115 matches found
ABB Relion 650 and 670 Series Input Validation Error Vulnerability
The ABB Relion 670 Series and ABB Relion 650 Series are both transmission protection control devices from ABB Switzerland. An input validation error vulnerability exists in the ABB Relion 650 and 670 Series, which can be exploited by an attacker to reboot the device, resulting in a denial of...
ABB Relion 650 and 670 Series CVE-2019-18247 Denial Of Service Vulnerability
Description ABB Relion 650 and 670 Series are prone to a denial-of-service vulnerability. Attackers can exploit this issue to cause a device to reboot, denying service to legitimate users. The following versions of ABB Relion series are vulnerable: ABB Relion 650 series versions 1.3.0.5 and prior...
ABB Relion 670 Series
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: ABB Equipment: Relion 670 Series Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to read and delete files on the device. 3...
ABB Relion 650 and 670 Series
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: ABB Equipment: Relion 650 and 670 Series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to reboot the device,...
Abb Relion Improper Input Validation
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message. File data ot500307.nasl...
ABB Relion 670 Series CVE-2019-18253 Directory Traversal Vulnerability
Description ABB Relion 670 Series is prone to a directory-traversal vulnerability. Remote attackers may use a specially crafted request with directory-traversal sequences '../' to retrieve sensitive information. This may aid in further attacks. The following ABB products are affected: Relion 670...
delft (>=0.2.3 <=0.2.4), keras-textclassification (=0.1.6) +11 more potentially affected by CVE-2019-9635 via tensorflow-gpu (>=1.10.1 <=1.12.0)
tensorflow-gpu PYPI version =1.10.1, =0.2.3, =0.0.1, =0.0.1, =0.0.2 - monk-keras-cuda92 =0.0.1 - monk-keras-cuda92-test =0.0.1 - relion-yolo-it =0.1.3 Source cves: CVE-2019-9635 Source advisory: OSV:GHSA-MFG7-X5M7-6P8W...
ABB Relion 630 Denial of Service Vulnerability
The ABB Relion 630 is a relay device for substation automation protection and control from ABB Switzerland. A security vulnerability exists in the ABB Relion 630 version 1.1 before 1.1.0.C0, version 1.2 before 1.2.0.B3, and version 1.3 before 1.3.0.A6. A remote attacker could exploit this...
CVE-2018-20720
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message...
CVE-2018-20720
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message...
Design/Logic Flaw
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message...
CVE-2018-20720
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message...
CVE-2018-20720
Summary (CVE-2018-20720) Affected product: ABB Relion 630 devices. Vulnerable versions: 1.1 prior to 1.1.0.C0; 1.2 prior to 1.2.0.B3; 1.3 prior to 1.3.0.A6. Root cause / nature (as stated): Remote attackers can cause a denial of service (device reboot) via a reboot command in an SPA message. Impa...
PT-2019-10180 · Abb · Relion 630
Name of the Vulnerable Software and Affected Versions: ABB Relion 630 devices versions 1.1 through 1.1.0.C0 ABB Relion 630 devices versions 1.2 through 1.2.0.B3 ABB Relion 630 devices versions 1.3 through 1.3.0.A6 Description: The issue allows remote attackers to cause a denial of service,...
ABB Relion 650 Series OpenSSL Vulnerability (Update A)
OVERVIEW --------- Begin Update A Part 1 of 2-------- This updated advisory is a follow-up to the original advisory titled ICSA-14-126-01 ABB Relion 650 Series OpenSSL Vulnerability, that was published May 06, 2014, on the NCCIC/ICS-CERT web site. ABB has identified an OpenSSL vulnerability in it...