Lucene search
+L

49 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•9 views

CVE-2021-25662: Improper Handling of Exceptional Conditions

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.7AI score0.0164EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•7 views

CVE-2021-25660: Access of Memory Location After End of Buffer

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.6AI score0.00969EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/05/12 12:00 a.m.•3 views

PT-2021-16737

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Outdoor Panels V15 versions 7" & 15" incl. SIPLUS variants through V15.1 Update 5 SIMATIC HMI Comfort Outdoor Panels V16 versions 7" & 15" incl. SIPLUS variants through V16 Update 3 SIMATIC HMI Comfort Panels V15 versions 4...

7.5CVSS0.0164EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•6 views

CVE-2021-25661: Access of Memory Location After End of Buffer

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.6AI score0.01148EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2021/05/11 12:00 a.m.•4 views

PT-2021-7833

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Outdoor Panels versions prior to V15.1 Update 6 SIMATIC HMI Comfort Outdoor Panels versions prior to V16 Update 4 SIMATIC HMI Comfort Panels versions prior to V15.1 Update 6 SIMATIC HMI Comfort Panels versions prior to V16...

7.8CVSS0.01792EPSS
SaveExploits0References7
CNVD
CNVD
•added 2020/07/15 12:00 a.m.•20 views

Information Disclosure Vulnerability in Multiple Siemens Products

SIMATIC HMI Panels are used for operator control, machine and plant monitoring.SIMATIC WinCC Runtime Advanced is a visual runtime platform, machine and plant monitoring.SIPLUS extreme products are designed to be operable under extreme conditions and are based on Imatic, LOGO! SITOP, SINAMICS,...

6.5CVSS6.7AI score0.00332EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2020/07/14 2:15 p.m.•10 views

CVE-2020-7592

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation incl. SIPLUS variants All versions, SIMATIC HMI Basic Panels 2nd Generation incl. SIPLUS variants All versions, SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions, SIMATIC HMI KTP700F Mobile Arctic All...

6.5CVSS6.4AI score0.00332EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2020/07/14 12:00 a.m.•3 views

PT-2020-19641

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Basic Panels 1st Generation incl. SIPLUS variants All versions SIMATIC HMI Basic Panels 2nd Generation incl. SIPLUS variants All versions SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions SIMATIC HMI KTP700F Mobile Arct...

6.5CVSS0.00332EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/07/14 12:00 a.m.•10 views

CVE-2020-7592: Cleartext Transmission of Sensitive Information

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation incl. SIPLUS variants All versions, SIMATIC HMI Basic Panels 2nd Generation incl. SIPLUS variants All versions, SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions, SIMATIC HMI KTP700F Mobile Arctic All...

6.5CVSS5.7AI score0.00332EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2019/05/14 12:00 a.m.•4 views

PT-2019-2108

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V15.1 Update 1 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15.1 Update 1 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900, and KTP900F versions prior to V15...

5.4CVSS0.00876EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/14 12:00 a.m.•8 views

CVE-2019-6577: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...

5.4CVSS5.7AI score0.00876EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/14 12:00 a.m.•8 views

CVE-2019-6576: Undefined Security Weakness

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...

7.5CVSS5.6AI score0.01749EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/05/14 12:00 a.m.•10 views

CVE-2019-6572: Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...

9.1CVSS5.7AI score0.02721EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2019/04/09 12:00 a.m.•18 views

PT-2019-2034 · Siemens · Simatic Hmi Comfort Outdoor Panels 7" & 15" +16

Name of the Vulnerable Software and Affected Versions: SIMATIC CP 443-1 OPC UA versions prior to the fixed version SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions prior to V2.7 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15.1 Upd 4 SIMATIC HMI Comfort Panels 4" - 22"...

7.8CVSS7.5AI score0.01646EPSS
SaveExploits0References3
OSV
OSV
•added 2018/12/13 4:29 p.m.•16 views

CVE-2018-13813

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15 Update 4, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15 Update 4, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V15 Update 4, SIMATIC WinCC Runtime...

8.1CVSS5.7AI score0.01681EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•7 views

CVE-2018-13812: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15 Update 4, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15 Update 4, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V15 Update 4, SIMATIC WinCC Runtime...

7.5CVSS5.8AI score0.03572EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2018/12/13 12:00 a.m.•4 views

PT-2018-12200

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V14 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V14 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V14 SIMATIC WinCC Runtime...

8.8CVSS0.01684EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2018/12/13 12:00 a.m.•4 views

PT-2018-12198

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V15 Update 4 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15 Update 4 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V15 Upda...

7.5CVSS0.03572EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•7 views

CVE-2018-13813: URL Redirection to Untrusted Site

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15 Update 4, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15 Update 4, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V15 Update 4, SIMATIC WinCC Runtime...

8.1CVSS5.6AI score0.01681EPSS
SaveExploits0References3
CNVD
CNVD
•added 2015/04/09 12:00 a.m.•20 views

Siemens SIMATIC and SIMATIC WinCC HMI Comfort Panels Denial of Service Vulnerability

Siemens SIMATIC WinCC is a complete Supervisory Control and Data Acquisition SCADA solution for industry, ranging from single-user systems to multi-user systems supporting redundant servers and remote Web client solutions. A security vulnerability in Siemens SIMATIC HMI Comfort Panels WinCC TIA...

4.3CVSS5.8AI score0.01736EPSS
SaveExploits0References1
Rows per page
Query Builder