Lucene search
+L

34 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.9 views

EUVD-2013-2746

Malware in sbrugna...

7.8CVSS7.6AI score0.03855EPSS
SaveExploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.14 views

EUVD-2013-2745

Malware in sbrugna...

7.8CVSS7.6AI score0.03855EPSS
SaveExploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.7 views

EUVD-2012-4620

Malware in sbrugna...

7.1CVSS7.4AI score0.02764EPSS
SaveExploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2013-2744

Malware in sbrugna...

7.8CVSS7.6AI score0.03855EPSS
SaveExploits0References2
Prion
Prion
added 2020/05/20 3:15 a.m.23 views

Race condition

Products that use EDS Subsystem: Version 28.0.1 and prior FactoryTalk Linx software Previously called RSLinx Enterprise: Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and...

4.8CVSS8.2AI score0.01263EPSS
SaveExploits0References1Affected Software5
Prion
Prion
added 2020/05/19 10:15 p.m.26 views

Memory corruption

Products that use EDS Subsystem: Version 28.0.1 and prior FactoryTalk Linx software Previously called RSLinx Enterprise: Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and...

4.3CVSS6.3AI score0.02499EPSS
SaveExploits1References1Affected Software5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.21 views

Rockwellautomation Rslinx Out-of-bounds Read

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sendin...

7.8CVSS1.5AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.25 views

Rockwellautomation Rslinx Integer Overflow or Wraparound

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a...

7.8CVSS1.7AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.21 views

Rockwellautomation Rslinx Out-of-bounds Read

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram...

7.8CVSS1.3AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.18 views

Rockwell Automation RSLinx Enterprise Irregular UDP Packet Size DOS

Binary data 720180.prm...

10CVSS7.3AI score0.07788EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.10 views

Rockwell Software RSLinx Enterprise - MobileView Communications Adapter

Binary data 754805.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.16 views

Rockwell Automation RSLinx Enterprise Zero Byte UDP Packet DOS

Binary data 720179.prm...

7.1CVSS7AI score0.02764EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.14 views

Rockwell Software RSLinx Enterprise - Desktop Communications Adapter

Binary data 754803.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.10 views

Rockwell Software RSLinx Enterprise - RAC6182 Communications Adapter

Binary data 754804.prm...

7.3AI score
SaveExploits0
Prion
Prion
added 2019/03/26 6:29 p.m.24 views

Design/Logic Flaw

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sendin...

7.8CVSS6.7AI score0.03855EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2019/03/26 6:29 p.m.27 views

CVE-2013-2805

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sendin...

7.8CVSS7.3AI score0.03855EPSS
SaveExploits0References1
Prion
Prion
added 2019/03/26 5:29 p.m.19 views

Design/Logic Flaw

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a...

7.8CVSS7.3AI score0.03855EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2019/03/26 5:29 p.m.31 views

CVE-2013-2806

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a...

7.8CVSS7.8AI score0.03855EPSS
SaveExploits0References1
Prion
Prion
added 2019/03/26 5:29 p.m.20 views

Out-of-bounds

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram...

7.8CVSS7AI score0.03855EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2019/03/26 5:29 p.m.27 views

CVE-2013-2807

Rockwell Automation RSLinx Enterprise Software LogReceiver.exe CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram...

7.8CVSS7.6AI score0.03855EPSS
SaveExploits0References1
Rows per page
Query Builder