163 matches found

CNVD
CNVD
added 2022/05/12 12:0 a.m.15 views

Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37376)

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

5.3CVSS1AI score0.01012EPSS
SaveExploits0References1
ICS
ICS
added 2022/05/12 12:0 a.m.117 views

Siemens Desigo PXC and DXR Devices

1. EXECUTIVE SUMMARY CVSS v3 9.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: PXC and DXR Devices Vulnerabilities: Special Element Injection, Uncontrolled Resource Consumption, Use of Password Hash with Insufficient Computational Effort, Insufficient Session...

9.1CVSS8.3AI score0.01856EPSS
SaveExploits0References5
CNVD
CNVD
added 2022/05/11 12:0 a.m.77 views

Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-36376)

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

9.1CVSS0.8AI score0.00918EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:0 a.m.42 views

Siemens Desigo PXC and DXR Devices have unspecified vulnerabilities

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

6.5CVSS0.8AI score0.0045EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:0 a.m.19 views

Siemens Desigo PXC and DXR Devices Uncontrolled Resource Consumption Vulnerability

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

6.5CVSS1AI score0.00798EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:0 a.m.33 views

Siemens Desigo PXC and DXR Devices Remote Code Execution Vulnerability

The Desigo PXC4 building automation controller is designed for HVAC system control. It is a compact device with built-in IOs that can be expanded to meet your needs with additional TX-IO modules.The Desigo PXC5 is a freely programmable controller for BACnet system-level functions such as alarm...

9CVSS3.3AI score0.01856EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:0 a.m.62 views

Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37374)

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

6.5CVSS1AI score0.00573EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:0 a.m.59 views

Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37375)

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

7.5CVSS1AI score0.00844EPSS
SaveExploits0References1
OSV
OSV
added 2022/05/10 11:15 a.m.4 views

CVE-2022-24039

A vulnerability has been identified in Desigo PXC4 All versions V02.20.142.10-10884, Desigo PXC5 All versions V02.20.142.10-10884. The “addCell” JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such...

9CVSS7.4AI score0.01856EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/05/10 11:15 a.m.5 views

CVE-2022-24042

A vulnerability has been identified in Desigo DXR2 All versions V01.21.142.5-22, Desigo PXC3 All versions V01.21.142.4-18, Desigo PXC4 All versions V02.20.142.10-10884, Desigo PXC5 All versions V02.20.142.10-10884. The web application returns an AuthToken that does not expire at the defined auto...

9.1CVSS5.4AI score0.00918EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/05/10 12:0 a.m.27 views

Siemens Desigo PXC4 安全漏洞

The Desigo PXC4 building automation controller is designed for HVAC system control. It is a compact device with built-in IOs that can be expanded to meet your needs with additional TX-IO modules.The Desigo PXC5 is a freely programmable controller for BACnet system-level functions such as alarm...

9CVSS9AI score0.01856EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2022/05/10 12:0 a.m.6 views

PT-2022-2567 · Siemens · Desigo Pxc4 +1

Name of the Vulnerable Software and Affected Versions: Desigo PXC4 versions prior to V02.20.142.10-10884 Desigo PXC5 versions prior to V02.20.142.10-10884 Description: A vulnerability has been identified in the addCell JavaScript function, which fails to properly sanitize user-controllable input...

9CVSS9.2AI score0.01856EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2022/05/10 12:0 a.m.6 views

PT-2022-3425 · Siemens · Desigo Pxc4 +3

Name of the Vulnerable Software and Affected Versions: Desigo DXR2 versions prior to V01.21.142.5-22 Desigo PXC3 versions prior to V01.21.142.4-18 Desigo PXC4 versions prior to V02.20.142.10-10884 Desigo PXC5 versions prior to V02.20.142.10-10884 Description: A vulnerability has been identified i...

9.1CVSS9.1AI score0.00918EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/05/10 12:0 a.m.9 views

多款Siemens产品安全漏洞

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

7.5CVSS7.3AI score0.00868EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2022/04/20 12:0 a.m.13 views

The vulnerability of FTP servers for microprogrammed software controllers such as CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus allows a hacker to cause a service failure or execute arbitrary code.

The vulnerability of FTP servers for microprogrammed control devices such as CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors during the verification of the MKD/XMKD command length. Exploiting this vulnerability can allow an attack...

10CVSS8.1AI score0.02371EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/04/20 12:0 a.m.17 views

The vulnerability of FTP servers for microprogrammed software controllers such as CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus allows a hacker to cause service failures or execute arbitrary codes.

The vulnerability of the FTP servers of the microprogrammed control devices CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors during the verification of the USER command’s length. Exploiting this vulnerability can allow a remote...

10CVSS8.4AI score0.03031EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/04/20 12:0 a.m.11 views

The vulnerability of FTP servers for microprogrammed software controllers such as CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus allows a hacker to cause service failures or execute arbitrary codes.

The vulnerability of the FTP servers of the microprogrammed control devices CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors during the verification of the PWD/XPWD command length. Exploiting this vulnerability can allow an attacke...

10CVSS8.1AI score0.02371EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/04/20 12:0 a.m.15 views

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus relates to errors in processing TCP packet headers. This vulnerability allows attackers to gain access to protected information or cause service interruptions.

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors in processing the TCP header. Exploiting this vulnerability can allow an attacker to gain access to protected informatio...

9.4CVSS7.7AI score0.0215EPSS
SaveExploits0References4Affected Software2
BDU FSTEC
BDU FSTEC
added 2022/04/20 12:0 a.m.15 views

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus relates to errors in processing UDP packet headers. This vulnerability allows an attacker to gain access to protected information or cause a service failure.

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors in processing the UDP packet header. Exploiting this vulnerability can allow an attacker to gain access to protected...

9.4CVSS7.7AI score0.01578EPSS
SaveExploits0References6Affected Software2
BDU FSTEC
BDU FSTEC
added 2022/03/09 12:0 a.m.13 views

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus relates to errors in processing SACK TCP packets. This vulnerability allows an attacker to gain access to protected information or cause service interruptions.

The vulnerability of microprogrammed software for controllers CAPITAL VSTAR, APOGEE MBC, APOGEE MEC, APOGEE PXC, TALON TC, and the operating system Nucleus is related to errors in processing SACK TCP packets. Exploiting this vulnerability can allow a remote attacker to gain access to protected...

9.4CVSS7.8AI score0.02106EPSS
SaveExploits0References6Affected Software1