Lucene search
K

10 matches found

CNNVD
CNNVD
added 2025/03/25 12:0 a.m.2 views

B&R Industrial Automation B&R APROL 访问控制错误漏洞

B&R Industrial Automation B&R APROL is a process control system from B&R Industrial Automation, Austria. An access control error vulnerability exists in B&R Industrial Automation B&R APROL versions prior to 4.4-01, which stems from a lack of critical function authentication in the GRUB...

7CVSS6.7AI score0.00196EPSS
Exploits0References2
CNVD
CNVD
added 2024/04/10 12:0 a.m.3 views

Siemens SIMATIC WinCC Denial of Service Vulnerability (CNVD-2024-17302)

SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system.SIMATIC WinCC Runtime Professional is used for operator visualization of the runtime platform for the control and monitoring of machines and equipment. A denial of service...

6.9CVSS6.7AI score0.00051EPSS
Exploits0References1
ICS
ICS
added 2022/08/30 12:0 a.m.32 views

Hitachi Energy RTU500 series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause an internal buffer overflow, which can...

7.8CVSS7.9AI score0.00296EPSS
Exploits0References5
CNVD
CNVD
added 2022/05/11 12:0 a.m.49 views

Siemens SIMATIC WinCC Kiosk Mode Incorrect Initialization Vulnerability

SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system.SIMATIC WinCC Runtime Professional is a visual runtime platform for operators to control and monitor machines and equipment. A security vulnerability exists in Siemens SIMATIC WinC...

7.8CVSS6.7AI score0.00058EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2022/02/09 12:0 a.m.2 views

PT-2022-4092 · Siemens · Simatic Pcs 7 +1

Name of the Vulnerable Software and Affected Versions: SIMATIC PCS 7 versions V8.2 through V9.1 SIMATIC PCS 7 version V9.1 prior to V9.1 SP1 SIMATIC WinCC versions V7.4 through V7.4 prior to V7.4 SP1 Update 19 SIMATIC WinCC versions V7.5 through V7.5 prior to V7.5 SP2 Update 6 SIMATIC WinCC...

8.8CVSS8.2AI score0.00264EPSS
Exploits0References4
CNVD
CNVD
added 2021/11/13 12:0 a.m.25 views

Siemens SIMATIC PCS 7 and SIMATIC WinCC Path Traversal Vulnerability

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC, which stems...

7.7CVSS2.7AI score0.00406EPSS
Exploits0References1
CNVD
CNVD
added 2021/11/12 12:0 a.m.20 views

Siemens Product WIBU Systems CodeMeter Runtime Denial of Service Vulnerability

PSSRCAPE is a transmission and distribution network protection simulation software. pssRE i is a power system simulation and analysis tool for transmission operation and planning. pssRODMS i is a transmission network modeling and analysis tool. sicam 230 is a scalable process control system for a...

7.1CVSS6.8AI score0.00078EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 2021/11/09 12:0 a.m.3 views

PT-2021-22878 · Siemens · Simatic Pcs 7 +1

Name of the Vulnerable Software and Affected Versions: SIMATIC PCS 7 versions prior to V9.1 SP1 SIMATIC PCS 7 version V8.2 SIMATIC PCS 7 version V9.0 through V9.0 SP3 UC03 SIMATIC WinCC versions prior to V15 SP1 Update 7 SIMATIC WinCC versions prior to V16 Update 5 SIMATIC WinCC versions prior to...

5.5CVSS5.2AI score0.00052EPSS
Exploits0References3
NCSC
NCSC
added 2021/02/09 12:0 a.m.2 views

Vulnerability fixed in Simatic WinCC and PCS7

Siemens has fixed a vulnerability in Simatic WinCC Graphics Designer Tool and PCS7. a local malicious person could exploit it to gain access to a user, even any password-protected ones. To exploit the vulnerability, the malicious party needs physical access to the system where the vulnerable...

5.5CVSS6.8AI score0.00057EPSS
Exploits0
ThreatPost
ThreatPost
added 2014/06/04 3:19 p.m.8 views

COPA-DATA Patches DNP3 SCADA Vulnerability

A vulnerability exists in a particular brand of SCADA software that if left unpatched, could trigger a denial of service condition and go on to compromise the software’s communication connections, resulting in system instability. The problem is an improper input validation vulnerability and exist...

1.4AI score
Exploits0References3
Rows per page
Query Builder