249 matches found
vDisk Lost Properties in PVS Console
vDisk lost properties in PVS consoleafter move vDisk to individual file server with MS DFS enabled,vDisk is shown as No server and filesize can not be identified...
PVS Imaging wizard failed to run on master target device
Error 1: PVS Imaging wizard failed to run with below error on master target device : The program can’t start because api-ms-win-crt-runtime-l1-1-0.dll is missing from your computer Error 2: imagingwizard.exe crashed when calling the following method: System.String.FormatSystem.IFormatProvider,...
How to assign VLANs to Targets created in PVS
This article explains the relationship between Networks and VLANs as it pertains to XenDesktop Hosting Units and PVS. The article also explains a workaround to be able to distribute Target Devices across desired VLANs The concept of VLAN IDs on the Hypervisor side is unknown to the XenDesktop...
Windows 10 PVS target devices experience poor performance
After capturing a Windows 10 vdisk you might experience below par performance when streaming the vdisk to the target device. The issue can manifest in a number of ways, for example: 1. Long time to capture the vdisk. 2. Slow boot/login times. 3. Slow file transfer speeds compared to other...
AppLayering 4.x - Unable to Publish Image to PVS - The operation timed out
When trying to publish an image in PVS, you will see the following error: 2017-11-15T16:04:11.104Z ERROR: pvs-connector/10307 on localhost.localdomain: reqNum=1663 c33700a0-ca47-11e7-af9c-83455e914109 - Operation 'pvs:UploadDiskOperation' has failed: Failed copying file to D:\xxxx\xxxxxxxxxx.vhd...
PVS 7.15 - Unable to boot target devices due to TFTP timeout error
While booting up PVS 7.15 target devices, it fails with "PXE - E32: TFTP open timeout"...
Configuration Wizard fails to complete properly
When running the configuration wizard, after finishing the process, the error shown below might be seen and the PVS server will not be joined correctly to the farm...
App Layering: Published image to PVS prompts user to restart computer
Customer publishes an image to PVS. When the machine boots up, it prompts for a restart with a box like this: "You must restart your computer to apply these changes." This is telling you that a new device has been detected and the driver has been installed, but Windows must restart to properly...
PVS Console | Fails to load farm\site\server details with error 'Server communication timeout'
The PVS Console throws following error while expanding farm\site\server details: 'Server communication timeout' MMC Console timeouts may also be seen. Now consider a Large AD Environment, where there are multiple Domains and the PVS Administrator User account used to access the PVS Console is par...
How to disable Interrupt Safe Mode in Provisioning Services
How to disable Interrupt Safe Mode in Provisioning Services The "Interrupt Safe Mode" configuration is a special setting designed to handle bad PXE implementations that do not comply with PXE standards or have bugs. The setting forces a reset on the UNDI Interface after sending every packet into...
Error "Hypervisor did not return the MAC address for this VM:Failed to connect to the remote server" in PVS Console
Getting an error message when attempting to create a vdisk within the vDisk Update Management in PVS console. Getting "Error Hypervisor VM Error. Hypervisor did not return the MAC address for this VM:Failed to connect to the remote server. Unable to locate server. The underlying connection was...
How to Defragment a PVS vDisk with minimum downtime
The purpose of this guide is to instruct a PVS Administrator on the quickest way to perform a defragmentation process on a vDisk, while minimizing the amount of downtime incurred for the PVS Targets. It is important to note that, while this process can be performed without having to Power Down th...
PVS7.15 - PVS configuration wizard "hangs" when configuring new farm
The PVS configuration wizard "hangs" when configuring new farm. This happens in case you have multiple domains...
Error 0x7B INACCESSIBLE_BOOT_DEVICE after installing PVS server on a Cisco UCS Server
After installing PVS Server software, or upgrading from a previous version, the first time the server reboots it will not be able to boot successfully anyomre. The server might present a Blue Screen with Error Code 0x7BINACCESSIBLEBOOTDEVICE...
Unable to Connect to PVS After PVS Server Upgrade or Downgrade
After an upgrade of PVS from 7.13 to 7.15, or a downgrade of the PVS server from 7.13 to 7.6, the ELM was no longer able to connect to it. Testing credentials would fail. Note, this probably happens in lots of other circumstances, but these are the two circumstances where we've seen this. If you...
KMS is not Activating Windows on PVS 7.1
PVS: 7.1 : KMS is not activating Windows...
PVS XDSW, Error: "(vsan) cannot complete file creation operation"
Symptoms: PVS console returns the error "vsan cannot complete file creation operation". CDF traces show exception "CreateWriteCacheDisk failed to CreateBlankVHD : Citrix.Xip.XipException: A general system error occurred: PBM error occurred during PreProcessReconfigureSpec: pbm.fault.PBMFault;Erro...
App Layering PVS Agent error registering to ELM "Could not create SSL/TLS secure channel"
When configuring the App Layering Provisioning Services PVS Agent on the PVS server, the error"Could not create SSL/TLS secure channel" occurs...
Unable to Configure Citrix App Layering ELM PVS Connector
The App Layering Agent PVS Agent on the PVS server is registered with the App Layering ELM virtual appliance, and the PVS Server enumerates on the App Layering PVS connector screen. However,clicking "check credentials" an error is displayed stating that the ELM cannot use the credentials on the P...