2463 matches found
CVE-2022-45482
CVE-2022-45482 concerns the Lazy Mouse server, where the vulnerability is caused by weak password requirements and lack of rate limiting. This allows remote, unauthenticated attackers to brute force the PIN and potentially execute arbitrary commands. The core data sources describe the affected co...
CVE-2022-3270
The CVE-2022-3270 issue affects Festo automation controllers that use the FGMC protocol. A remote, unauthenticated attacker can invoke functions exposed by an undocumented protocol, potentially rebooting devices and causing a complete loss of confidentiality, integrity, and availability (DoS). Re...
Mitsubishi Electric MELSEC iQ-R Series
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-R Series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote unauthenticated attacker...
CVE-2022-29826
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control SettingGX Works3 related software versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-29827
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally...
CVE-2022-29830
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control SettingGX Works3 related software versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a...
Hardcoded credentials
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules...
Information disclosure
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
Design/Logic Flaw
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally...
Design/Logic Flaw
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control SettingGX Works3 related software versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-29833
CVE-2022-29833 affects Mitsubishi Electric GX Works3, versions 1.015R and later. The issue is labeled Insufficiently Protected Credentials, enabling a remote unauthenticated attacker to disclose sensitive information, potentially allowing access to MELSEC safety CPU modules. Connected advisories ...
CVE-2022-29831
CVE-2022-29831 affects Mitsubishi Electric GX Works3, specifically versions 1.015R–1.095Z, with a vulnerability in hard-coded passwords that could allow a remote, unauthenticated attacker to obtain information about the MELSEC safety CPU module project file. The vulnerability is documented with a...
CVE-2022-29828
The CVE-2022-29828 issue affects Mitsubishi Electric GX Works3, with versions starting at 1.000A and later; the root cause is a hard-coded cryptographic key that could allow remote, unauthenticated attackers to disclose sensitive information and potentially view or execute programs. According to ...
CVE-2022-29827
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally...
Design/Logic Flaw
A vulnerability has been identified in Micro Focus Filr in versions prior to 4.3.1.1. The vulnerability could be exploited to allow a remote unauthenticated attacker to enumerate valid users of the system. Remote unauthenticated user enumeration. This issue affects: Micro Focus Filr versions prio...
CVE-2022-38755
Vulnerability summary (CVE-2022-38755) : Micro Focus Filr versions prior to 4.3.1.1 are affected by a remote, unauthenticated user-enumeration flaw. Attackers can enumerate valid user accounts without authentication. The issue is confirmed across multiple sources (NVD/Red Hat/ CVE listings). Impa...
Mitsubishi (CVE-2022-33322)
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator...
CVE-2022-38201
An unvalidated redirect vulnerability exists in Esri Portal for ArcGIS Quick Capture Web Designer versions 10.8.1 to 10.9.1. A remote, unauthenticated attacker can potentially induce an unsuspecting authenticated user to access an an attacker controlled domain...
CVE-2022-38650
A remote unauthenticated insecure deserialization vulnerability exists in VMware Hyperic Server 5.8.6. Exploitation of this vulnerability enables a malicious party to run arbitrary code or malware within Hyperic Server and the host operating system with the privileges of the Hyperic server proces...
CVE-2022-38650
A remote unauthenticated insecure deserialization vulnerability exists in VMware Hyperic Server 5.8.6. Exploitation of this vulnerability enables a malicious party to run arbitrary code or malware within Hyperic Server and the host operating system with the privileges of the Hyperic server proces...