1914 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49895)
drm/amd/display: vulnerability caused by adding a check to ensure the index 'i' is within bounds before accessing transfer function points in cmhelpertranslatecurvetodegammahwformat, preventing buffer overflow errors. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49858)
efistub/tpm: Use ACPI reclaim memory for event log to avoid corruption The TPM event log table is a Linux specific construct, where the data produced by the GetEventLog boot service is cached in memory, and passed on to the OS using an EFI configuration table. The use of EFILOADERDATA here result...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41089)
drm/nouveau/dispnv04: null pointer dereference in nv17tvgethdmodes. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504576; scriptversion"1.2";...
Siemens RUGGEDCOM Devices Inadequate Encryption Strength (CVE-2021-37209)
The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in- the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40931)
mptcp: ensure snduna is properly initialized on connect. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504689; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-49913)
drm/amd/display: missing null check for toppipetoprogram in commitplanesforstream. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504619;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56661)
tipc: NULL deref in cleanupbearer. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504583; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49924)
fbdev: pxafb:use after free in pxafbtask. In the pxafbprobe function, it calls the pxafbinitfbinfo function, after which &fbi-task is associated with pxafbtask. Moreover, within this pxafbinitfbinfo function, the pxafbblank function within the &pxafbops struct is capable of scheduling work. If we...
Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-33024)
The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49882)
ext4: In ext4exttrytomergeup, path1.pbh should be set to NULL after it has been released, otherwise it may be released twice. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-47669)
nilfs2: state management vulnerability in error path of log writing function. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504649;...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53239)
ALSA: 6fire: The current 6fire code tries to release the resources right after the call of usb6firechipabort. But at this moment, the card object might be still in use as we're calling sndcardfreewhenclosed and cause potential UAFs. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42224)
net: dsa: mv88e6xxx: wrong check on empty list. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504568; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49975)
uprobes: vma xoladdvma maps the uninitialized page allocated by createxolarea into userspace. On some architectures x86 this memory is readable even without VMREAD permission. Additionally setting VMEXEC produces the same page protection attributes pgprott as setting both VMEXEC and VMREAD...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53104)
media: uvcvideo: Skip parsing frames of type UVCVSUNDEFINED in uvcparseformat This can lead to out of bounds writes since frames of this type were not taken into account when calculating the size of the frames buffer in uvcparsestreaming. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46771)
can: bcm: Remove proc entry when dev is unregistered. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504624; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56648)
net: hsr: avoid potential out-of-bound access in fillframeinfo. By extending the check to cover packets with only 14 bytes, it prevents uninitialized values from causing undefined behavior or security issues. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50184)
virtiopmem: Check device status before requesting flush. If a pmem device is in a bad status, the driver side could wait for host ack forever in virtiopmemflush, causing the system to hang. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46755)
wifi: mwifiex: Do not return unused priv in mwifiexgetprivbyid. mwifiexgetprivbyid returns the priv pointer corresponding to the bssnum and bsstype, but without checking if the priv is actually currently in use. Unused priv pointers do not have a wiphy attached to them which can lead to NULL...
Siemens SCALANCE and RUGGEDCOM Devices Time-of-check Time-of-use (TOCTOU) Race Condition (CVE-2024-50234)
wifi: iwlegacy: vulnerability due to stale interrupts not being cleared before resuming the iwl4965 device from hibernation, causing a race condition between the resume process and restart work. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...