599 matches found
CVE-2019-13946
Profinet-IO PNIO stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable...
CVE-2019-13946
The CVE-2019-13946 issue affects the PROFINET-IO (PNIO) stack in Siemens devices, specifically PNIO versions prior to V06.00. The root problem is uncontrolled internal resource allocation during multiple diagnostic package requests to the DCE-RPC interface, enabling a network-accessible attacker ...
CVE-2019-13946
Profinet-IO PNIO stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable...
PT-2020-2433 · Siemens · Profinet-Io
Name of the Vulnerable Software and Affected Versions: Profinet-IO PNIO stack versions prior to V06.00 Description: The issue is related to an uncontrolled resource consumption in the DCE-RPC interface of Siemens hardware and software. This could lead to a denial of service condition due to lack ...
Siemens PROFINET-IO Stack (Update H)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2019-13944
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
CVE-2019-13943
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Code injection
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
CVE-2019-13944
CVE-2019-13944 affects Siemens EN100 Ethernet Module family (DNP3, IEC61850
CVE-2019-13942
The CVE-2019-13942 issue affects Siemens EN100 Ethernet Module variants (DNP3, IEC61850
CVE-2019-13943
CVE-2019-13943 affects Siemens EN100 Ethernet Module variants (DNP3, IEC61850
PT-2019-13484 · Moxa · En100 Ethernet Module Modbus Tcp Variant +4
Name of the Vulnerable Software and Affected Versions: EN100 Ethernet module DNP3 variant All versions EN100 Ethernet module IEC 61850 variant All versions V4.37 EN100 Ethernet module IEC104 variant All versions EN100 Ethernet module Modbus TCP variant All versions EN100 Ethernet module PROFINET ...
CVE-2019-19707
On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices with firmware through 6.0, denial of service can occur via PROFINET DCE-RPC endpoint discovery packets...
CVE-2019-19707
On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices with firmware through 6.0, denial of service can occur via PROFINET DCE-RPC endpoint discovery packets...
Denial of service
On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices with firmware through 6.0, denial of service can occur via PROFINET DCE-RPC endpoint discovery packets...
CVE-2019-19707
CVE-2019-19707 affects Moxa EDS-G508E, EDS-G512E, and EDS-G516E Ethernet Switches (firmware up to 6.0). The issue enables denial-of-service via PROFINET DCE-RPC endpoint discovery packets, stemming from uncontrolled resource consumption. Impact is DoS on affected devices, potentially taking them ...
CVE-2019-19707
On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices with firmware through 6.0, denial of service can occur via PROFINET DCE-RPC endpoint discovery packets...
Siemens EN100 Ethernet Module (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: EN100 Ethernet Module Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer, Cross-site Scripting, Relative Path Traversal 2. UPDATE...
CVE-2019-5637
When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 and prior and TwinCAT 3.1 version 4204.0 and prior...
CVE-2019-5637
When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 and prior and TwinCAT 3.1 version 4204.0 and prior...