Lucene search
+L

12 matches found

BDU FSTEC
BDU FSTEC
•added 2026/09/07 12:00 a.m.•7 views

The vulnerability of SIPROTEC 5 devices, which are designed for relay protection, automation, and control, lies in their ability to load files of a harmful nature without limitation. This allows attackers to execute arbitrary codes or trigger malfunctions in the equipment.

The vulnerability of SIPROTEC 5 devices for relay protection, automation, and control is related to the unlimited loading of dangerous files. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code or cause service failures...

7.1CVSS7.1AI score0.00186EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2026/07/02 12:00 a.m.•18 views

The vulnerability of SIPROTEC 5 devices’ relay protection, automation, and control functions lies in the limited number of possible random values. This allows attackers to gain unauthorized access to the protected information.

The vulnerability of SIPROTEC 5 relay protection, automation, and control devices is related to the limited number of possible random values. Exploiting this vulnerability could allow an intruder, operating remotely, to gain unauthorized access to the protected information...

5.3CVSS7.2AI score0.00306EPSS
SaveExploits0References2Affected Software34
BDU FSTEC
BDU FSTEC
•added 2026/06/24 12:00 a.m.•15 views

The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices, related to pointer assignment errors, allows a intruder to trigger a service failure.

The vulnerability of the microprogramming software of Schneider Electric PowerLogic P7 relay protection devices relates to pointer assignment errors. Exploiting this vulnerability could allow an attacker to trigger a service failure...

7.8CVSS5.8AI score0.0046EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
•added 2026/02/10 12:00 a.m.•19 views

GE Vernova Enervista UR Setup 安全漏洞

GE Vernova Enervista UR Setup is an interface configuration and management software for relay protection devices developed by GE Vernova in the United States. Versions of GE Vernova Enervista UR Setup prior to version 8.6 contained security vulnerabilities, which were due to a vulnerability relat...

2.9CVSS5.8AI score0.00238EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2026/01/09 12:00 a.m.•8 views

The vulnerability of SIPROTEC relay protection devices lies in the insufficient protection of operational data during debugging code implementation, allowing attackers to execute arbitrary code.

The vulnerability of SIPROTEC relay protection devices is related to insufficient protection of service data during code debugging. Exploiting this vulnerability can allow attackers to execute arbitrary code...

7.2CVSS6.1AI score0.00314EPSS
SaveExploits0References2Affected Software36
BDU FSTEC
BDU FSTEC
•added 2026/01/09 12:00 a.m.•8 views

The vulnerability of SIPROTEC relay protection devices lies in the use of default login credentials, which allows attackers to gain unauthorized access to confidential information.

The vulnerability of SIPROTEC relay protection devices is related to the use of default login credentials. Exploiting this vulnerability could allow an attacker to gain unauthorized access to confidential information...

7.8CVSS5.8AI score0.00584EPSS
SaveExploits0References2Affected Software38
BDU FSTEC
BDU FSTEC
•added 2024/07/31 12:00 a.m.•14 views

The vulnerability of SIPROTEC relay protection devices, related to insufficiently secure data encryption, allows attackers to carry out “man-in-the-middle” attacks.

The vulnerability of SIPROTEC relay protection devices is related to insufficiently secure data encryption. Exploiting this vulnerability allows a malicious actor, operating remotely, to carry out “man-in-the-middle” attacks using specially crafted packets sent to port 4443/tcp...

7.1CVSS7.2AI score0.00205EPSS
SaveExploits0References2Affected Software35
BDU FSTEC
BDU FSTEC
•added 2023/05/31 12:00 a.m.•13 views

The vulnerability of the microprogramming software in Schneider Electric Easergy P40 relay protection and control devices allows a intruder to manipulate network traffic.

The vulnerability of microprogrammed software in relay protection and control devices from Schneider Electric’s Easergy P40 lies in the use of rigidly encrypted account data. Exploiting this vulnerability could allow a malicious actor to manipulate network traffic remotely...

7.1CVSS7.7AI score0.01071EPSS
SaveExploits0References3
CNVD
CNVD
•added 2023/04/16 12:00 a.m.•103 views

Siemens SICAM A8000 Command Injection Vulnerability

The Siemens SICAM A8000 is a protection and interval control unit device for relay protection and substation environments from Siemens, Germany. A command injection vulnerability exists in the Siemens SICAM A8000. The vulnerability stems from the device's failure to properly filter constructed...

9.8AI score0.02836EPSS
SaveExploits1
CNNVD
CNNVD
•added 2023/04/11 12:00 a.m.•35 views

Siemens SICAM A8000 命令注入漏洞

The Siemens SICAM A8000 is a protection and interval control unit device for relay protection and substation environments from Siemens, Germany. A command injection vulnerability exists in the Siemens SICAM A8000. The vulnerability stems from the device's failure to properly filter constructed...

9.8CVSS8.2AI score0.02836EPSS
SaveExploits1References5
BDU FSTEC
BDU FSTEC
•added 2022/03/18 12:00 a.m.•15 views

The vulnerability of the microprogramming software in Schneider Electric Easergy P5 relay protection and control devices, related to errors in SSH-key management, allows attackers to gain unauthorized access to protected information.

The vulnerability of the microprogramming software in Schneider Electric Easergy P5 relay protection and control devices is related to errors in managing SSH keys. Exploiting this vulnerability can allow attackers to gain unauthorized access to protected information...

7.5CVSS7.4AI score0.02371EPSS
SaveExploits0References4Affected Software1
CNVD
CNVD
•added 2015/11/26 12:00 a.m.•16 views

Eaton Form 6 control and Idea/IdeaPLUS information disclosure vulnerabilities

Eaton Form 6 control and Idea/IdeaPLUS are both products of the American company Eaton. The former is a controller product that provides instant access to operations and quickly determines the status of equipment as well as finding equipment faults, while the latter is a set of relay protection...

5.3CVSS6.6AI score0.01113EPSS
SaveExploits0References1
Rows per page
Query Builder