_supplicant packages fix security vulnerability
The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...
Malicious Package
Overview sae-viewer is a malicious package. This package contains malicious code that collects sensitive information about the victim and sends it to the attacker's remote server. While this package might be attempting to impersonate a valid organization, there is no connection between that...
CVE-2024-46672 wifi: brcmfmac: cfg80211: Handle SSID based pmksa deletion
In the Linux kernel, the following vulnerability has been resolved: wifi: brcmfmac: cfg80211: Handle SSID based pmksa deletion wpasupplicant 2.11 sends since 1efdba5fdc2c "Handle PMKSA flush in the driver for SAE/OWE offload cases" SSID based PMKSA del commands. brcmfmac is not prepared and tries...
RHEL 8 : wpa_supplicant (Unpatched Vulnerability)
The remote Redhat Enterprise Linux 8 host has one or more packages installed that are affected by multiple vulnerabilities that have been acknowledged by the vendor but will not be patched. - wpasupplicant: SAE side channel attacks as a result of cache access patterns CVE-2022-23303 - The...
CVE-2023-52424
The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...
CVE-2023-52424
The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive th...
CVE-2023-52424
CVE-2023-52424 describes an SSID confusion vulnerability in IEEE 802.11 where the SSID is not always used to derive PMK/session keys and the 4‑way handshake may proceed without a protected SSID exchange. An adjacent attacker can lure victims to connect to an unintended/untrusted network using Hom...