Lucene search
K

7 matches found

Tenable Nessus
Tenable Nessus
added 2023/01/05 12:0 a.m.32 views

Siemens Multiple Denial of Service in Industrial Products (CVE-2021-44693)

A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants, SIMATIC S7-1200 CPU family incl. SIPLUS variants, SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMAT...

7.5CVSS5.3AI score0.00719EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2023/01/05 12:0 a.m.30 views

Siemens Multiple Denial of Service in Industrial Products (CVE-2021-40365)

A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants, SIMATIC S7-1200 CPU family incl. SIPLUS variants, SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMAT...

7.5CVSS7.2AI score0.00871EPSS
Exploits0References3
CNVD
CNVD
added 2022/12/14 12:0 a.m.31 views

Siemens Industrial Product Denial of Service Vulnerability (CNVD-2022-87982)

SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...

7.5CVSS5.2AI score0.00719EPSS
Exploits0References1
Tenable Nessus
Tenable Nessus
added 2022/03/21 12:0 a.m.66 views

Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37185)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...

7.5CVSS7.2AI score0.0206EPSS
Exploits0References3
NVD
NVD
added 2022/02/09 4:15 p.m.46 views

CVE-2021-37204

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...

7.5CVSS0.02181EPSS
Exploits0References1
CVE
CVE
added 2021/08/10 10:35 a.m.183 views

CVE-2020-28397

CVE-2020-28397 affects Siemens SIMATIC products due to an incorrect authorization check that could allow an attacker to read information about access-protected PLC variables via port 102/tcp when multiple attributes are read. Affected: SIMATIC Drive Controller family (all versions < V2.9.2); S...

5.3CVSS5AI score0.00752EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2021/05/28 4:10 p.m.272 views

CVE-2020-15782

CVE-2020-15782 covers Siemens SIMATIC S7-1200/1500 CPUs and related devices (including ET 200SP Open Controller, S7-PLCSIM Advanced, SINAMICS GH180, SINUMERIK MC/ONE, and S7-1500 Software Controller) with a memory protection bypass via a specific operation. A remote, unauthenticated attacker can ...

9.8CVSS9.5AI score0.05184EPSS
Exploits0References3Affected Software1
Rows per page