103 matches found
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2019-25724
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25724
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25724
The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...
EUVD-2019-20158
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25721
CVE-2019-25721 affects Dräger Infinity M300 patient-worn monitors with software VG2.3.1 and earlier. The issue is a network‑based denial-of-service vulnerability that lets network-adjacent attackers repeatedly trigger device reboots by sending malicious requests over the Infinity Network, forcing...
CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
EUVD-2019-20157
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
PT-2026-45813
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2026-9796
A flaw was found in Keycloak. An authenticated administrator with the manage-clients role can exploit a Time-of-check to time-of-use TOCTOU vulnerability in the name-based admin role checks. This allows the attacker to escalate their privileges to realm-admin for all users within the realm,...
CVE-2026-32839
Edimax GS-5008PL firmware version 1.00.54 and prior contain a cross-site request forgery vulnerability that allows remote attackers to perform unauthorized administrative actions by inducing logged-in administrators to visit malicious pages. Attackers can exploit the lack of anti-CSRF tokens and...
PT-2026-7632
Name of the Vulnerable Software and Affected Versions Palo Alto Networks PAN-OS versions affected versions not specified Description A denial-of-service DoS condition exists in the Advanced DNS Security ADNS feature of Palo Alto Networks PAN-OS software. An unauthenticated attacker can exploit th...
CVE-2026-0919
The HTTP parser of Tapo C210 v3, C220 v1 and C520WS v2 cameras improperly handles requests containing an excessively long URL path. An invalid‑URL error path continues into cleanup code that assumes allocated buffers exist, leading to a crash and service restart. An unauthenticated attacker can...
CVE-2025-9279
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limit Storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds...
CVE-2025-9466
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds...
CVE-2025-9466
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds...
CVE-2025-9465
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds...
CVE-2025-9282
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive limited storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds...