80 matches found
PROMOTIC SCADA - Directory Traversal Detection (CVE-2011-4518)
Detects CVE-2011-4518 via /webdir/../../../../../../../../windows/win.ini. !/usr/bin/env python3 -- coding: utf-8 -- """Detects CVE-2011-4518 via /webdir/.""" import re from kittysploit import from lib.protocols.http.httpclient import Httpclient class ModuleScanner, Httpclient: info = 'name':...
Microsys Promotic SCADA - Login Panel Detection
Microsys Promotic is a SCADA/HMI software platform widely deployed in central European industrial and building automation applications. The embedded web server exposes a runtime panel accessible over HTTP on non-standard ports. !/usr/bin/env python3 -- coding: utf-8 -- """Microsys Promotic is a...
EUVD-2011-4444
Malware in sbrugna...
EUVD-2011-4445
Malware in sbrugna...
EUVD-2011-4791
Malware in sbrugna...
EUVD-2014-9030
Malware in sbrugna...
EUVD-2016-0880
Malware in sbrugna...
EUVD-2011-4446
Malware in sbrugna...
CVE-2014-1617
Microsys PROMOTIC 8.2.13 contains an ActiveX Control Start Buffer Overflow vulnerability which can lead to denial of service...
CVE-2011-4520
Heap-based buffer overflow in an ActiveX component in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to cause a denial of service via a crafted web page...
CVE-2011-4518
Directory traversal vulnerability in the PmWebDir object in the web server in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to read arbitrary files via unspecified vectors...
CVE-2011-4519
Stack-based buffer overflow in an ActiveX component in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to cause a denial of service via a crafted web page...
SUSE CVE-2014-9205
Stack-based buffer overflow in the PmBase64Decode function in an unspecified demonstration application in MICROSYS PROMOTIC stable before 8.2.19 and PROMOTIC development before 8.3.2 allows remote attackers to execute arbitrary code by providing a large amount of data...
CVE-2014-1617
Microsys PROMOTIC 8.2.13 contains an ActiveX Control Start Buffer Overflow vulnerability which can lead to denial of service...
Buffer overflow
Microsys PROMOTIC 8.2.13 contains an ActiveX Control Start Buffer Overflow vulnerability which can lead to denial of service...
CVE-2014-1617
Microsys PROMOTIC 8.2.13 contains an ActiveX Control Start Buffer Overflow vulnerability which can lead to denial of service...
CVE-2014-1617
CVE-2014-1617 affects Microsys PROMOTIC 8.2.13. A buffer overflow in the ActiveX control Start routine can cause denial of service. All available sources describe the vulnerability as a vulnerability in the PROMOTIC ActiveX component, but the provided documents do not specify exact exploit vector...
CVE-2014-1617: Buffer Copy without Checking Size of Input
Microsys PROMOTIC 8.2.13 contains an ActiveX Control Start Buffer Overflow vulnerability which can lead to denial of service...
PT-2020-7607
Name of the Vulnerable Software and Affected Versions Microsys PROMOTIC version 8.2.13 Description The issue is related to an ActiveX Control Start Buffer Overflow, which can lead to denial of service. Recommendations For Microsys PROMOTIC version 8.2.13, at the moment, there is no information...
MICROSYS PROMOTIC Memory Corruption Vulnerability
OVERVIEW Security researcher Praveen Darshanam of Versa Networks has identified a memory corruption vulnerability in the MICROSYS, spol. s r.o. PROMOTIC application. MICROSYS has produced a new version to mitigate this vulnerability. The researcher has tested the new version to validate that it...