CVE-2023-39269: Allocation of Resources Without Limits or Throttling
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in Parasolid, Solid Edge, TeamCenter, SoftwareCenter, SIMATIC, SICAM and Ruggedcom products. The vulnerabilities potentially enable a malicious party to execute attacks that could result in the following categories of damage: Denial-of-Service DoS. Manipulation o...
PT-2023-4772 · Unknown · Ruggedcom Crossbow
Name of the Vulnerable Software and Affected Versions: RUGGEDCOM CROSSBOW versions prior to V5.4 Description: A vulnerability has been identified that allows authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges. The issue is related to the...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 lies in the lack of measures to neutralize special elements during the processing of URL parameters when connecting to the...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 stems from the lack of measures to neutralize special elements used in the operating system’s processing of the...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows a perpetrator to gain unauthorized access to protected information.
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 is related to the use of an unreliable cryptographic algorithm. Exploiting this vulnerability can allow an unauthorize...
Siemens SCALANCE and RUGGEDCOM Products Missing Authorization (CVE-2022-31765)
Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to perform cross-site scripting attacks.
The vulnerability of the web interface of microprogramming software for routing and switching platforms such as RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 arises from the lack of protection for the web page structure during the processing of the getelements parameter...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 lies in the lack of measures to neutralize special elements used in the operating system’s processing of the upgrade-app U...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 lies in the lack of measures to neutralize special elements used in the operating system’s command for handling the...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to perform cross-site scripting attacks.
The vulnerability of the web interface of microprogramming software for routing and switching platforms such as RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 stems from the lack of protective measures for the website structure. Exploiting this vulnerability allows a remot...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 stems from the lack of measures to neutralize special elements used in the operating system’s processing of the SCEP CA...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to perform cross-site scripting attacks.
The vulnerability of the web interface of microprogramming software for routing and switching platforms such as RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 stems from the lack of measures taken to protect the structure of the web page during the processing of parameter...
The vulnerability of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows attackers to enhance their privileges and execute arbitrary commands.
The vulnerability of the web interface of microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 lies in the lack of measures to neutralize special elements used in the operating system’s command when processing the...
CISA Releases Nine Industrial Control Systems Advisories
CISA released nine Industrial Control Systems ICS advisories on July 13, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-194-01 Siemens RUGGEDCOM ROX ICSA-23-194-02 Siemens SiPass Integrated ICSA-23-194-03...
Siemens RUGGEDCOM ROX Command Injection Vulnerability (CNVD-2023-60610)
RUGGEDCOM products offer a degree of robustness and reliability that sets the standard for communication networks deployed in harsh environments. A command injection vulnerability exists in the Siemens RUGGEDCOM ROX, which stems from a lack of server-side input validation, making the install-app...
Siemens RUGGEDCOM ROX Weak Password Vulnerability
RUGGEDCOM products offer a degree of robustness and reliability that sets the standard for communication networks deployed in harsh environments. A weak password vulnerability exists in the Siemens RUGGEDCOM ROX, which can be exploited by an attacker to read and modify any data passed to the...
Siemens RUGGEDCOM ROX Cross-Site Scripting Vulnerability
RUGGEDCOM products offer a degree of robustness and reliability that sets the standard for communication networks deployed in harsh environments. A cross-site scripting vulnerability exists in Siemens RUGGEDCOM ROX, which can be exploited by attackers to execute malicious javascript code by...
Siemens RUGGEDCOM ROX Cross-Site Request Forgery Vulnerability
RUGGEDCOM products offer a degree of robustness and reliability that sets the standard for communication networks deployed in harsh environments. A cross-site request forgery vulnerability exists in the Siemens RUGGEDCOM ROX, which can be exploited by an attacker to perform arbitrary actions on t...
Siemens RUGGEDCOM ROX Encryption Issue Vulnerability
RUGGEDCOM products offer a degree of robustness and reliability that sets the standard for communication networks deployed in harsh environments. A security vulnerability exists in the Siemens RUGGEDCOM ROX that stems from the affected device's web server supporting the insecure TLS 1.0 protocol...