Lucene search
+L

345 matches found

Cvelist
Cvelist
added 2022/03/23 9:9 p.m.38 views

CVE-2022-27254

The remote keyless system on Honda Civic 2018 vehicles sends the same RF signal for each door-open request, which allows for a replay attack, a related issue to CVE-2019-20626...

5.8AI score0.01083EPSS
SaveExploits2References6
CVE
CVE
added 2022/03/23 9:9 p.m.232 views

CVE-2022-27254

The CVE-2022-27254 issue concerns Honda Civic family models (notably 2016–2020 per PT-2022-18332; 2018 Civic noted in the CVE) where the remote keyless system transmits the same RF signal for door open (and related actions), enabling a replay attack. Red Hat RH entries link this to CVE-2019-20626...

5.3CVSS6AI score0.01083EPSS
SaveExploits2References6Affected Software1
GithubExploit
GithubExploit
added 2022/03/23 3:3 p.m.728 views

Exploit for Authentication Bypass by Capture-replay in Honda Civic_2018_Firmware

CVE-2022-27254 PoC for vulnerability in Honda's Remote Keyless...

5.3CVSS7.8AI score0.01083EPSS
SaveExploits2
CNNVD
CNNVD
added 2022/03/23 12:0 a.m.12 views

Honda Civic 安全漏洞

Honda Civic is an automobile from Honda Japan. The Honda Civic 2018 model year has a security vulnerability in the remote keyless system that stems from the remote keyless system sending the same RF signal for every door open request, which allows replay attacks, related to CVE-2019-20626...

5.3CVSS6.2AI score0.01083EPSS
SaveExploits2References7
NVD
NVD
added 2022/03/10 5:47 p.m.38 views

CVE-2022-26131

Power Line Communications PLC4TRUCKS J2497 trailer receivers are susceptible to remote RF induced signals...

9.8CVSS0.01321EPSS
SaveExploits0References1
Prion
Prion
added 2022/03/10 5:47 p.m.11 views

Design/Logic Flaw

Power Line Communications PLC4TRUCKS J2497 trailer receivers are susceptible to remote RF induced signals...

7.5CVSS9.4AI score0.01321EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/03/07 3:28 p.m.117 views

CVE-2022-26131

CVE-2022-26131 affects Power Line Communications PLC4TRUCKS J2497 (PLC) trailer receivers. Technical details in connected docs show Improper Protection against Electromagnetic Fault Injection (CWE-1319) with a CVSSv3 base score of 9.3, and related Missing Authentication for Critical Function (CWE...

9.8CVSS9.5AI score0.01321EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/03/07 3:28 p.m.49 views

CVE-2022-26131 ICSA-22-063-01 Improper Protection against Electromagnetic Fault Injection in Trailer Power Line Communications (PLC) J2497

Power Line Communications PLC4TRUCKS J2497 trailer receivers are susceptible to remote RF induced signals...

9.3CVSS9.6AI score0.01321EPSS
SaveExploits0References1
ICS
ICS
added 2022/03/04 12:0 a.m.74 views

Trailer Power Line Communications (PLC) J2497

1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable remotely/low attack complexity Equipment: Power Line Communications PLC: J2497 a.k.a. PLC4TRUCKS Vulnerabilities: Missing Authentication for Critical Function, Improper Protection against Electromagnetic Fault Injection 2. RISK EVALUATION...

9.1CVSS9.8AI score0.01191EPSS
SaveExploits0References4
OSV
OSV
added 2021/12/15 7:15 a.m.6 views

CVE-2021-40171

The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...

5.3CVSS5.8AI score0.00924EPSS
SaveExploits0References2
NVD
NVD
added 2021/12/15 7:15 a.m.26 views

CVE-2021-40170

An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...

6.8CVSS0.00883EPSS
SaveExploits1References2
NVD
NVD
added 2021/12/15 7:15 a.m.15 views

CVE-2021-40171

The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...

5.3CVSS0.00924EPSS
SaveExploits0References2
Prion
Prion
added 2021/12/15 7:15 a.m.21 views

Authentication flaw

An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...

5.8CVSS6.6AI score0.00883EPSS
SaveExploits1References2Affected Software1
Prion
Prion
added 2021/12/15 7:15 a.m.17 views

Information disclosure

The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...

5CVSS5.3AI score0.00924EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2021/12/15 6:47 a.m.55 views

CVE-2021-40170

The CVE-2021-40170 entry describes an RF replay attack in the SecuritasHome Startpaket (HPGW-G 0.0.2.23F BG_U-ITR-F1-BD_BL.A30.20181117). The vulnerability allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals, including disarming an armed system. A...

6.8CVSS6.5AI score0.00883EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
added 2021/12/15 6:47 a.m.39 views

CVE-2021-40170

An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...

6.8AI score0.00883EPSS
SaveExploits1References2
CVE
CVE
added 2021/12/15 6:45 a.m.57 views

CVE-2021-40171

The CVE-2021-40171 entry concerns the SecuritasHome Startpaket (HPGW-G 0.0.2.23F BG_U-ITR-F1-BD_BL.A30.20181117). Reported vulnerability: absence of notifications for ongoing RF jamming attacks, which can allow an attacker to block legitimate traffic without alerting the system owner. Public sour...

5.3CVSS5.2AI score0.00924EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2021/12/15 6:45 a.m.24 views

CVE-2021-40171

The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...

5.5AI score0.00924EPSS
SaveExploits0References2
NVD
NVD
added 2021/12/01 4:15 p.m.36 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS0.00477EPSS
SaveExploits0References2
CVE
CVE
added 2021/12/01 3:38 p.m.51 views

CVE-2020-10627

CVE-2020-10627 affects Insulet Omnipod Insulin Management System models with product IDs 19191 and 40160. The vulnerability stems from a wireless RF communication protocol between the insulin pump and the manufacturer’s Personal Diabetes Manager that does not properly implement authentication or ...

8.1CVSS8AI score0.00477EPSS
SaveExploits0References2Affected Software1
Rows per page
Query Builder