2160 matches found
CVE-2019-6806
Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs are affected by CVE-2019-6806, a CWE-200 information-exposure vulnerability. The issue stems from UMAS/Modbus read paths that can disclose SNMP information, including read/write/trap SNMP strings, when reading variables in the contr...
CVE-2018-7857
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus...
CVE-2018-7857
CVE-2018-7857 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. It is described as CWE-248 Uncaught Exception: writing out-of-bounds variables to the controller over Modbus can cause a Denial of Service . The entry lists CVSSv3.1 base score 7.5 (HIGH) and CVSSv2 5.0 (MEDIU...
CVE-2018-7856
The CVE-2018-7856 entry concerns Schneider Electric Modicon PLCs (M580, M340, Quantum, Premium). The vulnerability is a CWE-248 Uncaught Exception leading to potential denial of service when writing invalid memory blocks to the controller over Modbus. Affected software/hardware is the Modicon fam...
CVE-2018-7855
CVE-2018-7855 affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. The root cause is an uncaught exception when handling invalid breakpoint parameters sent over Modbus, which can trigger a Denial of Service with partial availability impact. Connected documents confirm the affe...
CVE-2018-7854
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus...
CVE-2018-7854
CVE-2018-7854 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. The issue is a CWE-248 Uncaught Exception that can cause denial of service when invalid debug parameters are sent over Modbus. The provided documents confirm affected models and the root cause (uncaught except...
CVE-2018-7853
CVE-2018-7853 affects Schneider Electric Modicon PLCs (M580, M340, Quantum, Premium). The vulnerability is a CWE-248 Uncaught Exception that could cause a denial of service when the controller reads invalid physical memory blocks over Modbus. The NVD entry lists CVSS-3.1 base metrics: Network att...
CVE-2018-7852
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus...
CVE-2018-7845
CVE-2018-7845 affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. The vulnerability is CWE-125: Out-of-bounds Read, allowing disclosure of unexpected data when reading specific memory blocks over Modbus. Impact is data disclosure; no exploitation details are provided in the ...
CVE-2018-7850
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software...
CVE-2018-7850
CVE-2018-7850 affects Schneider Electric Modicon controllers (M580, M340, Quantum, Premium) and relates to CWE-807 (Reliance on Untrusted Inputs in a Security Decision). The vulnerability could cause invalid information displayed in Unity Pro software due to a trust boundary issue in input handli...
CVE-2018-7847
CVE-2018-7847 affects Schneider Electric Modicon M580/M340/Quantum/Premium PLCs via Modbus; Talos confirms an unauthenticated UMAS file-write vulnerability in Modicon M580 firmware SV2.70 that can overwrite the device strategy/configuration, potentially enabling code execution and wide impact. Th...
CVE-2018-7842
The CVE-2018-7842 issue affects Schneider Electric Modicon M580, M340, Quantum, and Premium PLCs. Root cause: CWE-290 Authentication Bypass by Spoofing enabling brute-forcing of Modbus parameters to gain elevated privileges. Impact: elevation of privilege and potential unauthorized control of dev...
CVE-2018-7848
CVE-2018-7848 is an information-disclosure flaw in Schneider Electric Modicon controllers (M580, M340, Quantum, Premium) exploitable via the UMAS strategy read path. A specially crafted UMAS read of the programmed strategy (function code 0x34) can reveal plaintext SNMP community strings and other...
CVE-2018-7843
CVE-2018-7843 concerns Schneider Electric Modicon PLCs (M580, M340, Quantum, Premium) with a flaw in the UMAS memory block read path over Modbus. The public Talos analysis describes an out-of-bounds memory read in the MEMORY_BLOCK_READ function that can trigger a non-recoverable fault, potentiall...
CVE-2018-7849
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus...
CVE-2018-7849
The CVE-2018-7849 vulnerability affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. A CWE-248 Uncaught Exception could trigger a Denial of Service due to improper data integrity checks when sending files via Modbus. Affected firmware observed in Modicon M580 SV2.70 (e.g., BME...
CVE-2018-7846
CVE-2018-7846 affects Schneider Electric Modicon M580, M340, Quantum and Premium PLCs. The issue is a CWE-501 Trust Boundary Violation in the UMAS/Reservation mechanism: an unauthenticated brute-force attempt to the Modbus-based reservation session (one-byte session token) can allow unauthorized ...
CVE-2019-6816
The CVE-2019-6816 entry concerns Schneider Electric Modicon Quantum controllers. A CWE-94 Code Injection flaw exists in all firmware versions, enabling unauthorized firmware modification and potential Denial of Service when operating over Modbus. The publicly documented impact is partial integrit...