17 matches found
CVE-2021-22647
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker t...
CVE-2023-25755
Screen Creator Advance 2 Ver.0.1.1.4 Build01A and earlier is vulnerable to improper restriction of operations within the bounds of a memory buffer CWE-119 due to improper check of its data size when processing a project file. If a user of Screen Creator Advance 2 opens a specially crafted project...
PT-2022-4635 · Measuresoft · Measuresoft Scadapro Server
Name of the Vulnerable Software and Affected Versions: Measuresoft ScadaPro Server All Versions Description: The issue is related to a use-after-free condition when processing a specific project file, which can allow an attacker to execute arbitrary code remotely. This is associated with the...
CVE-2022-25959
Omron CX-Position versions 2.5.3 and prior is vulnerable to memory corruption while processing a specific project file, which may allow an attacker to execute arbitrary code...
PT-2022-5876 · Omron · Omron Cx-Position
Name of the Vulnerable Software and Affected Versions: Omron CX-Position versions 2.5.3 and prior Description: The issue is related to an out-of-bounds write in memory, which can be exploited to execute arbitrary code. This occurs while processing a specific project file. Recommendations: For Omr...
Omron CX-Position 缓冲区错误漏洞
Omron CX-Position is a position control software from Omron Corporation of Japan. An out-of-bounds write vulnerability exists in Omron CX-Position, which stems from a failure to properly validate data when a program performs an operation in memory while processing a specific project file, and cou...
PT-2022-13861 · Delta Electronics · Cncsoft
Name of the Vulnerable Software and Affected Versions: Delta Electronics CNCSoft versions prior to 1.01.32 Description: The issue arises from improper input sanitization when processing a specific project file, leading to a possible out-of-bounds read condition. This can potentially result in...
CVE-2022-21137
Omron CX-One Versions 4.60 and prior are vulnerable to a stack-based buffer overflow while processing specific project files, which may allow an attacker to execute arbitrary code...
Out-of-bounds
FATEK Automation FvDesigner, Versions 1.5.88 and prior is vulnerable to an out-of-bounds write while processing project files, allowing an attacker to craft a project file that may permit arbitrary code execution...
CVE-2021-22670
An uninitialized pointer may be exploited in Fatek FvDesigner Version 1.5.76 and prior while the application is processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution...
CVE-2021-22638
Fatek FvDesigner Version 1.5.76 and prior is vulnerable to an out-of-bounds read while processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution...
CVE-2021-22653
Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite versions prior to 4.0.10.0...
CVE-2021-22639
An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite versions prior to 4.0.10.0...
CVE-2020-27287
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2018-19020
When CX-Supervisor Versions 3.42 and prior processes project files and tampers with the value of an offset, an attacker can force the application to read a value outside of an array...
CVE-2018-17909
When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application...
CVE-2018-17901
The CVE-2018-17901 entry concerns LAquis SCADA (versions 4.1.0.3870 and earlier). It describes a vulnerability in processing project files where input is not sanitized before write operations on a stack object, potentially allowing code to be executed in the context of the current process. Docume...