91 matches found
CVE-2014-8513
CVE-2014-8513 affects Schneider Electric ProClima (ActiveX control MDraw30.ocx) with a buffer overflow vulnerability in ProClima before 6.1.7 that allows remote code execution via unspecified vectors. The issue is distinct from CVE-2014-8514 and CVE-2014-9188. Remediation guidance in the sources ...
CVE-2014-8512
CVE-2014-8512 affects Schneider Electric ProClima (ATX45) via the Atx45.ocx ActiveX control. The vulnerability is a buffer overflow in the control before version 6.1.7 that could allow remote arbitrary code execution via unspecified vectors. Documented in multiple sources (e.g., ZDI advisories fo...
CVE-2014-9188
CVE-2014-9188 is a remote code execution vulnerability in Schneider Electric ProClima's MetaDraw ActiveX control (MDraw30.ocx) prior to version 6.1.7. The issue arises from a buffer overflow in the ActiveX control, with linked advisories detailing additional MetaDraw flaws (ArrangeObjects, ObjLin...
CVE-2014-8514
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...
CVE-2014-8511
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers...
CVE-2014-8512
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers...
CVE-2014-8513
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided b...
CVE-2014-8511
The CVE-2014-8511 issue affects Schneider Electric ProClima before 6.1.7, specifically the Atx45.ocx ActiveX control. A heap/buffer overflow within Atx45.ocx (documented variants reference SetHtmlFileName/SetBodyAttribute paths) can allow remote attackers to execute arbitrary code. This is report...
CVE-2014-9188 Schneider Electric ProClima Command Injection
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided b...
Critical Remotely Exploitable Bugs Found in Schneider Electric ProClima Software
There are a number of critical, remotely exploitable command injection vulnerabilities in Schneider Electric’s ProClima software, which is used in manufacturing and energy facilities. The ProClima application is a utility that customers use to design control panel enclosures in industrial...
Schneider Electric ProClima Command Injection Vulnerabilities
OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning command injection vulnerabilities in Schneider Electric’s ProClima software package. These vulnerabilities were reported to ZDI by security researchers Ariele Caltabiano, Andrea Micalizzi, and Brian Gorenc...