2081 matches found
Cross site scripting
Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI...
CVE-2012-3040
CVE-2012-3040 affects Siemens SIMATIC S7-1200 PLCs (web server) 2.x–3.0.1. The root cause is improper input neutralization in the web application (CWE-79), allowing remote attackers to inject arbitrary web script or HTML via a crafted URI. Impact described as enabling attacker-controlled JavaScri...
CVE-2012-3040
Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI...
Siemens SIMATIC S7-1200 PLC Detection
Detection of Siemens SIMATIC S7-1200 PLC. This VT has been deprecated and replaced by the VT SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...
Siemens SIMATIC S7-1200 PLC 'web server' Component XSS Vulnerability (SSA-279823)
Siemens SIMATIC S7-1200 devices are prone to a cross-site scripting XSS vulnerability because they fail to properly sanitize user-supplied input. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective...
CVE-2012-3037
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...
Code injection
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...
CVE-2012-3037
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...
CVE-2012-3037
The CVE-2012-3037 vul nerability affects Siemens SIMATIC S7-1200 PLCs (2.x) where the private key of the SIMATIC CONTROLLER Certification Authority certificate is not protected in HTTPS storage. This allows remote attackers to forge a certificate and spoof the S7-1200 web server. Affected product...
Siemens SIMATIC S7-1200 SSL Private Key Reuse Spoofing Vulnerability (SSA-240718)
Siemens SIMATIC S7-1200 devices are prone to a security vulnerability that may allow attackers to spoof SSL certificates. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...
CVE-2012-3017
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...
CVE-2012-3016
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...
Code injection
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...
Code injection
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...
CVE-2012-3017
Summary: CVE-2012-3017 affects Siemens SIMATIC S7-400 PN CPU devices running firmware 5.x. The vulnerability allows remote attackers to trigger a denial of service (defect-mode transition and service outage) by sending malformed HTTP traffic or malformed IP packets. The publicly provided document...
CVE-2012-3016
The vulnerability CVE-2012-3016 affects Siemens SIMATIC S7-400 PN CPU devices running firmware 6 up to (but not including) 6.0.3. It allows remote attackers to cause a DoS by sending crafted ICMP packets, potentially forcing the PLC into defect mode with a manual reset needed to restore operation...
CVE-2012-3016
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...
CVE-2012-3017
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...
Siemens Simatic S7-300/400 CPU START/STOP Module
Exploit Title: Siemens Simatic S7 300/400 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-300 PLC CVE : None require 'msf/core' class Metasploit3 'Siemens Simatic S7-300/400 CPU START/STOP Module',...
Siemens Simatic S7-1200 CPU START/STOP Module
Exploit Title: Siemens Simatic S7 1200 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3 'Siemens Simatic S7-1200 CPU START/STOP Module', 'Description'...