Lucene search
K

14 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2021-14150

Malware in sbrugna...

8.1CVSS8AI score0.00248EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/03 8:7 p.m.1 views

EUVD-2024-35556

Malicious code in bioql PyPI...

9.4CVSS8.9AI score0.00177EPSS
Exploits0References1
CNVD
CNVD
added 2025/08/22 12:0 a.m.1 views

Elevation of Privilege Vulnerability in Multiple SIEMENS Products

SIMATIC Information Server is used to report and visualize process data stored in SIMATIC Process Historian.SIMATIC PDM MS provides independent field device management, diagnostics, and data acquisition functions across a wide range of communication protocols that are independent of the automatio...

6.9AI score
Exploits0
RedhatCVE
RedhatCVE
added 2025/05/22 6:27 p.m.5 views

CVE-2021-27395

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1CVSS6.8AI score0.00248EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/02/04 10:13 p.m.4 views

CVE-2024-35783

A vulnerability has been identified in SIMATIC BATCH V9.1 All versions, SIMATIC Information Server 2020 All versions V2020 SP2 Update 5, SIMATIC Information Server 2022 All versions V2022 SP1 Update 2, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC06, SIMATIC Process Historian 2020 All versions V202...

9.4CVSS7.5AI score0.00177EPSS
Exploits0
Cvelist
Cvelist
added 2024/09/10 9:36 a.m.15 views

CVE-2024-35783

A vulnerability has been identified in SIMATIC BATCH V9.1 All versions, SIMATIC Information Server 2020 All versions V2020 SP2 Update 5, SIMATIC Information Server 2022 All versions V2022 SP1 Update 2, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC06, SIMATIC Process Historian 2020 All versions V202...

9.4CVSS0.00177EPSS
Exploits0References1
CVE
CVE
added 2024/09/10 9:36 a.m.47 views

CVE-2024-35783

CVE-2024-35783 affects Siemens SIMATIC SCADA/PCS7 family (e.g., SIMATIC BATCH, Information Server, PCS 7, Process Historian, WinCC variants). The root cause is privilege-management errors allowing the database server to run with elevated privileges, enabling an authenticated attacker to execute a...

9.4CVSS9.4AI score0.00177EPSS
Exploits0References1
CNVD
CNVD
added 2021/10/15 12:0 a.m.18 views

Siemens SIMATIC Process Historian Authentication Vulnerability

Siemens Simatic Process Historian is a centralized archiving system from Siemens, Germany. An authentication vulnerability exists in Siemens SIMATIC Process Historian, which arises from a lack of authentication of interfaces used for critical functions in the software, and can be exploited by an...

8.1CVSS8.1AI score0.00248EPSS
Exploits0References1
NVD
NVD
added 2021/10/12 10:15 a.m.8 views

CVE-2021-27395

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1CVSS0.00248EPSS
Exploits0References1
Prion
Prion
added 2021/10/12 10:15 a.m.8 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

5.5CVSS7.8AI score0.00248EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2021/10/12 9:49 a.m.44 views

CVE-2021-27395

CVE-2021-27395 affects Siemens SIMATIC Process Historian (versions 2013 and earlier; 2014 before SP3 Update 6; 2019; 2020). The issue is missing authentication on interfaces used for critical functions, enabling a malicious user to insert, modify, or delete data. CVSS v3 base score is 9.8 (vector...

8.1CVSS7.8AI score0.00248EPSS
Exploits0References1Affected Software4
Cvelist
Cvelist
added 2021/10/12 9:49 a.m.10 views

CVE-2021-27395

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier All versions, SIMATIC Process Historian 2014 All versions SP3 Update 6, SIMATIC Process Historian 2019 All versions, SIMATIC Process Historian 2020 All versions. An interface in the software that is used for critica...

8.1AI score0.00248EPSS
Exploits0References1
CNNVD
CNNVD
added 2021/10/12 12:0 a.m.2 views

Siemens Simatic Process Historian 访问控制错误漏洞

Siemens Simatic Process Historian is a centralized archiving system from Siemens, Germany. An authentication vulnerability exists in Siemens SIMATIC Process Historian, which arises from a lack of authentication of interfaces used for critical functions in the software, and can be exploited by an...

8.1CVSS5.7AI score0.00248EPSS
Exploits0References5
ICS
ICS
added 2021/10/12 12:0 a.m.37 views

Siemens SIMATIC Process Historian

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Process Historian Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could enable the execution of...

8.1CVSS8.6AI score0.00248EPSS
Exploits0References11
Rows per page
Query Builder