CVE-2021-32980

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS6.9AI score0.00285EPSS
Exploits0
NVD
NVD
added 2022/04/04 8:15 p.m.12 views

CVE-2021-32984

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...

9.8CVSS0.00285EPSS
Exploits0References1
Prion
Prion
added 2022/04/04 8:15 p.m.15 views

Authorization

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...

7.5CVSS9.2AI score0.00285EPSS
Exploits0References1Affected Software20
Vulnrichment
Vulnrichment
added 2022/04/04 7:45 p.m.6 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS6.9AI score0.00285EPSS
Exploits0References1
Cvelist
Cvelist
added 2022/04/04 7:45 p.m.14 views

CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS9.6AI score0.00285EPSS
Exploits0References1
CNNVD
CNNVD
added 2021/06/15 12:0 a.m.2 views

CLICK PLC CPU Modules 授权问题漏洞

CLICK PLC CPU Modules are Automation Direct's network devicesA single CLICK CPU Module can be connected to up to eight I/O modules to expand the number of system I/O and meet the needs of a specific application. An authorization issue vulnerability exists in Automation Direct CLICK PLC CPU Module...

9.8CVSS8.2AI score0.00285EPSS