Lucene search
K

8 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-4255

Malware in sbrugna...

6.5CVSS6.9AI score0.00036EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2017-4251

Malware in sbrugna...

8.8CVSS8.8AI score0.0038EPSS
Exploits0References3
ThreatPost
ThreatPost
added 2021/09/02 11:3 a.m.15 views

Comcast RF Attack Leveraged Remotes for Surveillance

More details about a now-patched vulnerability in Comcast’s XR11 voice remotes have emerged, which would have made it easy for a threat actor to intercept radio frequency RF communications between the remote and the set-top box, effectively turning the remote into a surveillance device. The XR11...

7.3AI score
Exploits0References7
NVD
NVD
added 2018/04/25 1:29 p.m.13 views

CVE-2017-12712

The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3...

8.8CVSS8.9AI score0.0038EPSS
Exploits0References2
Prion
Prion
added 2018/04/25 1:29 p.m.8 views

Authentication flaw

The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3...

8.3CVSS8.7AI score0.0038EPSS
Exploits0References2Affected Software7
CVE
CVE
added 2018/04/25 1:0 p.m.51 views

CVE-2017-12716

CVE-2017-12716 affects Abbott/St. Jude pacemakers (Accent/Anthem family) with RF wireless interfaces. The root cause is Missing Encryption of Sensitive Data and related Improper Authentication issues in the device firmware, allowing a nearby attacker to issue commands via RF and potentially acces...

6.5CVSS6.4AI score0.00036EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2018/04/25 1:0 p.m.67 views

CVE-2017-12712

CVE-2017-12712 affects Abbott Laboratories pacemakers (Accent/Anthem, Accent MRI, Assurity/Allure, Assurity MRI) and related ICD/CRT-D devices. Root cause: Improper Authentication (CWE-287) in the pacemaker authentication algorithm using an authentication key and timestamp, allowing a nearby atta...

8.8CVSS8.7AI score0.0038EPSS
Exploits0References2Affected Software1
ThreatPost
ThreatPost
added 2017/08/31 1:26 p.m.27 views

FDA Recalls 465K Pacemakers Tied to MedSec Research

The United States Federal Drug Administration is recalling 465,000 pacemakers that attackers can gain unauthorized access to issue commands, change settings and maliciously disrupt. Affected are four models manufactured by Abbott Laboratories. According to the FDA, the recalls of affected...

8.3CVSS0.4AI score0.0038EPSS
Exploits0References4
Rows per page