CVE-2019-11893
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...
CVE-2019-11896 Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller SHC before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...
CVE-2019-11896
CVE-2019-11896 affects the Bosch Smart Home Controller (SHC) via the 3rd-party pairing mechanism prior to version 9.8.907. The root issue is an incorrect privilege assignment that can allow a restricted app to acquire default app permissions after a successful app pairing, which requires user int...
CVE-2019-11893
The CVE-2019-11893 entry describes an incorrect privilege assignment vulnerability in the Bosch Smart Home Controller (SHC) app permission update API. Affected product: Bosch SHC prior to version 9.8.905. Vulnerable component: the app permission update API where privilege assignments can be misap...
CVE-2019-11893 Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...
CVE-2019-11891
CVE-2019-11891 affects the Bosch Smart Home Controller (SHC) prior to version 9.8.905, with an incorrect privilege assignment in the app pairing mechanism that can lead to elevated privileges. Exploitation requires physical access to the SHC. The issue is described with a high-severity impact ( c...
CVE-2019-11891 Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller SHC before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the...
CVE-2019-11896: Improper Access Control
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller SHC before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...
CVE-2019-11893: Incorrect Privilege Assignment
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller SHC before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...
CVE-2019-11891: Incorrect Privilege Assignment
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller SHC before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the...
CVE-2019-0301: Improper Privilege Management
Under certain conditions, it is possible to request the modification of role or privilege assignments through SAP Identity Management REST Interface Version 2, which would otherwise be restricted only for viewing...
CVE-2019-3843: Incorrect Privilege Assignment
It was discovered that a systemd service that uses DynamicUser property can create a SUID/SGID binary that would be allowed to run as the transient service UID/GID even after the service is terminated. A local attacker may use this flaw to access resources that will be owned by a potentially...
Zero Trust and the Case for Application Microsegmentation
Data breaches have become incessant. Recently, a very popular airline sevices company revealed a suspected breach involving customer credit card information. Even more recently, a hospital in Indiana reported that a virus had infected some of its systems that caused the hospital to be placed on...
Dialogic PowerMedia XMS Privilege Assignment Vulnerability
Dialogic PowerMedia XMS is a suite of software multimedia servers for real-time communications from Dialogic, Inc. that provide real-time multimedia communication solutions for IMS, MRF, enterprise and WebRTC applications. A privilege assignment vulnerability in Dialogic PowerMedia XMS 3.5 and...
CVE-2018-0293
A vulnerability in role-based access control RBAC for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is d...
CalAmp lenderoutlook on colt.calamp-ts.com incorrect privilege assignment vulnerability
Calamp is a pioneer in M2M telematics, managing over 1.5M IoT devices. An incorrect privilege assignment vulnerability exists in CalAmp lenderoutlook on colt.calamp-ts.com. An attacker could exploit the vulnerability to obtain sensitive data...
GE MDS PulseNET Account Java RMI Incorrect Privilege Assignment Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of GE MDS PulseNET. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the...
Calamp.com Incorrect Privilege Assignment
There is also a full write up on https://medium.com/@evstykas/remote-smart-car-hacking-with-just-a-phone-2fe7ca682162 Vulnerability Security Advisory ======================================================================= title: Incorrect Privilege Assignment product: lenderoutlook on...
Advantech WebAccess < 8.2_20170817 Multiple Vulnerabilities
Binary data scadaadvantechwebaccess8220170817.nbin...
Privilege escalation
An Incorrect Privilege Assignment issue was discovered in Advantech WebAccess versions prior to V8.220170817. A built-in user account has been granted a sensitive privilege that may allow a user to elevate to administrative privileges...