2559 matches found
CVE-2021-20591
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules R00/01/02CPU all versions, R04/08/16/32/120ENCPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions allows a remote unauthenticated...
CVE-2021-20597
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a...
CVE-2021-21911
A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 30.07.2021. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger...
CVE-2021-21917
An exploitable SQL injection vulnerability exist in the ‘grouplist’ page of the Advantech R-SeeNet 2.4.15 30.07.2021. A specially-crafted HTTP request at '‘ord’ parameter. An attacker can make authenticated HTTP requests to trigger this vulnerability. This can be done as any authenticated user or...
CVE-2021-21916
An exploitable SQL injection vulnerability exist in the ‘grouplist’ page of the Advantech R-SeeNet 2.4.15 30.07.2021. A specially-crafted HTTP request at 'descriptionfilter’ parameter. An attacker can make authenticated HTTP requests to trigger this vulnerability. This can be done as any...
CVE-2021-21910
A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 30.07.2021. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger...
CVE-2021-21803
This vulnerability is present in devicegraphpage.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution...
CVE-2021-21805
An OS Command Injection vulnerability exists in the ping.php script functionality of Advantech R-SeeNet v 2.4.12 20.10.2020. A specially crafted HTTP request can lead to arbitrary OS command execution. An attacker can send a crafted HTTP request to trigger this vulnerability...
CVE-2021-21801
This vulnerability is present in devicegraphpage.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution...
CVE-2021-21800
Cross-site scripting vulnerabilities exist in the sshform.php script functionality of Advantech R-SeeNet v 2.4.12 20.10.2020. If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a craft...
CVE-2021-21802
This vulnerability is present in devicegraphpage.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution...
CVE-2021-20600
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS condition by sending a large number of packets in a short time while the module...
CVE-2021-21912
A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 30.07.2021. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger...
CVE-2021-21799
Cross-site scripting vulnerabilities exist in the telnetform.php script functionality of Advantech R-SeeNet v 2.4.12 20.10.2020. If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a...
CVE-2020-5657
Improper neutralization of argument delimiters in a command 'Argument Injection' vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Modul...
CVE-2020-5668
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 EN CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier,...
CVE-2020-5655
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...
CVE-2020-5652
Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 EN CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU...
CVE-2020-5658
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...
CVE-2020-5654
Session fixation vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96...