Lucene search
+L

817 matches found

RedhatCVE
RedhatCVE
added 2025/05/22 10:48 p.m.21 views

CVE-2022-30264

The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol 4000/TCP, 5000/TCP for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the...

9.8CVSS7AI score0.0044EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:22 p.m.13 views

CVE-2022-30272

The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy Configurator for performing firmware updates. In case of the Easy Configurator, firmware updates are performed through access to the Web UI where file system, kerne...

7.2CVSS7.3AI score0.00432EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:49 p.m.12 views

CVE-2020-7801

The Synergy Systems & Solutions SSS HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposure of Sensitive Information to an Unauthorized Actor CWE-200 vulnerability. The affected product is vulnerable to information exposure over the SNMP protocol. This is a different issue than...

9.8CVSS6.2AI score0.02218EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:31 a.m.11 views

CVE-2019-14926

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with...

9.8CVSS7.3AI score0.02085EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:22 a.m.11 views

CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...

10CVSS7.6AI score0.02343EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:22 a.m.13 views

CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...

6.5CVSS6.7AI score0.0126EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:22 a.m.7 views

CVE-2019-14927

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames,...

7.5CVSS7AI score0.41847EPSS
SaveExploits3References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:22 a.m.10 views

CVE-2019-14931

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...

10CVSS8.4AI score0.5766EPSS
SaveExploits3References1
RedhatCVE
RedhatCVE
added 2025/05/22 9:18 a.m.11 views

CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...

5.4CVSS5.7AI score0.44149EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:36 a.m.11 views

CVE-2019-20046

The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...

9.8CVSS7AI score0.02218EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:40 a.m.15 views

CVE-2019-20045

The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...

9.8CVSS6.8AI score0.02218EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/03/25 12:38 p.m.9 views

CVE-2025-1445

A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...

8.7CVSS7.2AI score0.00309EPSS
SaveExploits0References1
CVE
CVE
added 2025/03/25 12:38 p.m.68 views

CVE-2025-1445

CVE-2025-1445 affects Hitachi Energy RTU500 series, specifically the IEC 61850 client/server stack on CMU devices configured with TLS. The issue is a potential availability problem if renegotiation of an active IEC 61850 TLS connection occurs in certain timing scenarios. Precondition: TLS is enab...

8.7CVSS7.2AI score0.00309EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/03/25 12:38 p.m.24 views

CVE-2025-1445

A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...

8.7CVSS0.00309EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2025/03/25 12:0 a.m.4 views

Hitachi Energy RTU500 代码问题漏洞

Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Ltd Hitachi, Japan. A code issue vulnerability exists in the Hitachi Energy RTU500 that stems from a specially crafted message sequence that could lead to a denial of service in the RTU500 CMU application...

5.9CVSS6.6AI score0.0032EPSS
SaveExploits0References3
NCSC
NCSC
added 2024/06/11 11:33 a.m.12 views

Vulnerabilities fixed in Schneider Electric Sage RTU systems

Schneider Electric has fixed vulnerabilities in Sage RTU devices. A malicious party could exploit the vulnerabilities to launch attacks that could result in the following categories of damage: - Denial-of-Service DoS - Manipulation of data - Bypassing authentication - Circumvention of security...

9.8CVSS7.9AI score0.01025EPSS
SaveExploits0References2
NVD
NVD
added 2024/04/30 7:15 a.m.22 views

CVE-2024-4225

Multiple security vulnerabilities has been discovered in web interface of NetGuardian DIN Remote Telemetry Unit RTU, by DPS Telecom. Attackers can exploit those security vulnerabilities to perform critical actions such as escalate user's privilege, steal user's credential, Cross Site Scripting XS...

7.6CVSS7.9AI score0.00251EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2024/04/30 6:47 a.m.11 views

CVE-2024-4225 NGDIN_ST v2.0D.0062 - Multiple Vulnerabilities

Multiple security vulnerabilities has been discovered in web interface of NetGuardian DIN Remote Telemetry Unit RTU, by DPS Telecom. Attackers can exploit those security vulnerabilities to perform critical actions such as escalate user's privilege, steal user's credential, Cross Site Scripting XS...

7.6CVSS7.1AI score0.00251EPSS
SaveExploits0References1
CVE
CVE
added 2024/04/30 6:47 a.m.50 views

CVE-2024-4225

Affected product: NetGuardian DIN RTU Web Interface. Vulnerabilities: Multiple issues enabling privilege escalation, credential theft, XSS and CSRF. Impact (as stated): High confidentiality and integrity impact, low availability. CVSS: 3.1 base score 7.6; attack vector adjacent; privileges requir...

7.6CVSS6.9AI score0.00251EPSS
SaveExploits0References1
OSV
OSV
added 2024/03/05 12:15 p.m.6 views

CVE-2023-45591

A CWE-122 “Heap-based Buffer Overflow” vulnerability in the “loggergeneric” function of the “Axrtu” binary allows a remote authenticated attacker to trigger a memory corruption in the context of the binary. This may result in a Denial-of-Service DoS condition, possibly in the execution of arbitra...

8.8CVSS6.1AI score0.00728EPSS
SaveExploits0References1