5145 matches found
JVN#65171386: Multiple vulnerabilities in ID Link Manager and FUJITSU Software TIME CREATOR
ID Link Manager and FUJITSU Software TIME CREATOR provided by Fsas Technologies Inc. contain multiple vulnerabilities listed below. Path Traversal CWE-36 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N Base Score 8.6 CVE-2024-33620 Missing Authentication CWE-306...
CVE-2024-38467
Shenzhen Guoxin Synthesis image system before 8.3.0 allows unauthorized user information retrieval via the queryUser API...
CVE-2024-38467
Shenzhen Guoxin Synthesis image system before 8.3.0 allows unauthorized user information retrieval via the queryUser API...
CVE-2024-38467
The CVE-2024-38467 vulnerability affects Shenzhen Guoxin Synthesis Image System prior to version 8.3.0. The issue permits unauthorized retrieval of user information via the queryUser API, with CVSS v3.1 base score 7.5 (HIGH) and network access, no privileges or user interaction required. Remediat...
CVE-2024-27154
Passwords are stored in clear-text logs. An attacker can retrieve passwords. As for the affected products/models/versions, see the reference URL...
CVE-2024-27154 Passwords are stored in clear-text logs.
Passwords are stored in clear-text logs. An attacker can retrieve passwords. As for the affected products/models/versions, see the reference URL...
CVE-2024-27154
CVE-2024-27154 affects Toshiba multi-function printers (notably Toshiba e-STUDIO MFPs). The issue is that passwords are stored in clear-text logs, enabling an attacker with log access to retrieve passwords. Exploitation status is not documented in the provided sources. Impact is limited to disclo...
CVE-2024-27141 Pre-authenticated Time-Based Blind XXE injection
Toshiba printers use XML communication for the API endpoint provided by the printer. For the endpoint, XML parsing library is used and it is vulnerable to a time-based blind XML External Entity XXE vulnerability. An attacker can DoS the printers by sending a HTTP request without authentication. A...
CVE-2024-27141 Pre-authenticated Time-Based Blind XXE injection
Toshiba printers use XML communication for the API endpoint provided by the printer. For the endpoint, XML parsing library is used and it is vulnerable to a time-based blind XML External Entity XXE vulnerability. An attacker can DoS the printers by sending a HTTP request without authentication. A...
CVE-2024-38280
CVE-2024-38280 affects Motorola Solutions Vigilant Fixed LPR Coms Box (BCAV1F2-C600). The vulnerability is due to cleartext storage of sensitive data on disk, enabling an unauthorized physical attacker to retrieve credentials by extracting the device’s hard drive. Public sources confirm mitigatio...
CVE-2024-34112 ColdFusion CFDOCUMENT file retrieval / access control bypass
ColdFusion versions 2023u7, 2021u13 and earlier are affected by an Improper Access Control vulnerability that could result in arbitrary file system read. An attacker could exploit this vulnerability to gain unauthorized access to sensitive files or data. Exploitation of this issue does not requir...
DR Restore - Internal error occurred: Could not retrieve artifacts for prefix
Challenge A Veeam Kasten for Kubernetes DR Restore fails with the following error: Internal error occurred: "message":"Could not retrieve artifacts for prefix...
CVE-2024-33606
An attacker could retrieve sensitive files medical images as well as plant new medical images or overwrite existing medical images on a MicroDicom DICOM Viewer system. User interaction is required to exploit this vulnerability...
PT-2024-25372 · Unknown · Microdicom Dicom Viewer
Name of the Vulnerable Software and Affected Versions: MicroDicom DICOM Viewer affected versions not specified Description: The issue allows an attacker to retrieve sensitive files, such as medical images, and also enables them to add new medical images or overwrite existing ones on the system...
CVE-2024-3700
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer...
CVE-2024-1228
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 from that version...
CVE-2024-1228 Hardcoded password in Eurosoft Przychodnia
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 from that version...
CVE-2024-1228
CVE-2024-1228 involves a hard-coded password to the patients’ database in Eurosoft Przychodnia software. Connected Red Hat and related records confirm the vulnerability affects Eurosoft Przychodnia installations prior to version 20240417.001, where it is fixed in that release. The credential weak...
RHEL 8 : idm:DL1 (RHSA-2024:3759)
The remote Redhat Enterprise Linux 8 host has packages installed that are affected by multiple vulnerabilities as referenced in the RHSA-2024:3759 advisory. Red Hat Identity Management IdM is a centralized authentication, identity management, and authorization solution for both traditional and...
PYSEC-2024-184
A local file inclusion vulnerability exists in the JSON component of gradio-app/gradio version 4.25. The vulnerability arises from improper input validation in the postprocess function within gradio/components/jsoncomponent.py, where a user-controlled string is parsed as JSON. If the parsed JSON...