Lucene search
+L

112 matches found

OSV
OSV
added 2017/06/21 7:29 a.m.3 views

UBUNTU-CVE-2017-9766

In Wireshark 2.2.7, PROFINET IO data with a high recursion depth allows remote attackers to cause a denial of service stack exhaustion in the dissectIODWriteReq function in plugins/profinet/packet-dcerpc-pn-io.c...

7.5CVSS6.8AI score0.03822EPSS
Exploits0References4
CVE
CVE
added 2017/06/21 7:0 a.m.159 views

CVE-2017-9766

CVE-2017-9766 : In Wireshark, version 2.2.7 is vulnerable to a denial of service caused by stack exhaustion via PROFINET IO data with excessive recursion. The issue occurs in the dissect_IODWriteReq function (plugins/profinet/packet-dcerpc-pn-io.c). Remote attackers could trigger the vulnerabilit...

7.5CVSS7.1AI score0.03822EPSS
Exploits0References4Affected Software1
Cvelist
Cvelist
added 2017/06/21 7:0 a.m.40 views

CVE-2017-9766

In Wireshark 2.2.7, PROFINET IO data with a high recursion depth allows remote attackers to cause a denial of service stack exhaustion in the dissectIODWriteReq function in plugins/profinet/packet-dcerpc-pn-io.c...

7.2AI score0.03822EPSS
Exploits0References4
Tenable Nessus
Tenable Nessus
added 2017/06/14 12:0 a.m.10 views

Profinet IO UDP Protocol Detection With Big Endian Data Representation

Binary data 700184.prm...

7.3AI score
Exploits0
ICS
ICS
added 2017/05/09 12:0 a.m.34 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update H)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.01149EPSS
Exploits0References75
CNVD
CNVD
added 2016/11/17 12:0 a.m.3 views

Siemens SIMATIC S7-300 CPU Denial of Service Vulnerability

Siemens SIMATIC S7-300 CPU is a modular general-purpose controller for the manufacturing industry from Siemens, Germany, and is widely used in important industrial control sites such as tobacco, petrochemical, and water. A denial of service vulnerability exists in the Siemens SIMATIC S7-300 CPU.T...

6.6AI score
Exploits0
CVE
CVE
added 2016/09/06 12:0 a.m.65 views

CVE-2016-7114

Siemens SIPROTEC 4/Compact EN100 Ethernet module family is affected by CVE-2016-7114 (Improper Authentication). The vulnerability allows remote attackers with network access to the device web interface (port 80) to possibly circumvent authentication and perform administrative operations, requirin...

9CVSS9AI score0.02113EPSS
Exploits0References5Affected Software1
CVE
CVE
added 2016/09/06 12:0 a.m.62 views

CVE-2016-7112

CVE-2016-7112 is an Authentication Bypass vulnerability in the Siemens EN100 Ethernet module used with SIPROTEC 4/Compact and related equipment. Affected firmware variants PROFINET IO, Modbus TCP, DNP3 TCP, and IEC 104 in all SIPROTEC 4/Compact deployments allow remote attackers with access to th...

10CVSS9.3AI score0.0286EPSS
Exploits0References5Affected Software1
NVD
NVD
added 2016/05/31 1:59 a.m.13 views

CVE-2016-4785

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS7AI score0.02676EPSS
Exploits0References6
NVD
NVD
added 2016/05/31 1:59 a.m.23 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6AI score0.02676EPSS
Exploits0References6
NVD
NVD
added 2015/07/18 10:59 a.m.23 views

CVE-2015-5374

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS9.1AI score0.74323EPSS
Exploits7References6
CVE
CVE
added 2015/07/18 10:0 a.m.101 views

CVE-2015-5374

CVE-2015-5374 affects Siemens SIPROTEC 4/Compact devices with EN100 Ethernet modules (PROFINET IO, Modbus TCP, DNP3 TCP, IEC 104 firmware) and SIPROTEC 6MU80 integration. The flaw is an improper input validation that allows specially crafted UDP packets to port 50000 to cause a denial-of-service,...

7.8CVSS8.9AI score0.74323EPSS
Exploits7References6Affected Software1
Rows per page