Lucene search
K

51 matches found

RedhatCVE
RedhatCVE
added 2025/10/09 1:13 a.m.2 views

CVE-2025-48981

An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection...

8.6CVSS6.9AI score0.00023EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/10/08 12:49 a.m.1 views

CVE-2025-48981

An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection...

6.5AI score0.00023EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/10/08 12:49 a.m.5 views

CVE-2025-48981

An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection...

0.00023EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/10/08 12:0 a.m.2 views

CompuGroup Medical MEDICO 安全漏洞

CompuGroup Medical MEDICO is a hospital information system software from CompuGroup Medical, Inc. A security vulnerability exists in CompuGroup Medical MEDICO that stems from an insecure implementation of DNET's proprietary protocol, which could lead to eavesdropping and manipulation of protocol...

8.6CVSS6.4AI score0.00023EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2017-6696

Malware in sbrugna...

7.5CVSS7.6AI score0.04438EPSS
Exploits3References2
EUVD
EUVD
added 2025/10/03 8:7 p.m.1 views

EUVD-2025-30227

Malicious code in bioql PyPI...

8.8CVSS6.5AI score0.00094EPSS
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/09/20 10:22 p.m.1 views

CVE-2025-53969

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a service implementing a proprietary protocol on TCP port 1069 to allow the client-side software, such as the In-Sight Explorer tool, to perform management operations such as changing network settings or modifying users' access to the...

8.8CVSS6.9AI score0.00094EPSS
Exploits0References1
NVD
NVD
added 2025/09/18 10:15 p.m.3 views

CVE-2025-54810

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channe...

8.6CVSS0.00028EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/09/18 12:0 a.m.1 views

Cognex In-Sight Explorer和Cognex In-Sight Camera Firmware 安全漏洞

Cognex In-Sight Explorer and Cognex In-Sight Camera Firmware are both products of Cognex Corporation, U.S.A. Cognex In-Sight Explorer is a tool that has the ability to debug and program the software of its line of smart cameras.Cognex In-Sight Camera Firmware is the firmware for a range of smart...

8.8CVSS6.5AI score0.00094EPSS
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/09/04 11:33 a.m.1 views

CVE-2025-52551

E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system...

9.3CVSS7AI score0.00082EPSS
Exploits0References1
NVD
NVD
added 2025/09/02 12:15 p.m.2 views

CVE-2025-52551

E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system...

9.3CVSS0.00082EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/09/02 11:30 a.m.1 views

CVE-2025-52551 Proprietary protocol allows for unauthenticated file operations

E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system...

9.3CVSS6.5AI score0.00082EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/09/02 11:30 a.m.5 views

CVE-2025-52551 Proprietary protocol allows for unauthenticated file operations

E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system...

9.3CVSS0.00082EPSS
Exploits0References1
CVE
CVE
added 2025/09/02 11:30 a.m.5 views

CVE-2025-52551

CVE-2025-52551 concerns Copeland E2 Facility Management Systems, where a proprietary protocol permits unauthenticated file operations on any file in the file system. The CVSS-based assessment in the initial record indicates a critical impact (high confidentiality, integrity, and availability impa...

9.3CVSS6.5AI score0.00082EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2025/09/02 12:0 a.m.2 views

PT-2025-35560

Name of the Vulnerable Software and Affected Versions: E2 Facility Management Systems affected versions not specified Description: E2 Facility Management Systems utilizes a proprietary protocol that permits unauthenticated file operations on any file within the file system. Recommendations: At th...

9.3CVSS6.3AI score0.00082EPSS
Exploits0References4
NVD
NVD
added 2025/03/14 1:15 p.m.4 views

CVE-2025-27594

The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack...

7.5CVSS0.00095EPSS
Exploits0References7
Cvelist
Cvelist
added 2025/03/14 12:50 p.m.10 views

CVE-2025-27594 Unencrypted transmission of password hash

The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack...

7.5CVSS0.00095EPSS
Exploits0References7
RedhatCVE
RedhatCVE
added 2025/02/06 12:6 a.m.9 views

CVE-2022-47311

A proprietary protocol for iBoot devices is used for control and keepalive commands. The function compares the username and password; it also contains the configuration data for the user specified. If the user does not exist, then it sends a value for username and password, which allows successfu...

8.8CVSS7.1AI score0.00185EPSS
Exploits0
The Hacker News
The Hacker News
added 2023/07/14 2:41 p.m.87 views

Critical Security Flaws Uncovered in Honeywell Experion DCS and QuickBlox Services

Multiple security vulnerabilities have been discovered in various services, including Honeywell Experion distributed control system DCS and QuickBlox, that, if successfully exploited, could result in severe compromise of affected systems. Dubbed Crit.IX, the nine flaws in the Honeywell Experion D...

9.8CVSS9.2AI score0.48696EPSS
Exploits4
NVD
NVD
added 2023/05/22 11:15 p.m.19 views

CVE-2022-47311

A proprietary protocol for iBoot devices is used for control and keepalive commands. The function compares the username and password; it also contains the configuration data for the user specified. If the user does not exist, then it sends a value for username and password, which allows successfu...

8.8CVSS8.9AI score0.00185EPSS
Exploits0References2
Rows per page
Query Builder