Lucene search
+L

152 matches found

RedhatCVE
RedhatCVE
added 2025/02/05 11:30 p.m.24 views

CVE-2022-41669

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal ExpertV3.3...

7.8CVSS6.6AI score0.0011EPSS
Exploits0References1
CISA
CISA
added 2025/02/04 12:0 p.m.29 views

CISA Releases Nine Industrial Control Systems Advisories

CISA released nine Industrial Control Systems ICS advisories on February 4, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-035-01 Western Telematic Inc NPS Series, DSM Series, CPM Series ICSA-25-035-02 Rockwe...

7.1AI score
Exploits0References9
BDU FSTEC
BDU FSTEC
added 2025/01/21 12:0 a.m.7 views

The vulnerability of the microprogrammed software of the multi-environmental electrical voltage measuring instrument PowerLogic HDPM6000 lies in the lack of checks for the integrity of messages during transmission over communication channels. This allows attackers to exploit their privileges.

The vulnerability of the Pro-Face GP-Pro EX automation project creation software and the Pro-face Remote HMI remote monitoring software lies in the lack of checks for the integrity of messages during transmission over communication channels. Exploiting this vulnerability allows a malicious actor ...

7.3CVSS5.6AI score0.00169EPSS
Exploits0References3
CNNVD
CNNVD
added 2025/01/17 12:0 a.m.5 views

Schneider Electric Pro-face GP-Pro EX和Remote HMI 安全漏洞

Schneider Electric Pro-face GP-Pro EX and Schneider Electric Pro-face Remote HMI are both products of Schneider Electric, France.Schneider Electric Pro-face GP-Pro EX is an HMI operation management system. Schneider Electric Pro-face GP- EX is a human-machine interface operator management system,...

7.1CVSS6.6AI score0.00169EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2024/12/10 12:0 a.m.5 views

PT-2024-10223 · Pro Face · Pro-Face Remote Hmi +1

Name of the Vulnerable Software and Affected Versions: Pro-Face GP-Pro EX affected versions not specified Pro-face Remote HMI affected versions not specified Description: The issue is related to an improper enforcement of message integrity during transmission in a communication channel, which cou...

7.1CVSS6.7AI score0.00169EPSS
Exploits0References20
CNVD
CNVD
added 2023/08/14 12:0 a.m.29 views

Buffer Overflow Vulnerability in Schneider Electric Pro-face GP-Pro EX

Schneider Electric GP-Pro EX is a set of HMI interface editing and logic programming software from Schneider Electric France. A buffer overflow vulnerability exists in Schneider Electric Pro-face GP-Pro EX. The vulnerability stems from improper manipulation of restrictions within memory buffer...

5.3CVSS5.4AI score0.00168EPSS
Exploits0References1
CNVD
CNVD
added 2023/08/12 12:0 a.m.73 views

Schneider Electric GP-Pro EX is a set of HMI interface editing and logic programming software from Schneider Electric (France). A buffer overflow vulnerability exists in Schneider Electric Pro-face GP-Pro EX. The vulnerability stems from improper manipulation of restrictions within memory buffer ranges and can be exploited by an attacker to cause memory corruption.

The NETGEAR R7100LG is a router from the American company NETGEAR. A hardware device that connects two or more networks and acts as a gateway between networks. The NETGEAR R7100LG version 1.0.0.78 suffers from a command injection vulnerability that stems from the password parameter in...

7.5CVSS7.7AI score0.0071EPSS
Exploits0References1
CNNVD
CNNVD
added 2023/08/09 12:0 a.m.6 views

Schneider Electric GP-Pro EX 缓冲区错误漏洞

Schneider Electric GP-Pro EX is a set of HMI interface editing and logic programming software from Schneider Electric France. A buffer overflow vulnerability exists in Schneider Electric Pro-face GP-Pro EX. The vulnerability stems from improper manipulation of restrictions within memory buffer...

5.3CVSS7.1AI score0.00168EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2023/06/19 12:0 a.m.7 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software allows a perpetrator to execute arbitrary codes.

The vulnerability of Schneider Electric EcoStruxure Operator Terminal Expert HMI configuration software and SCADA Pro-face BLUE software is related to the possibility of code injection. Exploiting this vulnerability allows a perpetrator to execute arbitrary code by loading a specially crafted...

7.8CVSS7.6AI score0.00597EPSS
Exploits0References2Affected Software2
Positive Technologies
Positive Technologies
added 2023/06/13 12:0 a.m.13 views

PT-2023-3117 · Pro Face +1 · Pro-Face Blue +1

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Operator Terminal Expert affected versions not specified Pro-face BLUE affected versions not specified Description: A code injection vulnerability exists, potentially allowing the execution of malicious code whe...

7.8CVSS7.6AI score0.00597EPSS
Exploits0References7
BDU FSTEC
BDU FSTEC
added 2023/04/20 12:0 a.m.5 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software lies in the improper verification of the cryptographic signature. This allows a perpetrator to execute arbitrary codes.

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert and the SCADA Pro-face BLUE software is related to improper verification of the cryptographic signature. Exploiting this vulnerability allows a perpetrator to execute arbitrary code by loadin...

7CVSS7.6AI score0.00133EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/04/20 12:0 a.m.7 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software lies in the lack of security measures taken to protect the SQL query structure, allowing a hacker to execute arbitrary code.

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software is related to the lack of protective measures for the SQL query structure. Exploiting this vulnerability could allow an attacker to execute...

7CVSS7.6AI score0.0025EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/04/20 12:0 a.m.6 views

The vulnerability of the SGIUtility component in the HMI terminal configuration software for Schneider Electric EcoStruxure Operator Terminal Expert and the SCADA Pro-face BLUE software allows a malicious individual to execute arbitrary code.

The vulnerability of the SGIUtility component in Schneider Electric’s HMI terminal configuration software, as well as in the SCADA Pro-face BLUE software, is related to improper handling of a path leading to a limited catalog. Exploiting this vulnerability could allow an attacker to execute...

7CVSS7.5AI score0.00187EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/04/02 12:0 a.m.8 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software allows a perpetrator to execute arbitrary codes.

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software is related to improper project conversion. Exploiting this vulnerability could allow an attacker to execute arbitrary code...

7CVSS7.5AI score0.00197EPSS
Exploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
added 2023/04/02 12:0 a.m.9 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert HMI terminals and the SCADA Pro-face BLUE software allows a perpetrator to execute arbitrary codes.

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert and the SCADA Pro-face BLUE software is related to improper bypassing of a limited catalog. Exploiting this vulnerability can allow an attacker to execute arbitrary code...

7CVSS7.5AI score0.00215EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/03/28 12:0 a.m.7 views

The vulnerability of the SGIUtility component in the HMI terminal configuration software for Schneider Electric EcoStruxure Operator Terminal Expert and the SCADA Pro-face BLUE software allows a malicious individual to execute arbitrary code.

The vulnerability of the SGIUtility component in Schneider Electric’s HMI terminal configuration software, as well as in the SCADA Pro-face BLUE software, is related to improper verification of the cryptographic signature. Exploiting this vulnerability could allow an attacker to execute arbitrary...

7CVSS7.5AI score0.0011EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2023/03/28 12:0 a.m.22 views

The vulnerabilities of the software products for developing HMI/SCADA systems such as EcoStruxure Machine SCADA Expert and Pro-face BLUE Open Studio allow attackers to execute arbitrary code.

The vulnerability of the software products for developing HMI/SCADA systems such as EcoStruxure Machine SCADA Expert and Pro-face BLUE Open Studio is related to deficiencies in the deserialization mechanism. Exploiting this vulnerability could allow an attacker to execute arbitrary code...

7.8CVSS5.9AI score
Exploits0References2
NVD
NVD
added 2022/11/04 3:15 p.m.49 views

CVE-2022-41671

A CWE-89: Improper Neutralization of Special Elements used in SQL Command ‘SQL Injection’ vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected...

7.8CVSS0.0025EPSS
Exploits0References1
OSV
OSV
added 2022/11/04 3:15 p.m.8 views

CVE-2022-41671

A CWE-89: Improper Neutralization of Special Elements used in SQL Command ‘SQL Injection’ vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected...

7.8CVSS6AI score0.0025EPSS
Exploits0References1
Prion
Prion
added 2022/11/04 3:15 p.m.18 views

Sql injection

A CWE-89: Improper Neutralization of Special Elements used in SQL Command ‘SQL Injection’ vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected...

4.3CVSS7.9AI score0.0025EPSS
Exploits0References1Affected Software2
Rows per page