Lucene search
+L

4259 matches found

Cvelist
Cvelist
•added 2025/07/21 9:29 a.m.•46 views

CVE-2025-41675 Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization

A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command...

7.2CVSS0.00653EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/07/21 9:29 a.m.•24 views

CVE-2025-41674 Remote Command Injection in diagnostic Action Due to Improper Input Neutralization

A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command...

7.2CVSS0.00653EPSS
SaveExploits1References1
CVE
CVE
•added 2025/07/21 9:29 a.m.•43 views

CVE-2025-41674

The CVE-2025-41674 entry matches an OS command injection in MB CONNECT LINE mbNET.mini (industrial router) and Helmholz REX100/mbNET.mini family where improper neutralization of special elements in OS commands enables remote execution of commands via POST to a diagnostic action. Connected sources...

7.2CVSS7.2AI score0.00653EPSS
SaveExploits1References2Affected Software1
Vulnrichment
Vulnrichment
•added 2025/07/21 9:29 a.m.•8 views

CVE-2025-41674 Remote Command Injection in diagnostic Action Due to Improper Input Neutralization

A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command...

7.2CVSS7.8AI score0.00653EPSS
SaveExploits1References1
CVE
CVE
•added 2025/07/21 9:29 a.m.•40 views

CVE-2025-41673

CVE-2025-41673 affects MB CONNECT LINE mbNET.mini (industrial router). The vulnerability is an OS command-injection in the send_sms operation caused by improper neutralization of special elements, enabling remote execution of system commands via POST requests. Vulnerable versions are prior to 2.3...

7.2CVSS7.2AI score0.00653EPSS
SaveExploits1References2Affected Software1
Vulnrichment
Vulnrichment
•added 2025/07/21 9:29 a.m.•7 views

CVE-2025-41673 Remote Command Injection in send_sms Action Due to Improper Input Neutralization

A high privileged remote attacker can execute arbitrary system commands via POST requests in the sendsms action due to improper neutralization of special elements used in an OS command...

7.2CVSS7.8AI score0.00653EPSS
SaveExploits1References1
Cvelist
Cvelist
•added 2025/07/21 9:29 a.m.•26 views

CVE-2025-41673 Remote Command Injection in send_sms Action Due to Improper Input Neutralization

A high privileged remote attacker can execute arbitrary system commands via POST requests in the sendsms action due to improper neutralization of special elements used in an OS command...

7.2CVSS0.00653EPSS
SaveExploits1References1
VulnCheck KEV
VulnCheck KEV
•added 2025/07/21 12:00 a.m.•29 views

VulnCheck KEV: CVE-2023-5683

A vulnerability was found in Byzoro Smart S85F Management Platform up to 20231010 and classified as critical. This issue affects some unknown processing of the file /sysmanage/importconf.php. The manipulation of the argument btnfilerenew leads to os command injection. The attack may be initiated...

9.8CVSS5.5AI score0.1798EPSS
SaveIn wildExploits1References2
OSV
OSV
•added 2025/07/19 5:15 p.m.•22 views

CVE-2025-7836

A vulnerability has been found in D-Link DIR-816L up to 2.06B01 and classified as critical. Affected by this vulnerability is the function lxmldbcsystem of the file /htdocs/cgibin of the component Environment Variable Handler. The manipulation leads to command injection. The attack can be launche...

8.8CVSS5.5AI score0.06129EPSS
SaveExploits1References5
CVE
CVE
•added 2025/07/18 3:02 p.m.•47 views

CVE-2025-7788

CVE-2025-7788 affects Xuxueli xxl-job up to 3.1.1. The vulnerable component is the commandJobHandler function in SampleXxlJob.java, enabling OS command injection with remote access. Exploit-public disclosures exist. Remediation: upgrade to a version beyond 3.1.1 and, as a workaround, restrict acc...

8.8CVSS7.2AI score0.04879EPSS
SaveExploits1References4Affected Software1
Positive Technologies
Positive Technologies
•added 2025/07/18 12:00 a.m.•15 views

PT-2025-30007 · Ubiquiti · Unifi Access +1

Name of the Vulnerable Software and Affected Versions: UniFi Access Reader Pro versions 2.14.21 and earlier UniFi Access G2 Reader Pro versions 1.10.32 and earlier UniFi Access G3 Reader Pro versions 1.10.30 and earlier UniFi Access Intercom versions 1.7.28 and earlier UniFi Access G3 Intercom...

9.8CVSS8.1AI score0.01205EPSS
SaveExploits0References6
RedhatCVE
RedhatCVE
•added 2025/07/16 12:16 a.m.•34 views

CVE-2025-7553

A vulnerability classified as critical has been found in D-Link DIR-818LW up to 20191215. This affects an unknown part of the component System Time Page. The manipulation of the argument NTP Server leads to os command injection. It is possible to initiate the attack remotely. The exploit has been...

7.2CVSS5.3AI score0.03747EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/07/15 12:00 a.m.•79 views

PT-2025-34152

Name of the Vulnerable Software and Affected Versions: Linksys RE6250 versions 1.0.013.001 through 1.2.07.001 Linksys RE6300 versions 1.0.013.001 through 1.2.07.001 Linksys RE6350 versions 1.0.013.001 through 1.2.07.001 Linksys RE6500 versions 1.0.013.001 through 1.2.07.001 Linksys RE7000 version...

9CVSS6.6AI score0.06715EPSS
SaveExploits1References11
OSV
OSV
•added 2025/07/14 4:15 p.m.•17 views

CVE-2025-7615

A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. Affected by this vulnerability is the function clearPairCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. The attack can be...

8.8CVSS5.7AI score0.02424EPSS
SaveExploits1References6
OSV
OSV
•added 2025/07/14 3:15 p.m.•16 views

CVE-2025-7613

A vulnerability was found in TOTOLINK T6 4.1.5cu.748. It has been rated as critical. This issue affects the function CloudSrvVersionCheck of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. The attack may be...

8.8CVSS5.8AI score0.02424EPSS
SaveExploits1References6
VulnCheck KEV
VulnCheck KEV
•added 2025/07/13 12:00 a.m.•28 views

VulnCheck KEV: CVE-2024-0292

A vulnerability classified as critical has been found in Totolink LR1200GB 9.1.0u.6619B20230130. Affected is the function setOpModeCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to os command injection. It is possible to launch the attack remotely. The explo...

9.8CVSS5.5AI score0.04909EPSS
SaveIn wildExploits1References4
CVE
CVE
•added 2025/07/10 8:32 p.m.•56 views

CVE-2025-7414

CVE-2025-7414 affects Tenda O3V2 1.0.0.12(3880). The vulnerability is in the httpd component’s file /goform/setPingInfo, specifically the fromNetToolGet function, where manipulation of the domain argument leads to operating system command injection. This can be exploited remotely and publicly dis...

8.8CVSS6.5AI score0.1262EPSS
SaveIn wildExploits1References6Affected Software1
OSV
OSV
•added 2025/07/10 2:15 p.m.•17 views

CVE-2025-7407

A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument hostname leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to th...

8.8CVSS5.6AI score0.12128EPSS
SaveExploits1References6
OSV
OSV
•added 2025/07/06 4:15 p.m.•14 views

CVE-2025-7083

A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. This affects the function mp of the file /goform/mp of the component webs. The manipulation of the argument command leads to os command injection. It is possible to initiate the attack remotely. The exploit h...

8.8CVSS5.6AI score0.4627EPSS
SaveExploits1References5
CVE
CVE
•added 2025/07/06 3:32 p.m.•61 views

CVE-2025-7083

CVE-2025-7083 affects Belkin F9K1122 with firmware 1.00.33. A vulnerability in the function mp of the file /goform/mp allows OS command injection via manipulation of the command argument, with remote exploitation possible. The CVE entries consistently describe a critical impact (CWE-like risk: ar...

8.8CVSS6.3AI score0.4627EPSS
SaveIn wildExploits1References5Affected Software1
Rows per page
Query Builder