Lucene search
+L

25 matches found

RedhatCVE
RedhatCVE
•added 2025/02/06 12:12 a.m.•22 views

CVE-2022-47374

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS6.6AI score0.0072EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2024/01/04 12:00 a.m.•47 views

Siemens SIMATIC and SIPLUS Products Buffer Access with Incorrect Length Value (CVE-2022-47375)

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS6.9AI score0.00716EPSS
SaveExploits0References3
attackerkb
attackerkb
•added 2023/12/12 12:15 p.m.•13 views

CVE-2022-47374

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS7AI score0.0072EPSS
SaveExploits0References2
OSV
OSV
•added 2023/12/12 12:15 p.m.•17 views

CVE-2022-47375

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS6AI score0.00716EPSS
SaveExploits0References1
Prion
Prion
•added 2023/12/12 12:15 p.m.•36 views

Buffer overflow

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

5CVSS7.5AI score0.00716EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2023/12/12 11:25 a.m.•82 views

CVE-2022-47375

CVE-2022-47375 applies to Siemens SIMATIC/SIPLUS line, notably SIMATIC PC-Station Plus and S7-400 CPU variants, plus SINAMICS S120 (and SIPLUS) prior to SP3 HF15. The vulnerability is caused by improper handling of long file names in the web server, enabling a buffer overflow that can lead to a d...

7.5CVSS7.5AI score0.00716EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2023/12/12 11:25 a.m.•4 views

CVE-2022-47374

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS5.4AI score0.0072EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/12/12 12:00 a.m.•4 views

CVE-2022-47374: Uncontrolled Recursion

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS6.9AI score0.0072EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2023/12/12 12:00 a.m.•14 views

PT-2023-15289 · Siemens · Sinamics Sm120 +6

Name of the Vulnerable Software and Affected Versions: SIMATIC PC-Station Plus All versions SIMATIC S7-400 CPU 412-2 PN V7 All versions SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions SIMATIC S7-400 CPU...

7.5CVSS7.5AI score0.0072EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2023/12/12 12:00 a.m.•28 views

PT-2023-15290 · Siemens · Sinamics Sm120 +6

Name of the Vulnerable Software and Affected Versions: SIMATIC PC-Station Plus versions All SIMATIC S7-400 CPU 412-2 PN V7 versions All SIMATIC S7-400 CPU 414-3 PN/DP V7 versions All SIMATIC S7-400 CPU 414F-3 PN/DP V7 versions All SIMATIC S7-400 CPU 416-3 PN/DP V7 versions All SIMATIC S7-400 CPU...

7.5CVSS7.7AI score0.00716EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/12/12 12:00 a.m.•4 views

CVE-2022-47375: Buffer Access with Incorrect Length Value

A vulnerability has been identified in SIMATIC PC-Station Plus All versions, SIMATIC S7-400 CPU 412-2 PN V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 414F-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416-3 PN/DP V7 All versions, SIMATIC S7-400 CPU 416F-3 PN/D...

7.5CVSS7.2AI score0.00716EPSS
SaveExploits0References3
CNVD
CNVD
•added 2023/01/13 12:00 a.m.•81 views

Unspecified Vulnerability in Siemens S7-1500 CPU devices

SIMATIC drive controllers are designed for the automation of production machines, combining the functionality of the SIMATIC S7-1500 CPU and the SINAMICS S120 drive control.The SIMATIC S7-1500 CPU products are designed for discrete and continuous control in industrial environments such as global...

6.8CVSS6AI score0.00293EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/12/14 12:00 a.m.•125 views

Siemens Industrial Product Denial of Service Vulnerability (CNVD-2022-87984)

SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...

7.5CVSS5.2AI score0.00766EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/12/14 12:00 a.m.•142 views

Siemens Industrial Product Denial of Service Vulnerability

SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...

7.5CVSS7.5AI score0.00929EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/12/14 12:00 a.m.•198 views

Siemens Industrial Product Denial of Service Vulnerability (CNVD-2022-87982)

SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...

7.5CVSS5.2AI score0.00766EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/02/08 12:00 a.m.•116 views

Multiple Siemens Industrial Products Denial of Service Vulnerabilities

SIMATIC Drive Controller family products are machines designed for production automation, combining the functionality of the SIMATIC S7-1500 CPU and the SINAMICS S120 drive control.SIMATIC S7-1200 CPU family products are designed for discrete and continuous control in industrial environments such...

7.5CVSS7.5AI score0.0206EPSS
SaveExploits0References1
OSV
OSV
•added 2021/08/11 4:15 p.m.•15 views

CVE-2021-38547

Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the...

5.9CVSS5.8AI score0.01346EPSS
SaveExploits1References1
Prion
Prion
•added 2021/08/11 4:15 p.m.•26 views

Code injection

Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the...

4.3CVSS5.8AI score0.01346EPSS
SaveExploits1References1Affected Software2
attackerkb
attackerkb
•added 2021/08/11 4:15 p.m.•15 views

CVE-2021-38547

Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the...

5.9CVSS6.4AI score0.01346EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2021/08/11 3:24 p.m.•46 views

CVE-2021-38547

Logitech Z120 and S120 speakers through 2021-08-09 allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a "Glowworm" attack. The power indicator LED of the speakers is connected directly to the power line, as a result, the...

6AI score0.01346EPSS
SaveExploits1References1
Rows per page
Query Builder