Lucene search
+L

6 matches found

Vulnrichment
Vulnrichment
•added 2026/04/08 12:00 a.m.•10 views

CVE-2025-50646

A buffer overflow vulnerability exists in D-Link DI-8003 16.07.26A1 due to insufficient input validation on the name parameter in the /qostypeasp.asp endpoint...

7.4AI score0.00516EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/04/08 12:00 a.m.•13 views

PT-2026-31372

Name of the Vulnerable Software and Affected Versions D-Link DI-8003 version 16.07.26A1 Description A buffer overflow exists due to inadequate input validation on the name parameter within the '/qos type asp.asp' API endpoint. Recommendations Ensure proper input validation is implemented for the...

7.8CVSS7.4AI score0.00516EPSS
SaveExploits0References7
NVD
NVD
•added 2026/02/19 1:16 p.m.•15 views

CVE-2019-25416

Comodo Dome Firewall 2.7.0 contains a reflected cross-site scripting vulnerability that allows attackers to inject malicious scripts by submitting crafted input through the device parameter. Attackers can send POST requests to the QoS devices management endpoint with script payloads in the device...

6.1CVSS0.00357EPSS
SaveExploits1References4
Cvelist
Cvelist
•added 2026/02/19 12:02 p.m.•48 views

CVE-2019-25416 Comodo Dome Firewall 2.7.0 Reflected Cross-Site Scripting via device Parameter

Comodo Dome Firewall 2.7.0 contains a reflected cross-site scripting vulnerability that allows attackers to inject malicious scripts by submitting crafted input through the device parameter. Attackers can send POST requests to the QoS devices management endpoint with script payloads in the device...

6.1CVSS0.00357EPSS
SaveExploits1References4
CVE
CVE
•added 2026/02/19 12:02 p.m.•30 views

CVE-2019-25416

CVE-2019-25416 affects Comodo Dome Firewall 2.7.0, where a reflected cross-site scripting vulnerability exists in the device parameter. The issue arises when an attacker submits crafted input to the QoS devices management endpoint via POST requests, enabling execution of arbitrary JavaScript in u...

6.1CVSS6.2AI score0.00357EPSS
SaveExploits1References4Affected Software1
EUVD
EUVD
•added 2026/02/08 8:02 a.m.•15 views

EUVD-2026-5806

A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function sub420688 of the file /goform/setqos. Executing a manipulation can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be us...

8.6CVSS6.9AI score0.06033EPSS
SaveExploits1References5
Rows per page
Query Builder