Lucene search
K

5848 matches found

EUVD
EUVD
added 6 days ago7 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00059EPSS
Exploits0References3
Positive Technologies
Positive Technologies
added 6 days ago5 views

PT-2026-46012

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score0.00024EPSS
Exploits0References9
Positive Technologies
Positive Technologies
added 6 days ago6 views

PT-2026-45983

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score0.00024EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 6 days ago5 views

Linux Distros Unpatched Vulnerability : CVE-2026-46249

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist...

5.5AI score0.00024EPSS
Exploits0References3
CVE
CVE
added last week11 views

CVE-2022-4992

CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...

8.8CVSS5.8AI score0.00059EPSS
Exploits0References2
Cvelist
Cvelist
added last week29 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00059EPSS
Exploits0References2
NVD
NVD
added last week5 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.0002EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added last week7 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.0002EPSS
Exploits0References2
EUVD
EUVD
added last week6 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.0002EPSS
Exploits0References2
Cvelist
Cvelist
added last week29 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.0002EPSS
Exploits0References2
CVE
CVE
added last week8 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00054EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added last week6 views

CVE-2019-25722

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00054EPSS
Exploits0References4
Vulnrichment
Vulnrichment
added last week5 views

CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00054EPSS
Exploits0References2
NVD
NVD
added last week11 views

CVE-2026-1871

TP-Link Tapo C200 v5 contains a stack-based buffer overflow flaw in RTSP authentication handling due to improper validation of Authorization header field lengths, which can be triggered by a crafted authentication request. Successful exploitation causes the affected RTSP core service process to...

7.1CVSS0.00038EPSS
Exploits0References4
ATTACKERKB
ATTACKERKB
added last week5 views

CVE-2026-1871

TP-Link Tapo C200 v5 contains a stack-based buffer overflow flaw in RTSP authentication handling due to improper validation of Authorization header field lengths, which can be triggered by a crafted authentication request. Successful exploitation causes the affected RTSP core service process to...

7.1CVSS6.1AI score0.00038EPSS
Exploits0References5
CVE
CVE
added last week7 views

CVE-2026-1871

CVE-2026-1871 affects TP-Link Tapo C200 v5. The issue is a stack-based buffer overflow in the RTSP authentication handling caused by improper validation of Authorization header lengths. Exploitation triggers a crash of the RTSP core service and an automatic system reboot, resulting in a DoS that ...

7.1CVSS6.1AI score0.00038EPSS
Exploits0References4Affected Software1
EUVD
EUVD
added last week6 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00022EPSS
Exploits0References2
Cvelist
Cvelist
added last week33 views

CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00022EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added last week6 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00022EPSS
Exploits0References4
Positive Technologies
Positive Technologies
added 2026/06/02 12:0 a.m.7 views

PT-2026-45739

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00022EPSS
Exploits0References3
Rows per page