AVTECH Room Alert 3E Exposure of Resource to Wrong Sphere (CVE-2019-13379)

On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in. This plugin only works...

9CVSS7.3AI score0.02995EPSS
Exploits1References4
RedhatCVE
RedhatCVE
added 2025/05/22 10:6 a.m.7 views

CVE-2019-13379

On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults=RA reset and using the default credentials to get in...

9CVSS7.4AI score0.02995EPSS
Exploits1References1
CNVD
CNVD
added 2019/07/09 12:0 a.m.1 views

AVTECH Software Room Alert 3E Elevation of Privilege Vulnerability

AVTECH Software Room Alert 3E is a device for monitoring the IT infrastructure environment from AVTECH Software, USA. The product is mainly used to monitor temperature, humidity, power, electricity and smoke in computer rooms or small data centers. A security vulnerability exists in AVTECH Softwa...

9CVSS6.8AI score0.02995EPSS
Exploits1References1
OSV
OSV
added 2019/07/07 4:15 p.m.2 views

CVE-2019-13379

On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in...

8.8CVSS7.3AI score0.02995EPSS
Exploits1References3
NVD
NVD
added 2019/07/07 4:15 p.m.21 views

CVE-2019-13379

On AVTECH Room Alert 3E devices before 2.2.5, an attacker with access to the device's web interface may escalate privileges from an unauthenticated user to administrator by performing a cmd.cgi?action=ResetDefaults&src=RA reset and using the default credentials to get in...

9CVSS8.9AI score0.02995EPSS
Exploits1References3
CVE
CVE
added 2019/07/07 3:44 p.m.47 views

CVE-2019-13379

AVTECH Room Alert 3E devices with firmware versions prior to 2.2.5 are vulnerable to privilege escalation. An attacker who can access the device’s web interface can escalate from an unauthenticated user to administrator by sending cmd.cgi?action=ResetDefaults&src=RA reset and then using default c...

9CVSS8.8AI score0.02995EPSS
Exploits1References3Affected Software1